• There are no items in your cart

BS 8525-2:2011

Current
Current

The latest, up-to-date edition.

Greywater systems Domestic greywater treatment equipment. Requirements and test methods
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

08-15-2011

Foreword
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Nominal designation
5 Acceptance flow rate and acceptance volume
6 Water tightness and overflow
7 Controls and failsafe provisions
8 Treated greywater quality (based on end use application)
9 Marking and information to be supplied by the manufacturer
Annexes
Annex A (normative) - Preparation for testing
Annex B (normative) - Method of test for hydraulic functions
Annex C (normative) - Synthetic greywater for type testing
Annex D (normative) - Method of test for water quality
Annex E (informative) - Analytical methods
Annex F (informative) - Domestic greywater treatment
        equipment product information sheet
Bibliography

Defines requirements and gives methods of test for packaged and/or site-assembled domestic greywater treatment equipment.

This part of BS8525 specifies requirements and gives methods of test for packaged and/or site-assembled domestic greywater treatment equipment. This standard applies to treatment equipment where all prefabricated components are factory-or site-assembled by one manufacturer and tested as a single unit.

This part of BS8525 does not require specific water treatment processes to be used. However, it applies to equipment that treats bathroom greywater so that it is of a quality suitable for prescribed domestic uses in residential, commercial, industrial or public premises. It is not applicable to treatment equipment which processes waste from WCs and kitchens.

The test methods described in AnnexB and AnnexD have been devised for the type testing of domestic greywater treatment equipment with a nominal treatment capacity of up to 10m3 per day. They are intended to be carried out on greywater treatment equipment under controlled conditions using public mains water and synthetic greywater. These test methods are not intended for commissioning or validation of the on-site performance of the domestic greywater treatment equipment.

NOTE1 Recommendations for the installation, commissioning and validation of on-site performance of packaged and/or site-assembled domestic greywater treatment equipment as part of a greywater system are given in BS8525‑1.

NOTE2 AnnexA specifies requirements for the greywater treatment equipment test set-up and preparation; AnnexB to AnnexD specify greywater treatment equipment test methods; AnnexE and AnnexF are informative annexes, the former giving recommendations regarding analytical methods and the latter providing an example of a product information sheet.

Committee
B/505/50
DevelopmentNote
Supersedes 10/30184124 DC. (08/2011)
DocumentType
Standard
Pages
32
PublisherName
British Standards Institution
Status
Current
Supersedes

13/30259799 DC : 0 BS 8595 - CODE OF PRACTICE FOR THE STRATEGY OF WATER REUSE
BS 8595:2013 Code of practice for the selection of water reuse systems

BS EN 1899-1:1998 Water quality. Determination of biochemical oxygen demand after n days (BODn) Dilution and seeding method with allylthiourea addition
BS EN ISO 10304-1:2009 Water quality. Determination of dissolved anions by liquid chromatography of ions Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
BS EN ISO 13395:1996 Water quality. Determination of nitrite nitrogen and nitrate nitrogen and the sum of both by flow analysis (CFA and FIA) and spectrometric detection
BS EN ISO 7027:2000 Water quality. Determination of turbidity
BS EN ISO 7393-2:2000 Water quality. Determination of free chlorine and total chlorine Colorimetric method using N,N-diethyl-1,4-phenylenediamine for routine control purposes
BS EN 1085:2007 Wastewater treatment. Vocabulary
BS 6068-2.26(1986) : 1986 AMD 10870 WATER QUALITY - PHYSICAL CHEMICAL AND BIOCHEMICAL METHODS - METHOD FOR DETERMINATION OF FREE CHLORINE AND TOTAL CHLORINE COLORIMETRIC METHOD USING N N DIETHYL 1,4 PHENYLENEDIAMINE FOR CONTROL PURPOSES
BS 6068-2.34:1988 Water quality. Physical, chemical and biochemical methods Method for the determination of the chemical oxygen demand
BS EN ISO 7899-2:2000 Water quality. Detection and enumeration of intestinal enterococci in surface and waste water Membrane filtration method
BS EN ISO 9308-3:1999 Water quality. Detection and enumeration of Escherichia Coli and coliform bacteria in surface and waste water Miniaturized method (most probable number) for the detection and enumeration of $7IE. coli$7R in surface and waste water
BS 6068-2.63(1998) : 1998 WATER QUALITY - DETERMINATION OF BIOCHEMICAL OXYGEN DEMAND AFTER N DAYS (BODN) - PART 1: DILUTION AND SEEDING METHOD WITH ALLYLTHIOUREA ADDITION
BS 8525-1:2010 Greywater systems Code of practice
BS EN ISO 9308-1 : 2014 WATER QUALITY - ENUMERATION OF ESCHERICHIA COLI AND COLIFORM BACTERIA - PART 1: MEMBRANE FILTRATION METHOD FOR WATERS WITH LOW BACTERIAL BACKGROUND FLORA (ISO 9308-1:2014)
BS EN ISO 9000:2015 Quality management systems. Fundamentals and vocabulary
BS 6068-4.14(2000) : 2000 WATER QUALITY - DETECTION AND ENUMERATION OF ESCHERICHIA COLI AND COLIFORM BACTERIA - PART 1: MEMBRANE FILTRATION METHOD
BS 6068-4.10(1999) : 1999 WATER QUALITY - DETECTION AND ENUMERATION OF ESCHERICHIA COLI AND COLIFORM BACTERIA IN SURFACE AND WASTE WATER - PART 3: MINIATURIZED METHOD (MOST PROBABLE NUMBER) FOR THE DETECTION AND ENUMERATION OF E. COLI IN SURFACE AND WASTE WATER
BS EN ISO 7899-1:1999 Water quality. Detection and enumeration of intestinal enterococci in surface and waste water Miniaturized method (Most probable number) for surface and waste water

View more information
US$237.18
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.