BS 8660-1:2011

Current
Current

The latest, up-to-date edition.

Gas-fired micro-cogeneration appliances of rated thermal input not exceeding 70 kW net Specification for selection, installation, inspection, commissioning, servicing and maintenance of Stirling engine micro-cogeneration appliances
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

11-30-2011

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Competence
5 Environmental considerations
6 Selection of equipment and pre-installation
7 Installation
8 Post-installation
Annexes
Annex A (informative) - How a typical Stirling
        engine micro-cogeneration appliance works
Annex B (informative) - Matching the heat output
        of the micro-cogeneration appliance to the
        heat load of the property
Bibliography

Describes requirements for the selection, installation, inspection, commissioning, servicing and maintenance of room-sealed gas-fired Stirling engine micro-cogeneration appliances and their protection devices designed to operate in parallel with public low-voltage distribution networks.

This part of BS 8660 specifies requirements for the selection, installation, inspection, commissioning, servicing and maintenance of room-sealed gas-fired Stirling engine micro-cogeneration appliances and their protection devices designed to operate in parallel with public low-voltage distribution networks.

NOTE 1 Sometimes micro-cogeneration appliances are referred to as small-scale embedded generators (SSEG), e.g. in Engineering Recommendation G83/1/1.

NOTE 2 A room-sealed appliance is designated as Type C in PD CEN/TR 1749.

The term “micro-cogeneration appliance?? refers to equipment that:

  • is rated up to and including 16 A per phase, single or multiphase 230/400 V a.c.;

  • has a total rated heat input not exceeding 70 kW, based on net calorific value;

  • utilizes 1st, 2nd or 3rd family gases and is designed to operate in the condensing mode for the heating of domestic dwellings, including domestic dwellings in commercial premises, by the circulation of heated water in open or closed systems;

  • has been shown to meet the type verification tests in the appropriate annex of Engineering Recommendation G83/1/1;

  • carries a CE mark (see 6.2.1).

This standard does not apply to:

  • micro-cogeneration appliances with a rated input of over 70 kW;

  • groups of micro-cogeneration appliances with individual ratings of less than 70 kW with an aggregate input of greater than 70 kW.

NOTE 3 Groups of micro-cogeneration appliances with individual ratings of less than 70 kW, but with a maximum aggregate input of ≤70 kW, may be installed to this standard but specialist advice on the system design, installation and control needs to be sought from the appliance manufacturer.

It is not applicable to the detailed design and installation of the whole heating system, which is specified in BS EN 12828:2003 (incorporating corrigendum January 2009), BS EN 12831:2003 (incorporating corrigendum January 2009) and BS EN 14336:2004 (incorporating corrigendum January 2009).

NOTE 4 With the publication of BS EN 12828, BS EN 12831 and BS EN 14336, BS 5449 has been withdrawn. These standards are not aligned to UK design and installation practices; they cover commercial as well as domestic heating systems and exclude hot water. Consequently, these standards include national annexes covering all the relevant material from BS 5449.

NOTE 5 In this standard, heat input is expressed in terms of net calorific values (CV), unless stated otherwise. The ratio of gross to net heat input is approximately 1.11:1 for natural gas, 1.09:1 for propane, and 1.08:1 for butane.

NOTE 6 It is essential that persons carrying out the installation of any micro-cogeneration appliances are competent to do so. Clause 4 gives information on competence.

Committee
GSE/30
DevelopmentNote
Supersedes 10/30213917 DC. (11/2011)
DocumentType
Standard
Pages
66
PublisherName
British Standards Institution
Status
Current
Supersedes

BS PAS 2030(2012) : 2012 IMPROVING THE ENERGY EFFICIENCY OF EXISTING BUILDINGS - SPECIFICATION FOR INSTALLATION PROCESS, PROCESS MANAGEMENT AND SERVICE PROVISION

BS 1179-6:1980 Glossary of terms used in the gas industry Combustion and utilization including installation at consumers\' premises
BS 5258-8:1980 Safety of domestic gas appliances Combined appliances: gas fire/back boiler
BS 7927:1998 Heating appliances for domestic applications. Portable apparatus designed to detect and measure specific combustion flue gas products. Requirements
BS EN 1491:2000 Building valves. Expansion valves. Tests and requirements
BS 6700(2006) : 2006 DESIGN, INSTALLATION, TESTING AND MAINTENANCE OF SERVICES SUPPLYING WATER FOR DOMESTIC USE WITHIN BUILDINGS AND THEIR CURTILAGES - SPECIFICATION
BS EN 14336:2004 Heating systems in buildings. Installation and commissioning of water based heating systems
BS 7967-2:2005 Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers in the measurement of carbon monoxide and the determination of combustion performance
BS 6400-2:2006 Specification for installation, exchange, relocation and removal of gas meters with a maximum capacity not exceeding 6 m<sup>3</sup>/h Medium pressure (2nd family gases)
PD 5482-3:2005 Code of practice for domestic butane and propane gas-burning installations Installations in boats, yachts and other vessels
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
BS 6400-3:2007 Specification for installation, exchange, relocation and removal of gas meters with a maximum capacity not exceeding 6 m<sup>3</sup>/h Low and medium pressure (3rd family gases)
BS 5482-2:1977 Domestic butane- and propane-gas-burning installations Installations in caravans and non-permanent dwellings
BS 3198:1981 Specification for copper hot water storage combination units for domestic purposes
BS 6400-1:2002 Specification for installation of domestic-sized gas meters maximum rated capacity not exceeding 6 m<sup>3</sup>/h (2nd and 3rd family gases) Low pressure (2nd family gases)
BS 7860:1996 Specification for carbon monoxide detectors (electrical) for domestic use
BS EN 13831:2007 Closed expansion vessels with built-in diaphragm for installation in water
BS 3632:2005 Residential park homes. Specification
BS EN 50379-3:2012 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances
BS 5449:1990 Specification for forced circulation hot water central heating systems for domestic premises
BS EN 1443:2003 Chimneys. General requirements
CR 1472:1997 General guidance for the marking of gas appliances
BS EN 50438:2013 Requirements for micro-generating plants to be connected in parallel with public low-voltage distribution networks
BS 7967-3:2005 Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for responding to measurements obtained from electronic portable combustion gas analysers
BS EN 50291:2001 Electrical apparatus for the detection of carbon monoxide in domestic premises. Test methods and performance requirements
BS EN 1856-1:2009 Chimneys. Requirements for metal chimneys System chimney products
BS 5546:2010 Specification for installation and maintenance of gas-fired water-heating appliances of rated input not exceeding 70 kW net
BS EN 12828 : 2012 HEATING SYSTEMS IN BUILDINGS - DESIGN FOR WATER-BASED HEATING SYSTEMS
BS 1179:1967 Glossary of terms used in the gas industry
BS 7967-1:2005 Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for identifying and managing sources of fumes, smells, spillage/leakage of combustion products and carbon monoxide detector activation
BS EN 12831:2003 Heating systems in buildings. Method for calculation of the design heat load
BS 5422:2009 Method for specifying thermal insulating materials for pipes, tanks, vessels, ductwork and equipment operating within the temperature range -40°C to +700°C
PD CEN/TR 1749:2014 European scheme for the classification of gas appliances according to the method of evacuation of the combustion products (types)
BS EN ISO 4126-1 : 2013 SAFETY DEVICES FOR PROTECTION AGAINST EXCESSIVE PRESSURE - PART 1: SAFETY VALVES (ISO 4126-1:2013)
BS 5871-2:2005 Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Inset live fuel effect gas fires of heat input not exceeding 15 kW, and fire/back boilers (2nd and 3rd family gases)
BS 476-22:1987 Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction
BS 7967-4:2007 Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers as part of the process of servicing and maintenance of gas-fired appliances

View more information
US$330.61
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.