Foreword
1. GENERAL
1.1 Scope
1.2 Definitions
1.3 Exchange of information and time schedule
2. MATERIALS AND FASTENINGS
2.1 Aluminium
2.2 Underlays
2.3 Timber
2.4 Nails
2.5 Screws and bolts
3. Design considerations
3.1 Characteristics of the material
3.2 Weight of aluminium roof coverings
3.3 Substructure
3.4 Underlays
3.5 Clips
3.6 Roofing systems
3.7 Traditional standing seam and batten roll systems
3.8 Long strip system
3.9 Falls, drips and cross welts on roofs
3.10 Falls and drips in gutters
3.11 Special details and features
3.12 Condensation
3.13 Fire protection
3.14 Protection against lightning
4. LAYING PROCEDURE
4.1 Storage and protection of aluminium
4.2 Preparatory work
4.3 Underlays
4.4 Technique of laying aluminium sheeting
4.5 Cesspools
4.6 Gutters
4.7 Aprons
4.8 Main roof covering
4.9 Cover flashings
4.10 Drainage
4.11 Other building operations
5. INSPECTION AND TESTS
5.1 Materials
5.2 Substructures
5.3 Underlays
5.4 Final inspection
5.5 Maintenance
TABLES
1. Tensile strength of materials complying with the
      requirements of BS 1470 in tempers recommended for
      roofing
2. Some physical properties of 99 grade aluminium
3. Roofing sizes of strip in coil
4. Recommended tempers for aluminium of different
      purities and NS3 alloy
5. Weights of aluminium roof coverings
6. Thickness and weight of aluminium sheet and strip
7. Pitched roofs over 10 deg pitch: maximum length
      of sheet or strip
8. Flat roofs up to and including 10 deg pitch:
      maximum length of sheet or strip
9. Recommended maximum width of strip for long strip
      system
10. Recommended maximum lengths of linings for gutters
      of various sizes and widths
FIGURES
1. General layout and details of the standing seam
      system applied to flat roofs
2. General layout and details of the standing seam
      system applied to pitched roofs
3. Plain clips and expansion clips
4. Stages in forming standing seam
5. Single-lock welt
6. Double-lock welt
7. Standing seam: upstand at wall abutment
8. Detail: standing seam at ridge roll; traditional
      and long strip systems
9. Eaves detail: traditional systems
10. Verge detail: traditional and long strip systems
11. Expansion detail at eaves: long strip system
12. Detail of drip
13. General layout and details of batten roll system
      applied to flat roofs
14. General layout and details of batten roll system
      applied to pitched roofs
15. Stages in forming batten roll
16. Detail of ridge roll
17. Stages in forming batten roll at upstand
18. Gutter for slated or tiles roof
19. Gutter between slated roofs
20. Slated or tiles roof discharging on to aluminium
      flat roof
21. Aluminium roof discharging on to slated or tiled
      roof
22. Parapet gutter
23. Parapet gutter and chute or cesspool outlet
24. Detail: chimney weathering

Recommends the installation of aluminium fully supported roof and wall coverings. Includes information on appropriate alloys and forms of aluminium, durability, contact with other materials, sizes and weights of sheet and strip, protection and storage. Gutters and flashings are dealt with in so far as they form an integral part of the main roof covering. Does not apply to aluminium roof decking or deck units. Covers definitions, materials and fastenings, design considerations, laying procedure and inspection and tests. Includes several tables and figures.

Committee
B/542
DevelopmentNote
Reviewed and confirmed by BSI, November 2012. (10/2012)
DocumentType
Standard
Pages
34
PublisherName
British Standards Institution
Status
Current

BS 6229:1982 Code of practice for flat roofs with continuously supported coverings
13/30274184 DC : 0 BS 5918 - SOLAR HEATING SYSTEMS FOR DOMESTIC HOT WATER - CODE OF PRACTICE
BS 8118-2(1991) : 1991 STRUCTURAL USE OF ALUMINIUM - PART 2: SPECIFICATION FOR MATERIALS, WORKMANSHIP AND PROTECTION
BS 6229:2003 Flat roofs with continuously supported coverings. Code of practice
BS 747:1994 Specification for roofing felts
BS 747:1977 Specification for roofing felts
BS 747:2000 Reinforced bitumen sheets for roofing. Specification
BS 8118-1:1991 STRUCTURAL USE OF ALUMINUM - CODE OF PRACTICE FOR DESIGN

BS 1202-3:1974 Specification for nails Aluminium nails
BS 5268-5:1977 Code of practice for the structural use of timber Preservative treatments for constructional timber
BS 1202-1:1974 Specification for nails Specifications for nails. Steel nails
BS 747:1968 Specification for roofing felts
BS CP3:CH5-2(1972) : AMD 7908 CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - LOADING - WIND LOADS
BS 4011:1966 Recommendations for the co-ordination of dimensions in building. Co-ordinating sizes for building components and assemblies
BS 2717:1956 Glossary of terms applicable to roof coverings
BS 913:1973 Specification for wood preservation by means of pressure creosoting
BS PD6444-1(1969) : LATEST RECOMMENDATIONS FOR THE COORDINATION OF DIMENSIONS IN BUILDING
BS 6432:1984 Methods for determining properties of glass fibre reinforced cement material
BS CP3:CH5-1(1967) : LATEST CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - LOADING - DEAD AND IMPOSED LOADS
BS CP326(1965) : LATEST THE PROTECTION OF STRUCTURES AGAINST LIGHTNING
BS 4330:1968 Recommendations for the co-ordination of dimensions in building. Controlling dimensions
BS CP112-2(1971) : AMD 3278 CODE OF PRACTICE FOR THE STRUCTURAL USE OF TIMBER - METRIC UNITS

View more information
US$261.13
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.