Pumps. Rotodynamic pumps. Circulation pumps having a rated power input not exceeding 200 W for heating installations and domestic hot water installations Non-automatic circulation pumps, requirements, testing, marking
Available format(s)

Hardcopy , PDF

Superseded date

11-30-2012

Language(s)

English

Published date

01-31-2008

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and units
5 Performance and safety requirements
  5.1 Hydraulic characteristic
  5.2 Rated power
  5.3 Starting characteristics
  5.4 Resistance to internal pressure
  5.5 Temperature resistance
  5.6 Resistance to thermal cycling
  5.7 Venting and deblocking
  5.8 Material- and design requirement
  5.9 Fluid and structure borne noise emission
6 Test methods
  6.1 General
  6.2 Testing of the hydraulic characteristic
      6.2.1 General
      6.2.2 Test conditions
      6.2.3 Testing of hydraulic performance
  6.3 Measurement of rated power input
  6.4 Starting conditions
  6.5 Testing of resistance to internal pressure
  6.6 Testing of temperature resistance
  6.7 Testing of resistance to thermal cycling
      6.7.1 Motor supply voltage
      6.7.2 Intermittent operation
  6.8 Venting and deblocking
  6.9 Toxicity, biological and microbiological test
7 Information for use
  7.1 General
  7.2 Instruction handbook
  7.3 Marking
Annex A (informative) Additives
Bibliography

Defines general principles for the construction, use and testing of circulation pumps of the glandless type, having a rated power input P[1] less than or equal to 200 W, intended to be used in heating installations and domestic hot water service installations.

Committee
MCE/6
DevelopmentNote
Supersedes BS EN 1151 & 03/317581 DC. (05/2006)
DocumentType
Standard
Pages
20
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

BS 6700(2006) : 2006 DESIGN, INSTALLATION, TESTING AND MAINTENANCE OF SERVICES SUPPLYING WATER FOR DOMESTIC USE WITHIN BUILDINGS AND THEIR CURTILAGES - SPECIFICATION
EN 14336:2004 Heating systems in buildings - Installation and commissioning of water based heating systems
BS EN 14336:2004 Heating systems in buildings. Installation and commissioning of water based heating systems

EN 1151-2:2006/AC:2007 PUMPS - ROTODYNAMIC PUMPS - CIRCULATION PUMPS HAVING A RATED POWER INPUT NOT EXCEEDING 200 W FOR HEATING INSTALLATIONS AND DOMESTIC HOT WATER INSTALLATIONS - PART 2: NOISE TEST CODE (VIBRO-ACOUSTICS) FOR MEASURING STRUCTURE- AND FLUID-BORNE NOISE
VDI 2035:1979-07 Prevention of damage by means of corrosion and scale formation in warm-water-heating-systems
EN 60034-1:2010/corrigendum Oct. 2010 ROTATING ELECTRICAL MACHINES - PART 1: RATING AND PERFORMANCE
DIN 4751-2:1994-10 MEDIUM TEMPERATURE HOT WATER SYSTEMS (MTHWS) WITH A BOILER FLOW TEMPERATURE UP TO 120 DEG C - SPECIFICATION FOR SEALED SYSTEMS USING THERMOSTATIC CONTROL - SAFETY EQUIPMENT
HD 472 S1:1989/AC:2013 NOMINAL VOLTAGES FOR LOW-VOLTAGE PUBLIC ELECTRICITY SUPPLY SYSTEMS
IEC 60335-2-51:2002+AMD1:2008+AMD2:2011 CSV Household and similar electrical appliances - Safety - Part 2-51: Particular requirements for stationary circulation pumps for heating and service water installations
EN 60335-2-51:2003/A2:2012 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-51: PARTICULAR REQUIREMENTS FOR STATIONARY CIRCULATION PUMPS FOR HEATING AND SERVICE WATER INSTALLATIONS (IEC 60335-2-51:2002/A2:2011)
EN ISO 12100-1:2003/A1:2009 SAFETY OF MACHINERY - BASIC CONCEPTS, GENERAL PRINCIPLES FOR DESIGN - PART 1: BASIC TERMINOLOGY, METHODOLOGY
EN 809 : 1998 COR 2010 PUMPS AND PUMP UNITS FOR LIQUIDS - COMMON SAFETY REQUIREMENTS
DIN 4751-3:1993-02 MEDIUM TEMPERATURE HOT WATER SYSTEMS (MTHWS) WITH A BOILER FLOW TEMPERATURE UP TO 95 DEGREE C AND FORCED FLOW BOILERS WITH RATED OUTPUT UP TO 50 KW - SPECIFICATION FOR SEALED SYSTEMS USING THERMOSTATIC CONTROL - SAFETY EQUIPMENT
BS 5449:1990 Specification for forced circulation hot water central heating systems for domestic premises
ISO 12100-2:2003 Safety of machinery Basic concepts, general principles for design Part 2: Technical principles
IEC 60034-1:2017 Rotating electrical machines - Part 1: Rating and performance
EN ISO 12100-2:2003/A1:2009 SAFETY OF MACHINERY - BASIC CONCEPTS, GENERAL PRINCIPLES FOR DESIGN - PART 2: TECHNICAL PRINCIPLES
ISO 12100-1:2003 Safety of machinery Basic concepts, general principles for design Part 1: Basic terminology, methodology
DIN 4751-1:1994-10 MEDIUM TEMPERATURE HOT WATER SYSTEMS (MTHWS) WITH A BOILER FLOW TEMPERATURE UP TO 120 DEGREE C - SPECIFICATION FOR OPEN SYSTEMS AND SEALED SYSTEMS WITH PRESSURISATION BY GRAVITY USING A COLUMN OF WATER OR BY SAFETY VALVES - SAFETY EQUIPMENT

View more information
US$170.10
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.