BS EN 50091-1-2:1999
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
General and safety requirements for UPS used in restricted access locationsSpecification for uninterruptible power systems (UPS)
Hardcopy , PDF
10-26-2018
English
04-15-2000
Foreword
1 General
1.1 Scope
1.2 Normative references
1.3 Definitions
1.4 General requirements
1.5 General conditions for tests
1.6 Components
1.7 Power interfaces
1.8 Marking and instructions
2 Fundamental design requirements
2.1 Protection against electric shock and energy hazards
2.2 Insulation
2.3 Safety Extra-Low Voltage (SELV) Circuits
2.4 Limited current circuits
2.5 Provisions for protective earthing
2.6 A.C. and d.c. power isolation
2.7 Overcurrent and earth fault protection
2.8 Protection of service personnel
2.9 Clearances, creepage distances and distances through
insulation
2.10 External signalling circuits
2.11 Limited power source
2.12 Protection of the applied load
2.13 Connection to other equipment
3 Wiring, connections and supply
3.1 General
3.2 Connection to power sources
3.3 Wiring terminals for external power conductors
4 Physical requirements
4.1 Stability and mechanical hazards
4.2 Mechanical strength and stress relief
4.3 Construction details
4.4 Resistance to fire
4.5 Battery location
5 Thermal and electrical requirements
5.1 Heating
5.2 Earth leakage current
5.3 Electric strength
5.4 Abnormal operating and fault conditions
Annexes
A (normative) Test for resistance to heat and fire
B (normative) Motor test under abnormal conditions
C (normative) Transformers
D (normative) Measuring instruments for earth
leakage current test
E (normative) Temperature rise of a winding
F (normative) Measurements of creepage
G (normative) Earth leakage current for UPS intended
to be connected directly to IT power systems
H (informative) Guidance on protection against ingress
of water and foreign objects
J (informative) Tables of electrochemical potentials
K (normative) Thermal controls
L (normative) Backfeed protection test
M (normative) Reference load conditions
N (normative) Ventilation of battery compartments
P (normative) Minimum and maximum cross-sections
Q (informative) A-Deviations
R (normative) Special national conditions