1 General
   1.1 Scope
   1.2 Normative references
2 Definitions
3 General requirements
4 Normal and special service conditions
5 Ratings
   5.1 Standard values of rated voltages
   5.2 Standard values of rated output
   5.3 Standard values of rated voltage factor
   5.4 Limits of temperature rise
6 Design requirements
   6.1 Insulation requirements
   6.2 Short-circuit withstand capability
7 Classification of tests
8 Type tests
   8.1 Temperature-rise tests
   8.2 Short-circuit withstand capability test
   8.3 Impulse test on primary winding
   8.4 Wet test for outdoor type transformers
9 Routine tests
   9.1 Verification of terminal markings
   9.2 Power frequency tests on primary winding and partial
        discharge measurement
   9.3 Power-frequency tests between section and on secondary
        windings
10 Special test
11 Markings
   11.1 Rating plate and markings
   11.2 Terminal markings
12 Accuracy requirements for three-phase inductive measuring
   voltage transformers
   12.1 Accuracy class designation for measuring voltage
        transformers
   12.2 Limits of voltage error and phase displacement for
        measuring voltage transformers
   12.3 Type test for accuracy of measuring voltage transformers
   12.4 Routine test for accuracy of measuring voltage transformers
   12.5 Markings of the rating plate of three-phase measuring
        voltage transformer
13 Additional requirements for three-phase inductive protective
   voltage transformers
   13.1 Accuracy class designation for protective voltage
        transformers
   13.2 Limits of voltage error and phase displacement for
        protective voltage transformers
   13.3 Rated voltages for secondary windings intended to produce a
        residual voltage
   13.4 Output for secondary windings intended to produce a residual
        voltage
   13.5 Accuracy class for secondary windings intended to produce a
        residual voltage
   13.6 Type test for protective voltage transformers
   13.7 Routine test for protective transformers
   13.8 Markings of the rating plate of a three-phase protective
        voltage transformer
Bibliography

Defines the requirements and tests for new three-phase voltage transformers with U[m] up to 52 kV and frequencies from 15 Hz to 100 Hz, for use with electrical instruments or electrical protective devices.

Committee
PEL/38
DevelopmentNote
Supersedes BS 7729(1994). (06/2008)
DocumentType
Standard
Pages
24
PublisherName
British Standards Institution
Status
Withdrawn
Supersedes

Standards Relationship
EN 50482:2008 Identical

EN 60044-2:1999/A2:2003 INSTRUMENT TRANSFORMERS - PART 2: INDUCTIVE VOLTAGE TRANSFORMERS
IEC 60038:2009 IEC standard voltages
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 60044-2:1997+AMD1:2000+AMD2:2002 CSV Instrument transformers - Part 2 : Inductive voltage transformers
HD 588.1 : S1 AMD 1 HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS
EN 60270:2001/A1:2016 HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015)
EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules

View more information
US$237.18
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.