BS EN 61076-3-104:2017
Current
The latest, up-to-date edition.
Hardcopy , PDF
English
10-24-2017
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Technical information
4 Dimensional information
5 Characteristics
6 Test schedule
Annex A (normative) - Gauging procedure
Annex B (normative) - Locking device mechanical
operation - test procedure and requirements
Annex C (normative) - Plug and outlet interoperability
qualification
Annex D (normative) - General requirements for
the measurement set-up
Annex E (normative) - Insertion loss
Annex F (normative) - Return loss
Annex G (normative) - Near end cross talk (NEXT)
Annex H (normative) - Far end cross talk (FEXT)
Annex I (normative) - Transverse Conversion Loss
(TCL) and Transverse Conversion
Transfer Loss (TCTL)
Annex J (normative) - Termination of balun
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines uniform specifications, type testing requirements for 8-way, shielded free and fixed connectors for data transmissions with frequencies up to 2000 MHz, and used as category 7[A] connectors in class F[A] cabling systems specified in ISO/IEC 11801-1.
IEC 61076-3-104:2017(E) establishes uniform specifications, type testing requirements for 8 way, shielded free and fixed connectors for data transmissions with frequencies up to 2 000 MHz, and used as category 7A connectors in class FA cabling systems specified in ISO/IEC 11801-1. It contains all test methods and sequences, severity and preferred values for dimensions and characteristics.
This third edition of IEC 61076-3-104 cancels and replaces the second edition, published in 2006, and constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- the title has been changed to incorporate transmissions with frequencies up to 2 000 MHz;
- the drawings of some styles have been corrected for clarification;
- Figures 23 and 24 have been updated;
- Figure 3 has been updated to include reference dimensions and dimensional format changes;
- the dimensions of Figure 7 have been updated;
- the type designation and ordering information has been removed for consistency with the most updated sectional specification;
- the test schedule was updated to include appropriate IEC 60512 Test Nos;
- the electrical performance requirements have been revised for 2 GHz level and interchangeability information has been added for performance categories.
Committee |
EPL/48
|
DevelopmentNote |
Supersedes 00/203906 DC (10/2003) Supersedes 04/30112325 DC (12/2006) Supersedes 12/30270756 DC. (11/2017)
|
DocumentType |
Standard
|
Pages |
92
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
SN EN 61076-3-104 : 2003 | Identical |
DIN EN 61076-3-104 : 2007 | Identical |
IEC 61076-3-104:2017 | Identical |
I.S. EN 61076-3-104:2017 | Identical |
EN 61076-3-104:2017 | Identical |
DEFSTAN 21-88(PT4)/4(2012) : 2012 | POLICIES AND PROCEDURES FOR SYSTEM INTEGRATION IN SURFACE SHIPS - PART 4: LEGACY PLATFORM DEDICATED INTERFACES |
DEFSTAN 21-88/2(2006) : 2006 | POLICIES AND PROCEDURES FOR COMBAT SYSTEM INTEGRATION IN SURFACE SHIPS (SSP 88) |
IEC 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
EN 60352-2:2006/A1:2013 | SOLDERLESS CONNECTIONS - PART 2: CRIMPED CONNECTIONS - GENERAL REQUIREMENTS, TEST METHODS AND PRACTICAL GUIDANCE |
IEC 60352-3:1993 | Solderless connections - Part 3: Solderless accessible insulation displacement connections - General requirements, test methods and practical guidance |
IEC 60512-11-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-4: Climatic tests - Test 11d: Rapid change of temperature |
IEC 60352-6:1997 | Solderless connections - Part 6: Insulation piercing connections - General requirements, test methods and practical guidance |
IEC 60512-3-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 3-1: Insulation tests - Test 3a: Insulation resistance |
IEC 61076-3:2008 | Connectors for electronic equipment - Product requirements - Part 3: Rectangular connectors - Sectional specification |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 62153-4-12:2009 | Metallic communication cable test methods - Part 4-12: Electromagnetic compatibility (EMC) - Coupling attenuation or screening attenuation of connecting hardware - Absorbing clamp method |
IEC 60512-9-2:2011 | Connectors for electronic equipment - Tests and measurements - Part 9-2: Endurance tests - Test 9b: Electrical load and temperature |
IEC 61156-9:2016 | Multicore and symmetrical pair/quad cables for digital communications - Part 9: Cables for channels with transmission characteristics up to 2 GHz - Sectional specification |
EN 60352-3:1994 | Solderless connections - Part 3: Solderless accessible insulation displacement connections - General requirements, test methods and practical guidance |
EN 60512-15-6:2008 | Connectors for electronic equipment - Tests and measurements - Part 15-6: Connector tests (mechanical) - Test 15f: Effectiveness of connector coupling devices |
EN ISO 1302 : 2002 | GEOMETRICAL PRODUCT SPECIFICATIONS (GPS) - INDICATION OF SURFACE TEXTURE IN TECHNICAL PRODUCT DOCUMENTATION (ISO 1302:2002) |
EN 60512-26-100:2008/A1:2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 26-100: MEASUREMENT SETUP, TEST AND REFERENCE ARRANGEMENTS AND MEASUREMENTS FOR CONNECTORS ACCORDING TO IEC 60603-7 - TESTS 26A TO 26G |
IEC 61156-10:2016 | Multicore and symmetrical pair/quad cables for digital communications - Part 10: Cables for cords with transmission characteristics up to 2 GHz - Sectional specification |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
IEC 60512-13-2:2006 | Connectors for electronic equipment - Tests and measurements - Part 13-2: Mechanical operation tests - Test 13b: Insertion and withdrawal forces |
EN 60352-6:1997 | Solderless connections - Part 6: Insulation piercing connections - General requirements, test methods and practical guidance |
IEC 60512-2-5:2003 | Connectors for electronic equipment - Tests and measurements - Part 2-5: Electrical continuity and contact resistance tests - Test 2e: Contact disturbance |
EN 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
EN 60512-6-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-4: Dynamic stress tests - Test 6d: Vibration (sinusoidal) |
IEC 60068-2-38:2009 | Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test |
EN 60512-13-2 : 2006 COR 2006 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 13-2: MECHANICAL OPERATION TESTS - TEST 13B: INSERTION AND WITHDRAWAL FORCES |
EN 60352-5:2012/AC:2014 | SOLDERLESS CONNECTIONS - PART 5: PRESS-IN CONNECTIONS - GENERAL REQUIREMENTS, TEST METHODS AND PRACTICAL GUIDANCE (IEC 60352-5:2012) |
ISO 1302:2002 | Geometrical Product Specifications (GPS) Indication of surface texture in technical product documentation |
IEC 60512-26-100:2008+AMD1:2011 CSV | Connectors for electronic equipment - Tests and measurements - Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 - Tests 26a to 26g |
EN 60512-11-7:2003 | Connectors for electronic equipment - Tests and measurements - Part 11- 7: Climatic tests - Test 11g: Flowing mixed gas corrosion test |
IEC 61156-2:2010 | Multicore and symmetrical pair/quad cables for digital communications - Part 2: Symmetrical pair/quad cables with transmission characteristics up to 100 MHz - Horizontal floor wiring - Sectional specification |
EN 60512-1-2:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-2: General examination - Test 1b: Examination of dimension and mass |
EN 60512-9-2:2012 | Connectors for electronic equipment - Tests and measurements - Part 9-2: Endurance tests - Test 9b: Electrical load and temperature |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
IEC 60512-1-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination |
IEC 60352-5:2012 | Solderless connections - Part 5: Press-in connections - General requirements, test methods and practical guidance |
IEC 60512-2-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method |
IEC 60512-9-1:2010 | Connectors for electronic equipment - Tests and measurements - Part 9-1: Endurance tests - Test 9a: Mechanical operation |
IEC 60512-11-7:2003 | Connectors for electronic equipment - Tests and measurements - Part 11-7: Climatic tests - Test 11g: Flowing mixed gas corrosion test |
EN 60512-3-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 3-1: Insulation tests - Test 3a: Insulation resistance |
EN 60512-2-5:2003 | Connectors for electronic equipment - Tests and measurements - Part 2-5: Electrical continuity and contact resistance tests - Test 2e: Contact disturbance |
IEC 61156-7:2003+AMD1:2012 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 7: Symmetrical pair cables with transmissioncharacteristics up to 1 200 MHz - Sectional specification fordigital and analog communication cables |
IEC 60512-4-1:2003 | Connectors for electronic equipment - Tests and measurements - Part 4-1: Voltage stress tests - Test 4a: Voltage proof |
IEC 61156-6:2010+AMD1:2012 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 6: Symmetrical pair/quad cables withtransmission characteristics up to 1 000 MHz - Work area wiring -Sectional specification |
IEC 60352-2:2006+AMD1:2013 CSV | Solderless connections - Part 2: Crimped connections - Generalrequirements, test methods and practical guidance |
EN 60352-4:1994/A1:2000 | SOLDERLESS CONNECTIONS - PART 4: SOLDERLESS NON-ACCESSIBLE INSULATION DISPLACEMENT CONNECTIONS - GENERAL REQUIREMENTS, TEST METHODS AND PRACTICAL GUIDANCE |
IEC 61156-5:2009+AMD1:2012 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 5: Symmetrical pair/quad cables withtransmission characteristics up to 1 000 MHz - Horizontal floorwiring - Sectional specification |
IEC 61156-4:2009 | Multicore and symmetrical pair/quad cables for digital communications - Part 4: Riser cables - Sectional specification |
IEC 61156-3:2008 | Multicore and symmetrical pair/quad cables for digital communications - Part 3: Work area cable - Sectional specification |
EN 60512-4-1:2003 | Connectors for electronic equipment - Tests and measurements - Part 4-1: Voltage stress tests - Test 4a: Voltage proof |
EN 61076-3:2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3: RECTANGULAR CONNECTORS - SECTIONAL SPECIFICATION |
EN 60352-7:2002 | Solderless connections - Part 7: Spring clamp connections - General requirements, test methods and practical guidance |
EN 60512-1-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination |
IEC 60512-6-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-4: Dynamic stress tests - Test 6d: Vibration (sinusoidal) |
EN 60512-28-100:2013 | Connectors for electronic equipment - Tests and measurements - Part 28-100: Signal integrity tests up to 1 000 MHz on IEC 60603-7 and IEC 61076-3 series connectors - Tests 28a to 28g |
EN 50289-1-14:2004 | Communication cables - Specifications for test methods - Part 1-14: Electrical test methods - Coupling attenuation or screening attenuation of connecting hardware |
IEC 60512-15-6:2008 | Connectors for electronic equipment - Tests and measurements - Part 15-6: Connector tests (mechanical) - Test 15f: Effectiveness of connector coupling devices |
IEC 60512-25-9:2008 | Connectors for electronic equipment - Tests and measurements - Part 25-9: Signal integrity tests - Test 25i: Alien crosstalk |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60512-1-2:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-2: General examination - Test 1b: Examination of dimension and mass |
EN 60512-9-1 : 2010 | Connectors for electronic equipment - Tests and measurements - Part 9-1: Endurance tests - Test 9a: Mechanical operation |
IEC 60352-7:2002 | Solderless connections - Part 7: Spring clamp connections - General requirements, test methods and practical guidance |
EN 60512-11-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-4: Climatic tests - Test 11d: Rapid change of temperature |
EN 60512-2-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.