• There are no items in your cart

BS EN 61334-5-1:2001

Current
Current

The latest, up-to-date edition.

Distribution automation using distribution line carrier systems. Lower layer profiles The spread frequency shift keying (S-FSK) profile
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

10-17-2001

FOREWORD
1 General
   1.1 Scope and object
   1.2 Normative references
   1.3 Definitions
2 Modulation
   2.1 Purpose
   2.2 Spread frequency shift keying (S-FSK) principle
   2.3 Spreading
   2.4 Performance tests
       2.4.1 Purpose
       2.4.2 White noise BER tests
       2.4.3 Narrowband interferer BER tests
       2.4.4 Impulsive noise BER tests
3 Physical layer
   3.1 Purpose
   3.2 Transmission method
       3.2.1 Coding
       3.2.2 Bit timing
       3.2.3 Frame timing
       3.2.4 Slot timing
   3.3 Packet encapsulation
       3.3.1 Purpose
       3.3.2 Byte and bit ordering
       3.3.3 Preamble and start subframe delimiter
       3.3.4 Pause
   3.4 Physical layer services definitions
       3.4.1 General description
       3.4.2 P_Data.request
       3.4.3 P_Data.confirm
       3.4.4 P_Data.indication
       3.4.5 P_Sync.request
       3.4.6 P_Sync.indication
   3.5 Sending and receiving physical sublayer
       3.5.1 Sending
       3.5.2 Receiving
       3.5.3 Synchronization - desynchronization of a server
       3.5.4 Physical state transition tables
       3.5.5 Transition table description
4 Medium access control sublayer (MAC)
   4.1 MAC service specification
       4.1.1 Purpose
       4.1.2 Characteristics
       4.1.3 Overview of the services
       4.1.4 MA_Data.request
       4.1.5 MA_Data.confirm
       4.1.6 MA_Data.indication
       4.1.7 MA_Sync.indication
   4.2 MAC frame structure
       4.2.1 Frame indicator
       4.2.2 Long MAC frame format
       4.2.3 Elements of the long MAC frame
       4.2.4 Invalid long MAC frame
   4.3 Medium access control method
       4.3.1 Functional model
       4.3.2 Transmission description
       4.3.3 Reception description
       4.3.4 MAC management description
       4.3.5 Formal specification
       4.3.6 Medium access state table
       4.3.7 Transition table description
Annex A (normative) Description of error values
Annex ZA (normative) Normative references to international
         publications with their corresponding European publications
Bibliography

Defines the requirements of S-SFK (frequency shift keying modulation) in conjunction with the services provided by the physical layer entity and the MAC sublayer. The transmission medium is supposed to be the distribution network on both MV or LV level.

Describes the requirements of S-FSK (frequency shift keying modulation) in conjunction with the services provided by the physical layer entity and the MAC sublayer. The transmission medium is assumed to be the distribution network on both MV or LV level. To be used in conjunction with IEC 61334-4-32.

This publication is of high relevance for Smart Grid.

Committee
PEL/57
DevelopmentNote
Supersedes BS IEC 61334-5-1 Also numbered as IEC 61334-5-1 (11/2001)
DocumentType
Standard
Pages
66
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
I.S. EN 61334-5-1:2001 Identical
SN EN 61334-5-1 : 2001 Identical
EN 61334-5-1:2001 Identical
NF EN 61334-5-1 : 2001 Identical
DIN EN 61334-5-1:2001-12 Identical

ISO/IEC 7498-3:1997 Information technology Open Systems Interconnection Basic Reference Model: Naming and addressing
ISO/IEC 7498-1:1994 Information technology Open Systems Interconnection Basic Reference Model: The Basic Model
IEC TR 61334-1-4:1995 Distribution automation using distribution line carrier systems - Part 1: General considerations - Section 4: Identification of data transmission parameters concerning medium and low-voltage distribution mains
IEC 61334-4-32:1996 Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 32: Data link layer - Logical link control (LLC)
EN 61334-4-511:2000 Distribution automation using distribution line carrier systems - Part 4-511: Data communication protocols - Systems management - CIASE protocol
IEC 61334-4-511:2000 Distribution automation using distribution line carrier systems - Part 4-511: Data communication protocols - Systems management - CIASE protocol
EN 61334-4-1:1996 Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 1: Reference model of the communication system
EN 61334-4-32 : 1996 Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 32: Data link layer - Logical link control (LLC)
EN 50065-1:2011 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 1: General requirements, frequency bands and electromagnetic disturbances
IEC 61334-4-1:1996 Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 1: Reference model of the communication system
IEC 61334-4-512:2001 Distribution automation using distribution line carrier systems - Part 4-512: Data communication protocols - System management using profile 61334-5-1 - Management Information Base (MIB)

View more information
US$330.61
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.