BS EN 80601-2-30 : 2010

Current
Current

The latest, up-to-date edition.

MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2010

FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing ME EQUIPMENT
201.6 Classification of ME EQUIPMENT and ME SYSTEMS
201.7 ME EQUIPMENT identification, marking and documents
201.8 Protection against electrical HAZARDS from ME EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS of ME EQUIPMENT
        and ME SYSTEMS
201.10 Protection against unwanted and excessive radiation
        HAZARDS
201.11 Protection against excessive temperatures and other
        HAZARDS
201.12 Accuracy of controls and instruments and protection
        against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT and ME
        SYSTEMS
201.101 Requirements for CUFFS
201.102 Connection tubing and CUFF connectors
201.103 Unauthorized access
201.104 Maximum inflating time
201.105 Automatic cycling modes
201.106 Clinical accuracy
202 Electromagnetic compatibility - Requirements and tests
206 Usability
211 Requirement for MEDICAL ELECTRICAL EQUPIMENT and MEDICAL
        LECTRICAL SYSTEMS used in the HOME HEALTHCARE ENVIROMENT
Annexes
Annex C (informative) - Guide to marking and labelling requirements
        for ME EQUIPMENT and ME SYSTEMS
Annex AA (informative) - Particular guidance and rationale
Annex BB (informative) - Environmental aspects
Annex CC (informative) - Reference to the essential principles
Bibliography
Index of defined terms
Annex ZA (normative) - Normative references to international
         publications with their corresponding European publications
Annex ZZ (informative) - Coverage of Essential Requirements of
         EC Directives

Pertains to the BASIC SAFETY and ESSENTIAL PERFORMANCE of AUTOMATED SPHYGMOMANOMETERS, hereafter referred to as ME EQUIPMENT, which by means of an inflatable CUFF, are used for non-continuous indirect measurement of the BLOOD PRESSURE without arterial puncture.

Committee
CH/62/4
DevelopmentNote
Supersedes BS EN 60601-2-30 & 06/30159274 DC. (11/2010) 2010 Edition Re-Issued in July 2015 & incorporates AMD 1 2015. 2010 Edition remains current and will be withdrawn on 14/04/2018. (07/2015)
DocumentType
Standard
Pages
60
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
IEC 80601-2-30:2009+AMD1:2013 CSV Identical
EN 80601-2-30:2010/A1:2015 Identical

IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
ISO 81060-1:2007 Non-invasive sphygmomanometers — Part 1: Requirements and test methods for non-automated measurement type
IEC 60601-1-6:2010+AMD1:2013 CSV Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability
EN 60068-2-64:2008 ENVIRONMENTAL TESTING - PART 2-64: TESTS - TEST FH: VIBRATION, BROADBAND RANDOM AND GUIDANCE
EN 60601-1-6:2010/A1:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 1-6: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: USABILITY (IEC 60601-1-6:2010/A1:2013)
IEC 60601-1-8:2006+AMD1:2012 CSV Medical electrical equipment - Part 1-8: General requirements forbasic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems inmedical electrical equipment and medical electrical systems
IEC 60068-2-31:2008 Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
IEC 60068-2-64:2008 Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
IEC 62366:2007+AMD1:2014 CSV Medical devices - Application of usability engineering to medical devices
ISO 21647:2004 Medical electrical equipment Particular requirements for the basic safety and essential performance of respiratory gas monitors
IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
EN 60601-1-2:2015 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60601-2-2:2017 Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
CR 13825:2000 Luer connectors - A report to CEN chef from the CEN forum task group "Luer fittings"
EN ISO 21647:2009 Medical electrical equipment - Particular requirements for the basic safety and essential performance of respiratory gas monitors (ISO 21647:2004, including Cor 1:2005)
ISO/TR 16142:2006 Medical devices Guidance on the selection of standards in support of recognized essential principles of safety and performance of medical devices
ISO 81060-2:2013 Non-invasive sphygmomanometers Part 2: Clinical investigation of automated measurement type
EN 62366 : 2008 AMD 1 2015 MEDICAL DEVICES - APPLICATION OF USABILITY ENGINEERING TO MEDICAL DEVICES (IEC 62366:2007/A1:2014)
ISO 9919:2005 Medical electrical equipment Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use
ISO 594-2:1998 Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 2: Lock fittings
EN 20594-1:1993/A1:1997 CONICAL FITTINGS WITH A 6% (LUER) TAPER FOR SYRINGES, NEEDLES AND CERTAIN OTHER MEDICAL EQUIPMENT - GENERAL REQUIREMENTS
ISO 594-1:1986 Conical fittings with a 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 1: General requirements
EN 60601-1-11:2015 Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
EN ISO 9919:2009 Medical electrical equipment - Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use (ISO 9919:2005)
EN 60601-1-8:2007/A11:2017 MEDICAL ELECTRICAL EQUIPMENT - PART 1-8: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: GENERAL REQUIREMENTS, TESTS AND GUIDANCE FOR ALARM SYSTEMS IN MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS (IEC 60601-1-8:2006/A1:2012)
EN 60068-2-31:2008 ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS

View more information
US$311.44
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.