Anaesthetic gas monitors

Available format(s)

Hardcopy , PDF

Superseded date

12-06-2004

Language(s)

English

Published date

10-15-1997

Section 1 General
    1.1 Scope
    1.2 Normative references
    1.3 Definitions
    1.4 General requirements and general requirements
          for tests
    1.5 Classification
    1.6 Identification, marking and documents
    1.7 Power input
Section 2 Environmental conditions
    2.1 Basic safety categories
    2.2 Removable protective means
    2.3 Environmental conditions
Section 3 Protection against electric shock hazards
    3.1 General
    3.2 Requirements related to classification
    3.3 Limitation of voltage and/or energy
    3.4 Enclosures and protective covers
    3.5 Separation
    3.6 Protective earthing, functional earthing and
          potential equalization
    3.7 Continuous leakage current and patient auxiliary
          currents
    3.8 Dielectric strength
Section 4 Protection against mechanical hazards
    4.1 Mechanical strength
    4.2 Moving parts
    4.3 Surface, corners and edges
    4.4 Stability in normal use
    4.5 Expelled parts
    4.6 Vibration and noise
    4.7 Pneumatic and hydraulic power
    4.8 Suspended masses
Section 5 Protection against hazards from unwanted or
excessive radiation
    5.1 X-radiation
    5.2 Alpha, beta, gamma, neutron radiation and other
          particle radiation
    5.3 Microwave radiation
    5.4 Light radiation (including lasers)
    5.5 Infrared radiation
    5.6 Ultraviolet radiation
    5.7 Acoustical energy (including ultrasonics)
    5.8 Electromagnetic compatibility
Section 6 Protection against hazards of ignition of
flammable anaesthetic mixtures
    6.1 Locations and basic requirements
    6.2 Marking, accompanying documents
    6.3 Common requirements for categories AP and APG
          equipment
    6.4 Requirements and tests for category AP equipment,
          parts and components
    6.5 Requirements and tests for category APG equipment,
          parts and components
Section 7 Protection against excessive temperatures and
other safety hazards
    7.1 Excessive temperatures
    7.2 Fire prevention
    7.3 Overflow, spillage, leakage, humidity, ingress of
          liquids, cleaning, sterilization and disinfection
    7.4 Pressure vessels and parts subject to pressure
    7.5 Human errors
    7.6 Electrostatic charges
    7.7 Materials in applied parts in contact with body
          of patient
    7.8 Interruption of power supply
Section 8 Accuracy of operating data and protection against
hazardous output
    8.1 Accuracy of operating data
    8.2 Protection against hazardous output
Section 9 Abnormal operation and fault conditions:
environmental tests
    9.1 Abnormal operation and fault conditions
    9.2 Environmental tests
Section 10 Constructional requirements
    10.1 General
    10.2 Enclosures and covers
    10.3 Components and general assembly
    10.4 Main parts, components and layout
    10.5 Protective earthing - Terminals and connections
    10.6 Construction and layout
Section 11 Additional requirements specific to anaesthetic
gas monitors
    11.1 Interfering gas and vapour effects (other than
          water vapour)
    11.2 Obstruction of sampling tube
    11.3 Breathing system connections
    11.4 Contamination of breathing systems
Annexes
A to L
M Test of anaesthetic agents for non-flammability
N Rationale
P Bibliography

Defines requirements for anaesthetic gas monitors to be used in determination of the anaesthetic vapour and/or gas level(s) in breathing gas mixtures. Covers both diverting and non-diverting gas monitors, whichever measuring technology is used. Includes anaesthetic gas mixtures identifying monitors, and monitoring of patient breathing mixtures, output of anaesthesia workstations, output of vaporizers in addition to anaesthesia ventilators and breathing systems. Does not cover anaesthetic gas monitors for laboratory research, non-human use or for calibrating anaesthetic agent vaporizers.

Committee
EPL/100
DevelopmentNote
Supersedes 93/500391 DC. (03/2007)
DocumentType
Standard
Pages
38
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

ISO 9703-1:1992 Anaesthesia and respiratory care alarm signals Part 1: Visual alarm signals
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
ISO 5356-1:2015 Anaesthetic and respiratory equipment Conical connectors Part 1: Cones and sockets
ISO 32:1977 Gas cylinders for medical use — Marking for identification of content
IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
ISO 5359:2014 Anaesthetic and respiratory equipment Low-pressure hose assemblies for use with medical gases
IEC 60079-3:1990 Electrical apparatus for explosive gas atmospheres - Part 3: Spark-test apparatus for intrinsically-safe circuits
ISO 4135:2001 Anaesthetic and respiratory equipment Vocabulary
ISO 9703-2:1994 Anaesthesia and respiratory care alarm signals — Part 2: Auditory alarm signals
IEC 60801-2:1991 Electromagnetic compatibility for industrial-process measurement and control equipment - Part 2: Electrostatic discharge requirements

View more information
US$277.90
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.