• There are no items in your cart

BS EN ISO 1452-3:2010

Current

Current

The latest, up-to-date edition.

Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure. Unplasticized poly(vinyl chloride) (PVC-U) Fittings

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

08-31-2015

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviated
   terms
4 Material
5 General characteristics
6 Geometrical characteristics
7 Classification and operating conditions
8 Mechanical characteristics
9 Physical characteristics
10 Sealing rings
11 Adhesives
12 Performance requirements
13 Marking
Annex A (normative) - Imperial(inch)-sized fittings
Bibliography

Describes the characteristics of fittings made from unplasticized poly(vinyl chloride) (PVC-U) for piping systems intended for water supply and for buried and above-ground drainage and sewerage under pressure.

This part of ISO1452 specifies the characteristics of fittings made from unplasticized poly(vinyl chloride) (PVC-U) for piping systems intended for water supply and for buried and above-ground drainage and sewerage under pressure. It also specifies the test parameters for the test methods referred to in this part of ISO1452 . In conjunction with ISO1452‑1 , ISO1452‑2 and ISO1452‑5 , it is applicable to PVC-U fittings and to joints with components of PVC-U, other plastics and non-plastics materials intended to be used for the following: water mains and services buried in the ground; conveyance of water above ground for both outside and inside buildings; buried and above-ground drainage and sewerage under pressure. It is applicable to fittings in piping systems intended for the supply of water under pressure up to and including 25°C (cold water), intended for human consumption and for general purposes as well as for waste water under pressure. This part of ISO1452 is also applicable to components for the conveyance of water and waste water up to and including 45°C. For temperatures between 25°C and 45°C, FigureA.1 of ISO1452‑2:2009 applies. NOTE1 The producer and the end-user can come to agreement on the possibilities of use for temperatures above 45°C on a case-by-case basis. Depending on the jointing method, this part of ISO1452 is applicable to the following types of fittings: fittings for solvent cementing; elastomeric ring seal fittings. PVC-U fittings can be manufactured by injection-moulding and/or be fabricated from pipe. This part of ISO1452 is also applicable to PVC-U flange adapters and to the corresponding flanges made from various materials. This part of ISO1452 covers a range of fitting sizes and pressure classes and gives requirements concerning colours. NOTE2 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.

Committee
PRI/88/2
DevelopmentNote
Supersedes 08/30168684 DC. (01/2010) Together with BS EN ISO 1452-1, BS EN ISO 1452-2, BS EN ISO 1452-4 & BS EN ISO 1452-5, it supersedes BS EN 1452-1, BS EN 1452-2, BS EN 1452-3, BS EN 1452-4, BS EN 1452-5 & BS EN 1456-1. (04/2010) Supersedes 10/30228627 DC. (02/2012)
DocumentType
Standard
Pages
48
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
ISO 1452-3:2009 Identical
EN ISO 1452-3:2010 Identical

11/30228295 DC : 0 BS 8558 - GUIDE TO THE DESIGN, INSTALLATION, TESTING, OPERATION AND MAINTENANCE OF SERVICES SUPPLYING WATER FOR DOMESTIC USE WITHIN BUILDINGS AND THEIR CURTILAGES - COMPLEMENTARY GUIDANCE TO BS EN 806
BS 8558:2015 Guide to the design, installation, testing and maintenance of services supplying water for domestic use within buildings and their curtilages. Complementary guidance to BS EN 806
BS 8558:2011 Guide to the design, installation, testing and maintenance of services supplying water for domestic use within buildings and their curtilages. Complementary guidance to BS EN 806
15/30299694 DC : 0 BS 8558 - GUIDE TO THE DESIGN, INSTALLATION, TESTING AND MAINTENANCE OF SERVICES SUPPLYING WATER FOR DOMESTIC USE WITHIN BUILDINGS AND THEIR CURTILAGES - COMPLEMENTARY GUIDANCE TO BS EN 806

ISO 580:2005 Plastics piping and ducting systems — Injection-moulded thermoplastics fittings — Methods for visually assessing the effects of heating
ISO 2507-2:1995 Thermoplastics pipes and fittings — Vicat softening temperature — Part 2: Test conditions for unplasticized poly(vinyl chloride) (PVC-U) or chlorinated poly(vinyl chloride) (PVC-C) pipes and fittings and for high impact resistance poly (vinyl chloride) (PVC-HI) pipes
ISO 2507-1:1995 Thermoplastics pipes and fittings — Vicat softening temperature — Part 1: General test method
ISO 1452-1:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC-U) Part 1: General
ISO 1452-5:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC-U) Part 5: Fitness for purpose of the system
ENV 1452-7:2000 Plastics piping systems for water supply - Unplasticized poly(vinyl chloride) (PVC-U) - Part 7: Guidance for the assessment of conformity
CEN/TR 15438:2007 Plastics piping systems - Guidance for coding of products and their intended uses
EN 802:1994 Plastics piping and ducting systems - Injection-moulded thermoplastics fittings for pressure piping systems - Test method for maximum deformation by crushing
ISO 3126:2005 Plastics piping systems Plastics components Determination of dimensions
ISO 13783:1997 Plastics piping systems — Unplasticized poly(vinyl chloride) (PVC-U) end-load-bearing double-socket joints — Test method for leaktightness and strength while subjected to bending and internal pressure
ISO 7-1:1994 Pipe threads where pressure-tight joints are made on the threads Part 1: Dimensions, tolerances and designation
ISO 1452-2:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC-U) Part 2: Pipes
ISO 1167-3:2007 Thermoplastics pipes, fittings and assemblies for the conveyance of fluids Determination of the resistance to internal pressure Part 3: Preparation of components
ISO 1183-1:2012 Plastics Methods for determining the density of non-cellular plastics Part 1: Immersion method, liquid pyknometer method and titration method
ISO/TR 4191:2014 Plastics piping systems for water supply Unplasticized poly(vinyl chloride)(PVC-U) and oriented PVC-U (PVC-O) Guidance for installation
ISO 7686:2005 Plastics pipes and fittings — Determination of opacity
ISO 1167-1:2006 Thermoplastics pipes, fittings and assemblies for the conveyance of fluids Determination of the resistance to internal pressure Part 1: General method

View more information
US$313.84
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.