Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radiofrequency fields (Adopted IEC 61000-4-6:2013, fourth edition, 2013-10) | Compatibilité électromagnétique (CEM) - Partie 4-6 : Techniques d\'essai et de mesure - Immunité aux perturbations conduites, induites par les champs radioélectriques (norme IEC 61000-4-6:2013 adoptée, quatrième édition, 2013-10)

Available format(s)

PDF , Hardcopy

Language(s)

English - French, English

Published date

01-01-2015

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Test levels
6 Test equipment and level adjustment procedures
7 Test setup and injection methods
8 Test procedure
9 Evaluation of the test results
10 Test report
Annex A (normative) - EM and decoupling clamps
Annex B (informative) - Selection criteria for the frequency
        range of application
Annex C (informative) - Guide for selecting test levels
Annex D (informative) - Information on coupling and
        decoupling networks
Annex E (informative) - Information for the test generator
        specification
Annex F (informative) - Test setup for large EUTs
Annex G (informative) - Measurement uncertainty of the
        voltage test level
Annex H (informative) - Measurement of AE impedance
Annex I (informative) - Port to port injection
Annex J (informative) - Amplifier compression and non-linearity
Bibliography

CSA Preface This is the third edition of CAN/CSA-IEC 61000-4-6, Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radiofrequency fields, which is an adoption without modification of the identically titled IEC (International Electrotechnical Commission) Standard 61000-4-6 (fourth edition, 2013-10). It supersedes the previous edition published in 2009 as CAN/CSA-C61000-4-6 (adopted IEC 61000-4-6:2003+A1:2004+A2:2006). Scope This part of IEC 61000 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150 kHz up to 80 MHz. Equipment not having at least one conducting wire and/or cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded from the scope of this publication. NOTE 1 Test methods are defined in this part of IEC 61000 to assess the effect that conducted disturbing signals, induced by electromagnetic radiation, have on the equipment concerned. The simulation and measurement of these conducted disturbances are not adequately exact for the quantitative determination of effects. The test methods defined are structured for the primary objective of establishing adequate repeatability of results at various facilities for quantitative analysis of effects. The object of this standard is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by RF fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. NOTE 2 As described in IEC Guide 107, this standard is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. ---------------------------------------------------------------------------------- Préface CSA Ce document constitue la troisième édition de la CAN/CSA-IEC 61000-4-6, Compatibilité électromagnétique (CEM) - Partie 4-6 : Techniques d\'essai et de mesure - Immunité aux perturbations conduites, induites par les champs radioélectriques. Il s\'agit de l\'adoption, sans modifications, de la norme IEC Commission Électrotechnique Internationale) 61000-4-6 (quatrième édition, 2013-10) qui porte le même titre. Cette norme remplace l\'édition antérieure publiée en 2009 qui portait la désignation CAN/CSA-C61000-4-6 (norme IEC 61000-4-:2003+A1:2004+A2:2006 adoptée). Domaine d\'application La présente partie de la CEI 61000 se rapporte aux exigences relatives à l\'immunité en conduction des matériels électriques et électroniques aux perturbations électromagnétiques provoquées par des émetteurs destinés à des radiofréquences (RF), dans la gamme de fréquences de 150 kHz à 80 MHz. Les matériels n\'ayant pas au moins un câble conducteur (par exemple, cordons d\'alimentation, lignes de transmission de signaux ou connexions de mise à la terre) capable de coupler les matériels aux champs RF perturbateurs ne sont pas concernés par la présente norme. NOTE 1 Les méthodes d\'essai sont définies dans la présente partie de la CEI 61000 pour mesurer l\'effet que les signaux perturbateurs conduits, induits par le rayonnement électromagnétique, ont sur l\'équipement concerné. La simulation et la mesure de ces perturbations conduites ne sont pas parfaitement exactes pour la détermination quantitative des effets. Les méthodes d\'essai définies sont structurées dans le but principal d\'établir une bonne reproductibilité des résultats dans des installations différentes en vue de l\'analyse quantitative des effets. L\'objet de la présente norme est d\'établir une référence commune dans le but d\'évaluer l\'immunité fonctionnelle des matériels électriques et électroniques, quand ils sont soumis aux perturbations conduites induites par les champs radiofréquence. La méthode d\'essai documentée dans cette partie de la CEI 61000, décrit une méthode cohérente dans le but d\'évaluer l\'immunité d\'un matériel ou d\'un système vis-à-vis d\'un phénomène défini. NOTE 2 Comme décrit dans le Guide 107 de la CEI, la présente norme est une publication fondamentale en CEM destinée à être utilisée par les comités de produits de la CEI. Comme indiqué également dans le Guide 107, il incombe aux comités de produits de la CEI de déterminer s\'il convient d\'appliquer ou non la présente Norme d\'essai d\'immunité, et si tel est le cas, ils ont la responsabilité de déterminer les niveaux d\'essai et les critères de performance appropriés.

CSA Preface This is the third edition of CAN/CSA-IEC 61000-4-6, Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radiofrequency fields, which is an adoption without modification of the identically titled IEC (International Electrotechnical Commission) Standard 61000-4-6 (fourth edition, 2013-10). It supersedes the previous edition published in 2009 as CAN/CSA-C61000-4-6 (adopted IEC 61000-4-6:2003+A1:2004+A2:2006). Scope This part of IEC 61000 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150 kHz up to 80 MHz. Equipment not having at least one conducting wire and/or cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded from the scope of this publication. NOTE 1 Test methods are defined in this part of IEC 61000 to assess the effect that conducted disturbing signals, induced by electromagnetic radiation, have on the equipment concerned. The simulation and measurement of these conducted disturbances are not adequately exact for the quantitative determination of effects. The test methods defined are structured for the primary objective of establishing adequate repeatability of results at various facilities for quantitative analysis of effects. The object of this standard is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by RF fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. NOTE 2 As described in IEC Guide 107, this standard is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. ---------------------------------------------------------------------------------- Préface CSA Ce document constitue la troisième édition de la CAN/CSA-IEC 61000-4-6, Compatibilité électromagnétique (CEM) - Partie 4-6 : Techniques d\'essai et de mesure - Immunité aux perturbations conduites, induites par les champs radioélectriques. Il s\'agit de l\'adoption, sans modifications, de la norme IEC Commission Électrotechnique Internationale) 61000-4-6 (quatrième édition, 2013-10) qui porte le même titre. Cette norme remplace l\'édition antérieure publiée en 2009 qui portait la désignation CAN/CSA-C61000-4-6 (norme IEC 61000-4-:2003+A1:2004+A2:2006 adoptée). Domaine d\'application La présente partie de la CEI 61000 se rapporte aux exigences relatives à l\'immunité en conduction des matériels électriques et électroniques aux perturbations électromagnétiques provoquées par des émetteurs destinés à des radiofréquences (RF), dans la gamme de fréquences de 150 kHz à 80 MHz. Les matériels n\'ayant pas au moins un câble conducteur (par exemple, cordons d\'alimentation, lignes de transmission de signaux ou connexions de mise à la terre) capable de coupler les matériels aux champs RF perturbateurs ne sont pas concernés par la présente norme. NOTE 1 Les méthodes d\'essai sont définies dans la présente partie de la CEI 61000 pour mesurer l\'effet que les signaux perturbateurs conduits, induits par le rayonnement électromagnétique, ont sur l\'équipement concerné. La simulation et la mesure de ces perturbations conduites ne sont pas parfaitement exactes pour la détermination quantitative des effets. Les méthodes d\'essai définies sont structurées dans le but principal d\'établir une bonne reproductibilité des résultats dans des installations différentes en vue de l\'analyse quantitative des effets. L\'objet de la présente norme est d\'établir une référence commune dans le but d\'évaluer l\'immunité fonctionnelle des matériels électriques et électroniques, quand ils sont soumis aux perturbations conduites induites par les champs radiofréquence. La méthode d\'essai documentée dans cette partie de la CEI 61000, décrit une méthode cohérente dans le but d\'évaluer l\'immunité d\'un matériel ou d\'un système vis-à-vis d\'un phénomène défini. NOTE 2 Comme décrit dans le Guide 107 de la CEI, la présente norme est une publication fondamentale en CEM destinée à être utilisée par les comités de produits de la CEI. Comme indiqué également dans le Guide 107, il incombe aux comités de produits de la CEI de déterminer s\'il convient d\'appliquer ou non la présente Norme d\'essai d\'immunité, et si tel est le cas, ils ont la responsabilité de déterminer les niveaux d\'essai et les critères de performance appropriés.

DevelopmentNote
Supersedes CSA C61000-4-6. (05/2015)
DocumentType
Standard
ISBN
978-1-77139-995-1
Pages
0
PublisherName
Canadian Standards Association
Status
Current
Supersedes

Standards Relationship
IEC 61000-4-6 : 4.0 Identical
IEC 61000-4-6:2013 Identical

CAN/CSA-CISPR 32:17 Electromagnetic compatibility of multimedia equipment — Emission requirements (Adopted IEC CISPR 32:2015, second edition, 2015-03, with Canadian deviations) | Compatibilité électromagnétique des équipements multimédia — Exigences d’émission (norme IEC CISPR 32:2015 adoptée, deuxième édition, 2015-03, avec exigences propres au Canada)

CISPR 20:2006+AMD1:2013 CSV Sound and television broadcast receivers and associated equipment -Immunity characteristics - Limits and methods of measurement
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements
IEC TR 61000-1-6:2012 Electromagnetic compatibility (EMC) - Part 1-6: General - Guide to the assessment of measurement uncertainty
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

View more information
US$290.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.