INDUSTRIAL, SCIENTIFIC AND MEDICAL EQUIPMENT - RADIO-FREQUENCY DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT
Available format(s)

Hardcopy , PDF

Withdrawn date

11-01-2018

Language(s)

English - Italian

Published date

01-01-2017

European foreword
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Frequencies designated for ISM use
5 Classification of equipment
6 Limits of electromagnetic disturbances
7 Measurement requirements
8 Special provisions for test site measurements (9 kHz to
   1 GHz)
9 Radiation measurements: 1 GHz to 18 GHz
10 Measurement in situ
11 Safety precautions for emission measurements on ISM RF
   equipment
12 Measurement uncertainty
Annex A (informative) - Examples of equipment classification
Annex B (informative) - Precautions to be taken in the use of a
        spectrum analyzer
Annex C (normative) - Measurement of electromagnetic radiation
        disturbance in the presence of signals from radio
        transmitters
Annex D (informative) - Propagation of interference from
        industrial radio-frequency equipment at frequencies
        between 30 MHz and 300 MHz
Annex E (informative) - Recommendations of CISPR for
        protection of certain radio services in particular
        areas
Annex F (informative) - Frequency bands allocated for
        safety-related radio services
Annex G (informative) - Frequency bands allocated for
        sensitive radio services
Annex H (informative) - Statistical assessment of series
        produced equipment against the requirements
        of CISPR standards
Annex I (normative) - Artificial Network (AN) for the
        assessment of disturbance voltages at d.c. power
        ports of semiconductor power converters
Annex J (informative) - Measurements on Grid Connected
        Power Converters (GCPC) - Setups for an effective
        test site configuration
Annex K (informative) - Test site configuration and
        instrumentation - Guidance on prevention of
        saturation effects in mitigation filters of
        transformer-less power converters during
        type tests according to this standard
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications
Annex ZB (normative) - Frequencies designated on a national
         basis in CENELEC countries for use as fundamental
         ISM frequencies
Annex ZZ (informative) - Coverage of Essential Requirements
         of EU Directives
Bibliography

Pertains to industrial, scientific and medical electrical equipment operating in the frequency range 0 Hz to 400 GHz and to domestic and similar appliances designed to generate and/or use locally radio-frequency energy.

Committee
CT 210
DevelopmentNote
Classificazione CEI 110-6 (08/2001) 5ED 2013 Edition is valid until 15-02-2019. (02/2017)
DocumentType
Standard
Pages
102
PublisherName
Comitato Elettrotecnico Italiano
Status
Withdrawn
SupersededBy

CEI 64-8/5 : 2012 LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 5: ERECTION AND SELECTION OF ELECTRICAL EQUIPMENT
UNI 10566 : 2013 ELECTROFUSION WELDING MACHINES AND AUXILIARY EQUIPMENT FOR POLYETHYLENE PIPES AND/OR FITTING JOINTS BY ELECTROWELDABLE CONNECTIONS FOR GAS, WATER AND OTHERS PRESSURE FLUIDS PIPELINES CONSTRUCTION, TEST AND MAINTENANCE REQUIREMENTS, DOCUMENTATION

CISPR 14-1:2016 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
EN 62135-2:2015 Resistance welding equipment - Part 2: Electromagnetic compatibility (EMC) requirements
CISPR 16-4-2:2011+AMD1:2014 CSV Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
EN 55016-2-3:2017 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
EN 55016-1-4:2010/A2:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017)
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements
IEC 61689:2013 Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz
CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
IEC 60364-5-51:2005 Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
CISPR 16-2-1:2014 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
IEC 61922:2002 High-frequency induction heating installations - Test methods for the determination of power output of the generator
CISPR 15:2013+AMD1:2015 CSV Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
IEC 60974-10:2014+AMD1:2015 CSV Arc welding equipment - Part 10: Electromagnetic compatibility (EMC)requirements
IEC 60364-1:2005 Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions
IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
EN 60601-1-2:2015 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60601-2-2:2017 Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories
IEC 61308:2005 High-frequency dielectric heating installations - Test methods for the determination of power output
EN 61307:2011 Industrial microwave heating installations - Test methods for the determination of power output
IEC 62135-2:2015 Resistance welding equipment - Part 2: Electromagnetic compatibility (EMC) requirements
CISPR 16-2-3:2016 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
EN 60974-10:2014/A1:2015 ARC WELDING EQUIPMENT - PART 10: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS (IEC 60974-10:2014/A1:2015)
CEI 62-11 : 1ED 1983 APPARECCHI ELETTROMEDICALI. NORME PARTICOLARI DI SICUREZZA PER GLI APPARECCHI DI ELETTROCHIRURGIA AD ALTA FREQUENZA
IEC 61307:2011 Industrial microwave heating installations - Test methods for the determination of power output
EN 55016-2-1:2014/A1:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 2-1: METHODS OF MEASUREMENT OF DISTURBANCES AND IMMUNITY - CONDUCTED DISTURBANCE MEASUREMENTS (CISPR 16-2-1:2014/A1:2017)
IEC 60705:2010+AMD1:2014 CSV Household microwave ovens - Methods for measuring performance
EN 55016-1-1:2010/A2:2014 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014)

View more information
US$239.95
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.