DIN EN 61663-2 : 2002

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

LIGHTNING PROTECTION - TELECOMMUNICATION LINES - PART 2: LINES USING METALLIC CONDUCTORS

Withdrawn date

11-30-2022

Published date

01-12-2013

FOREWORD
INTRODUCTION
Clause
1 Scope and object
2 Normative references
3 Definitions
4 Reference configuration
5 Environmental factor Ke, installation factor Ki,
  shielding factor Ks and conventional transition
  point length LcT
  5.1 Environmental factor Ke
  5.2 Installation factor Ki
  5.3 Shielding factor Ks
  5.4 Conventional transition point length LcT
6 Protection need
  6.1 General
  6.2 Protection need against indirect lightning to
      the telecommunication line
  6.3 Protection need against direct lightning to the
      structure that the telecommunication line enters
  6.4 Protection need against direct lightning to the
      telecommunication line
7 Protection measures
  7.1 General
  7.2 Protective measures against indirect lightning
      to the telecommunication line
  7.3 Protective measures against direct lightning to
      the structure that the telecommunication line enters
  7.4 Protective measures against direct lightning to
      the telecommunication lines
Annex A (normative) Procedure for evaluating the
        protection needs against lightning of
        telecommunication or signal lines using
        metallic conductors
Annex B (normative) Resistance value of the cable shield
        connection to earth along the telecommunication
        line
Annex C (normative) Evaluation of the lightning current
        I striking the structure which causes damage
        to the telecommunication line entering the structure
Annex D (informative) Overvoltages, overcurrents and
        frequency of damage Fp on a telecommunication line
Annex E (informative) Relative amount of expected
        losses per damage
Annex F (informative) Application of protection need
        requirements: examples
Annex G (informative) Environmental factor Ke
Annex H (informative) Risk of damage Rp
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications

Pertains to protection against lightning of outdoor telecommunication lines using metallic conductors (for example, access networks, lines between buildings). It aims to protect telecommunication lines and connected equipment against the direct and indirect influence of lightning by limiting the risk of damage due to overvoltages and overcurrents, liable to occur in these lines, to values which are lower than or equal to the tolerable risk of damage.

DocumentType
Standard
PublisherName
Verband Deutscher Elektrotechniker
Status
Withdrawn

Standards Relationship
NBN EN 61663-2 : 2001 Identical
NF EN 61663-2 : 2001 Identical
VDE 0845-4-2 : 2002 Corresponds
BS EN 61663-2:2001 Identical
EN 61663-2 : 2001 Identical
I.S. EN 61663-2:2001 Identical
UNE-EN 61663-2:2003 Identical
IEC 61663-2:2001 Identical
VDE 0845-4-2 : 2002 Identical

DIN 56950-1 E : 2012 ENTERTAINMENT TECHNOLOGY - MACHINERY INSTALLATIONS - PART 1: SAFETY REQUIREMENTS AND INSPECTION
DIN EN 61663-1 : 2000 LIGHTNING PROTECTION - TELECOMMUNICATION LINES - PART 1: FIBRE OPTIC INSTALLATIONS
VDE 0845-4-1 : 2000 LIGHTING PROTECTION - TELECOMMUNICATION LINES - FIBRE OPTIC INSTALLATIONS A FIBRES OPTIQUES
DIN 56950-1:2012-05 ENTERTAINMENT TECHNOLOGY - MACHINERY INSTALLATIONS - PART 1: SAFETY REQUIREMENTS AND INSPECTIONS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.