MODEL CODE OF SAFE PRACTICE - PART 15: AREA CLASSIFICATION FOR INSTALLATIONS HANDLING FLAMMABLE FLUIDS
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

07-01-2015

Foreword
Key technical changes
Acknowledgements
Overview
1 Introduction
2 The technique of area classification
3 The point source approach for classification of individual
  sources of release
4 Effect of ventilation on area classification
Annexes
Annex A - Classification and categorisation of petroleum and
          flammable fluids
Annex B - Area classification for hydrogen
Annex C - Calculation of hazard radii
Annex D - The direct example approach for classification of common
          facilities in open areas
Annex E - Small-scale operations (laboratories and pilot plants)
Annex F - Background and examples on ventilation of enclosed areas,
          releases within enclosed areas and associated external
          hazardous areas
Annex G - Glossary
Annex H - References

This Model Code gives guidance on the classification of areas around equipment handling or storing flammable fluids, and provides a basis for both the correct selection of fixed electrical equipment and the location of other sources of ignition in those areas.

DocumentType
Standard
ISBN
9780852937174
Pages
169
PublisherName
Energy Institute (formerly Institute of Petroleum - IP)
Status
Current
Supersedes

BS EN ISO 15138:2007 Petroleum and natural gas industries. Offshore production installations. Heating, ventilation and air-conditioning
NFPA 497 : 2017 CLASSIFICATION OF FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS
I.S. EN ISO 15138:2007 PETROLEUM AND NATURAL GAS INDUSTRIES - OFFSHORE PRODUCTION INSTALLATIONS - HEATING, VENTILATION AND AIR-CONDITIONING
C22.1-15 PACKAGE Consists of C22.1-15, Canadian electrical code, part I (23rd edition), safety standard for electrical installations; C22.1HB-15, Canadian electrical code handbook - an explanation of rules of the Canadian electrical code, part I and the 2015 Electrical quick reference
C22.1HB-18 Canadian Electrical Code Handbook - An Explanation of the Rules of the Canadian Electrical Code, Part I
EI 1560 : 2013 RECOMMENDED PRACTICE FOR THE OPERATION, INSPECTION, MAINTENANCE AND COMMISSIONING OF AVIATION FUEL HYDRANT SYSTEMS AND HYDRANT SYSTEM EXTENSIONS
EI 1592 : 2017 DESIGN, FUNCTIONAL REQUIREMENTS AND LABORATORY TESTING PROTOCOLS FOR ELECTRONIC BULK WATER DETECTORS FOR USE IN AVIATION FUELLING
CSA CE CODE SAFETY PACKAGE : 2012 CE CODE SAFETY PACKAGE
C22.10-10 Québec Construction Code, Chapter V - Electricity Canadian Electrical Code, Part I (Twenty-first Edition) with Québec Amendments
EEMUA 159 : 2014 ABOVE GROUND FLAT BOTTOMED STORAGE TANKS - A GUIDE TO INSPECTION, MAINTENANCE AND REPAIR
BS 5908-1:2012 Fire and explosion precautions at premises handling flammable gases, liquids and dusts Code of practice for precautions against fire and explosion in chemical plants, chemical storage and similar premises
EN ISO 15138:2007 Petroleum and natural gas industries - Offshore production installations - Heating, ventilation and air-conditioning (ISO 15138:2007)
EI RR. AVIATION FUEL. HAZA. AREA CLASS. : 2017 EI RESEARCH REPORT - AVIATION FUELLING HAZARDOUS AREA CLASSIFICATION
EI MODEL CODE SAFE PRACTICE PT1 : 2010 THE SELECTION, INSTALLATION, INSPECTION, AND MAINTENANCE OF ELECTRICAL AND NON ELECTRICAL APPARATUS IN HAZARDOUS AREAS
EI 1598 : 2012 DESIGN, FUNCTIONAL REQUIREMENTS AND LABORATORY TESTING PROTOCOLS FOR ELECTRONIC SENSORS TO MONITOR FREE WATER AND/OR PARTICULATE MATTER IN AVIATION FUEL
EI 1540 : 2014 DESIGN, CONSTRUCTION, COMMISSIONING, MAINTENANCE AND TESTING OF AVIATION FUELLING FACILITIES
EI MODEL CODE SAFE PRACTICE PT7 : 1998 DESIGN, CONSTRUCTION, OPERATION AND MAINTENANCE OF AVIATION FUELLING FACILITIES
EI Model Code of Safe Practice Part 16:2017 MODEL CODE OF SAFE PRACTICE - PART 16: GUIDANCE ON TANK CLEANING
EI TP PETROLEUM ROAD TANKER : 2010 PETROLEUM ROAD TANKER DESIGN AND CONSTRUCTION
C22.1-18 Canadian Electrical Code, Part I (24th Edition), Safety Standard for Electrical Installations

EI Model Code of Safe Practice Part 11:2005 BITUMEN SAFETY CODE
IEC 60079-1:2014 RLV Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
BS EN 60079-19 : 2011 EXPLOSIVE ATMOSPHERES - PART 19: EQUIPMENT REPAIR, OVERHAUL AND RECLAMATION
IEC 60079-10:2002 Electrical apparatus for explosive gas atmospheres - Part 10: Classification of hazardous areas
ISO 15649:2001 Petroleum and natural gas industries — Piping
BS EN 676 : 2003 AUTOMATIC FORCED DRAUGHT BURNERS FOR GASEOUS FUELS
PD CLC/TR 50404:2003 Electrostatics. Code of practice for the avoidance of hazards due to static electricity
PD CLC/TR 50427:2004 Assessment of inadvertent ignition of flammable atmospheres by radio-frequency radiation. Guide
IEC TR 60079-20:1996 Electrical apparatus for explosive gas atmospheres - Part 20: Data for flammable gases and vapours, relating to the use of electrical apparatus
BS EN 50272-1:2010 Safety requirements for secondary batteries and battery installations General safety information
IEC 60079-19:2010+AMD1:2015 CSV Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation
IEC 60079-17:2013 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
BS EN 1834-1:2000 Reciprocating internal combustion engines. Safety requirements for design and construction of engines for use in potentially explosive atmospheres Group II engines for use in flammable gas and vapour atmospheres
EI Model Code of Safe Practice Part 16:2017 MODEL CODE OF SAFE PRACTICE - PART 16: GUIDANCE ON TANK CLEANING
BS EN 746-2:2010 Industrial thermoprocessing equipment Safety requirements for combustion and fuel handling systems
IEC 60079-18:2014 RLV Explosive atmospheres - Part 18: Equipment protection by encapsulation “m”
IEC 61892-7:2014 Mobile and fixed offshore units - Electrical installations - Part 7: Hazardous areas
BS EN 60079-15:2010 Explosive atmospheres Equipment protection by type of protection \'n\'
BS EN 60079-6:2007 Explosive atmospheres Equipment protected by oil immersion \'o\'
BS EN 60079-18 : 2015 EXPLOSIVE ATMOSPHERES - PART 18: EQUIPMENT PROTECTION BY ENCAPSULATION 'M'
BS EN 1755:2015 Industrial Trucks. Safety requirements and verification. Supplementary requirements for operation in potentially explosive atmospheres
IEC 61892-5:2014 Mobile and fixed offshore units - Electrical installations - Part 5: Mobile units
BS EN 60079-2:2014 Explosive atmospheres Equipment protection by pressurized enclosure \'p\'
IEC 60079-5:2015 RLV Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
BS EN 60079-5:2015 Explosive atmospheres Equipment protection by powder filling \'q\'
API 521 : 2014 PRESSURE-RELIEVING AND DEPRESSURING SYSTEMS
BS EN 60079-7 : 2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015)
IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IMO IA811 : 2001 MOBILE OFFSHORE DRILLING UNITS (MODU) CODE, CONSOLIDATED
BS EN 60079-29-1:2007 Explosive atmospheres Gas detectors. Performance requirements of detectors for flammable gases
BS EN 60079-17:2014 Explosive atmospheres Electrical installations inspection and maintenance
IEC 61892-3:2012 Mobile and fixed offshore units - Electrical installations - Part 3: Equipment
ISO 21789:2009 Gas turbine applications — Safety
BS EN 60079-26:2015 Explosive atmospheres Equipment with Equipment Protection Level (EPL) Ga
EI MODEL CODE SAFE PRACTICE PT2 : 3ED 2013 DESIGN, CONSTRUCTION AND OPERATION OF PETROLEUM DISTRIBUTION INSTALLATIONS
EI MODEL CODE SAFE PRACTICE PT1 : 2010 THE SELECTION, INSTALLATION, INSPECTION, AND MAINTENANCE OF ELECTRICAL AND NON ELECTRICAL APPARATUS IN HAZARDOUS AREAS
BS EN 161 : 2011 AUTOMATIC SHUT-OFF VALVES FOR GAS BURNERS AND GAS APPLIANCES
IEC 61892-1:2015 Mobile and fixed offshore units - Electrical installations - Part 1: General requirements and conditions
IEC 60079-6:2015 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
IEC 60092-502:1999 Electrical installations in ships - Part 502: Tankers - Special features
IEC 60079-14:2013 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
BS EN 60079-11:2012 Explosive atmospheres Equipment protection by intrinsic safety \'i\'
IEC 61892-6:2013 Mobile and fixed offshore units - Electrical installations - Part 6: Installation
IEC TR 60079-12:1978 Electrical apparatus for explosive gas atmospheres - Part 12:Classification of mixtures of gases of vapours with air accordingto their maximum experimental safe gaps and minimum ignitingcurrents
BS EN 1834-2:2000 Reciprocating internal combustion engines. Safety requirements for design and construction of engines for use in potentially explosive atmospheres Group I engines for use in underground workings susceptible to firedamp and/or combustible dust
BS EN 60079-0 : 2012 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
BS EN 1643:2014 Safety and control devices for gas burners and gas burning appliances. Valve proving systems for automatic shut-off valves
EI MODEL CODE SAFE PRACTICE PT19 : 2012 FIRE PRECAUTIONS AT PETROLEUM REFINERIES AND BULK STORAGE INSTALLATIONS
IEC 60623:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
IP STANDARD METHODS : 76ED 2017 IP STANDARD TEST METHODS FOR ANALYSIS AND TESTING OF PETROLEUM AND RELATED PRODUCTS, AND BRITISH STANDARD 2000 PARTS, 2017
ISO 13702:2015 Petroleum and natural gas industries — Control and mitigation of fires and explosions on offshore production installations — Requirements and guidelines
IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
IEC 60079-26:2014 RLV Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga
EI MODEL CODE SAFE PRACTICE PT21 : 3ED 2013 MODEL CODE OF SAFE PRACTICE - PART 21: GUIDELINES FOR THE CONTROL OF HAZARDS ARISING FROM STATIC ELECTRICITY
EI BLUE BOOK : 3ED 2011 DESIGN, CONSTRUCTION, MODIFICATION, MAINTENANCE AND DECOMMISSIONING OF FILLING STATIONS
EI TP PETROLEUM ROAD TANKER : 2010 PETROLEUM ROAD TANKER DESIGN AND CONSTRUCTION

View more information
US$301.86
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.