• There are no items in your cart

EN 1279-5:2005+A2:2010

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Glass in building - Insulating glass units - Part 5: Evaluation of conformity
Superseded date

07-20-2019

Published date

05-05-2010

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Evaluation of conformity
6 Marking and/or labelling
Annex A (normative) Rules for the use of 'other party
        ITT results'
Annex B (informative) Use of IGUs when subjected to UV
        and/or in SSG
Annex C (informative) Installation of the insulating
        glass units
Annex D (informative) Provisions for voluntary involvement
        of third party(ies)
Annex ZA (informative) Clauses of this European Standard
         addressing the provisions of EU Construction
         Products Directive
Bibliography

This European Standard specifies requirements, the evaluation of conformity and the factory production control of insulating glass units for use in buildings.NOTE 1For glass products with electrical wiring or connections for e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.The main intended uses of the insulating glass units are installations in windows, doors, curtain walling, roofs and partitions where there exists protection against direct ultraviolet radiation at the edges.NOTE 2In cases where there is no protection against direct ultra-violet radiation at the edges, such as structural sealant glazing systems, additional European technical specifications should be followed (e.g. !EN 15434", !EN 13022-1").NOTE 3Units for which the intended use is only ‘artistic’ and therefore no essential requirement is required, are not subject to CE marking and are not part of this European Standard.

Committee
CEN/TC 129
DevelopmentNote
2005 Edition Re-issued in May 2010 & incorporates AMD 2 2010. (05/2010)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

PREN 13830 : DRAFT 2013 CURTAIN WALLING - PRODUCT STANDARD
PREN 15254-4 : DRAFT 2016 EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS
DIN EN 15254-4:2013-10 EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS
17/30356436 DC : 0 BS EN 16612 - GLASS IN BUILDING - DETERMINATION OF THE LATERAL LOAD RESISTANCE OF GLASS PANES BY CALCULATION
DIN EN 13022-2:2014-08 GLASS IN BUILDING - STRUCTURAL SEALANT GLAZING - PART 2: ASSEMBLY RULES
UNE-EN 13022-2:2015 Glass in building - Structural sealant glazing - Part 2: Assembly rules
DIN EN 13830:2015-07 CURTAIN WALLING - PRODUCT STANDARD
EN 13022-2:2014 Glass in building - Structural sealant glazing - Part 2: Assembly rules
13/30281348 DC : 0 BS EN 13830 - CURTAIN WALLING - PRODUCT STANDARD
BS EN 16361 : 2013 POWER OPERATED PEDESTRIAN DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PEDESTRIAN DOORSETS, OTHER THAN SWING TYPE, INITIALLY DESIGNED FOR INSTALLATION WITH POWER OPERATION
PREN 16612 : DRAFT 2017 GLASS IN BUILDING - DETERMINATION OF THE LATERAL LOAD RESISTANCE OF GLASS PANES BY CALCULATION
I.S. EN 16361:2013 POWER OPERATED PEDESTRIAN DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PEDESTRIAN DOORSETS, OTHER THAN SWING TYPE, INITIALLY DESIGNED FOR INSTALLATION WITH POWER OPERATION
I.S. EN 13830:2015 CURTAIN WALLING - PRODUCT STANDARD
I.S. EN 14351-1:2006 WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND/OR SMOKE LEAKAGE CHARACTERISTICS
I.S. EN 13022-2:2014 GLASS IN BUILDING - STRUCTURAL SEALANT GLAZING - PART 2: ASSEMBLY RULES
I.S. EN 14600:2005 DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION
16/30347433 DC : 0 BS EN 15254-4 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS
12/30266506 DC : 0 BS EN 50583 - PHOTOVOLTAICS IN BUILDINGS
BS EN 14600:2005 Doorsets and openable windows with fire resisting and/ or smoke control characteristics. Requirements and classification
UNE-EN 13830:2016 Curtain walling - Product standard
EN 13830:2015 Curtain walling - Product standard
UNI EN 14600 : 2006 DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION
UNI EN 13022-2 : 2014 GLASS IN BUILDING - STRUCTURAL SEALANT GLAZING - PART 2: ASSEMBLY RULES
PREN 50583 : DRAFT 2012 PHOTOVOLTAICS IN BUILDINGS
BS EN 14351-1 : 2006 WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS
BS EN 13830:2015 Curtain walling. Product standard
EN 14351-1:2006+A2:2016 Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets
EN 14600:2005 Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification
EN 16361:2013+A1:2016 Power operated pedestrian doors - Product standard, performance characteristics - Pedestrian doorsets, other than swing type, initially designed for installation with power operation
DIN EN 15254-4 E : 2013 EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS
08/30172148 DC : DRAFT MAY 2008 BS ISO 28278-1 - GLASS IN BUILDING - GLASS PRODUCTS FOR STRUCTURAL SEALANT GLAZING - PART 1: SUPPORTED AND UNSUPPORTED MONOLITHIC AND MULTIPLE GLAZING
EN 15254-4:2008+A1:2011 Extended application of results from fire resistance tests - Non-loadbearing walls - Part 4: Glazed constructions
UNI EN 15254-4 : 2011 EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS
UNE-EN 15254-4:2009 Extended application of results from fire resistance tests - Non-loadbearing walls - Part 4: Glazed constructions
BS EN 15254-4 : 2008 EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS
I.S. EN 15254-4:2008 EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS
BS EN 13022-2:2014 Glass in building. Structural sealant glazing Assembly rules
DIN EN 14600:2006-03 DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION
UNE-EN 16361:2014 Power operated pedestrian doors - Product standard, performance characteristics - Pedestrian doorsets, other than swing type, initially designed for installation with power operation without resistance to fire and smoke leakage characteristics
UNE-EN 14351-1:2006 Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics

93/68/EEC : 1993 AMD 2 1998 COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC
EN 13022-1:2014 Glass in building - Structural sealant glazing - Part 1: Glass products for structural sealant glazing systems for supported and unsupported monolithic and multiple glazing
EN 12337-1:2000 Glass in building - Chemically strengthened soda lime silicate glass - Part 1: Definition and description
EN 13024-1:2011 Glass in building - Thermally toughened borosilicate safety glass - Part 1: Definition and description
EN 673:2011 Glass in building - Determination of thermal transmittance (U value) - Calculation method
EN 1748-2-1:2004 Glass in building - Special basic products - Glass ceramics - Part 2-1 Definitions and general physical and mechanical properties
EN 12758:2011 Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties
EN 410:2011 Glass in building - Determination of luminous and solar characteristics of glazing
EN 12898:2001 Glass in building - Determination of the emissivity
EN 1279-1:2004/AC:2006 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 1: GENERALITIES, DIMENSIONAL TOLERANCES AND RULES FOR THE SYSTEM DESCRIPTION
89/106/EEC : 1988 COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS
EN 15434:2006+A1:2010 Glass in building - Product standard for structural and/or ultra-violet resistant sealant (for use with structural sealant glazing and/or insulating glass units with exposed seals)
EN 1863-1:2011 Glass in building - Heat strengthened soda lime silicate glass - Part 1: Definition and description
EN 13501-5:2016 Fire classification of construction products and building elements - Part 5: Classification using data from external fire exposure to roofs tests
EN 14178-1:2004 Glass in building - Basic alkaline earth silicate glass products - Part 1: Float glass
EN 13541:2012 Glass in building - Security glazing - Testing and classification of resistance against explosion pressure
EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
EN 1279-6:2002 Glass in building - Insulating glass units - Part 6: Factory production control and periodic tests
EN 1279-3:2002 Glass in building - Insulating glass units - Part 3: Long term test method and requirements for gas leakage rate and for gas concentration tolerances
EN 12150-1:2015 Glass in building - Thermally toughened soda lime silicate safety glass - Part 1: Definition and description
EN 1279-4:2002 Glass in building - Insulating glass units - Part 4: Methods of test for the physical attributes of edge seals
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
EN 674:2011 Glass in building - Determination of thermal transmittance (U value) - Guarded hot plate method
EN 1063:1999 Glass in building - Security glazing - Testing and classification of resistance against bullet attack
EN 1748-1-1:2004 Glass in building - Special basic products -Borosilicate glasses - Part 1-1: Definition and general physical and mechanical properties
EN 357:2004 Glass in building - Fire resistant glazed elements with transparent or translucent glass products - Classification of fire resistance
ISO 12543-1:2011 Glass in building Laminated glass and laminated safety glass Part 1: Definitions and description of component parts
EN 675:2011 Glass in building - Determination of thermal transmittance (U value) - Heat flow meter method
EN 1279-2:2002 Glass in building - Insulating glass units - Part 2: Long term test method and requirements for moisture penetration
ISO 9001:2015 Quality management systems — Requirements
EN 572-1:2012+A1:2016 Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties
EN 356:1999 Glass in building - Security glazing - Testing and classification of resistance against manual attack
EN ISO 12543-1:2011 Glass in building - Laminated glass and laminated safety glass - Part 1: Definitions and description of component parts (ISO 12543-1:2011)
EN 12600:2002 Glass in building - Pendulum test - Impact test method and classification for flat glass

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.