• There are no items in your cart

EN 303-2:2017

Current
Current

The latest, up-to-date edition.

Heating boilers - Part 2: Heating boilers with forced draught burners - Special requirements for boilers with atomizing oil burners
Published date

08-16-2017

European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Performance requirements
5 Material performance
Annex A (normative) - Assembly criteria
Annex B (informative) - Example of test evaluation
        for a 3-months duration test
Annex ZA (informative) - Relationship between this
         European Standard and the ecodesign requirements
         of Commission Regulation (EU) No [813/2013] aimed
         to be covered
Bibliography

This European Standard is applicable to boilers used for central heating in accordance with prEN 303 1:2016 up to a nominal heat output of 1 000 kW and EN 303 4 up to a nominal heat output of 70 kW with forced draught burners in accordance with EN 267 that are designed for operating with liquid fuels.The performance requirements of this standard apply to type testing to heating boilers (standard, low temperature and condensing boilers) which are tested on a test rig in accordance with the test code given in EN 304. This standard applies also to room sealed boilers as defined in EN 15035 regarding efficiency and emissions.This standard can also be used as the basis for evaluation of boiler-/burner units.

DevelopmentNote
Supersedes PREN 303-2 and EN 15034. (08/2017)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current
Supersedes

PD CEN/TR 15316-6-4:2017 Energy performance of buildings. Method for calculation of system energy requirements and system efficiencies Explanation and justification of EN 15316-4-1, Module M3-8-1, M8-8-1
BS ISO 13675:2013 Heating systems in buildings. Method and design for calculation of the system energy performance. Combustion systems (boilers)
DIN EN 15456 E : 2008 HEATING BOILERS - ELECTRICAL POWER CONSUMPTION FOR HEAT GENERATORS - SYSTEM BOUNDARIES - MEASUREMENTS
EN 15316-4-1:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 4-1: Space heating and DHW generation systems, combustion systems (boilers, biomass), Module M3-8-1, M8-8-1
PREN 15316-4-1 : DRAFT 2014 HEATING SYSTEMS AND WATER BASED COOLING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-1: SPACE HEATING AND DHW GENERATION SYSTEMS, COMBUSTION SYSTEMS (BOILERS, BIOMASS)
EN 304:2017 Heating boilers - Test code for heating boilers for atomizing oil burners
17/30349925 DC : 0 BS EN 14825 - AIR CONDITIONERS, LIQUID CHILLING PACKAGES AND HEAT PUMPS, WITH ELECTRICALLY DRIVEN COMPRESSORS, FOR SPACE HEATING AND COOLING - TESTING AND RATING AT PART LOAD CONDITIONS AND CALCULATION OF SEASONAL PERFORMANCE
BS EN 304:2017 Heating boilers. Test code for heating boilers for atomizing oil burners
DIN EN 15034 E : 2007 EATING BOILERS - CONDENSING HEATING BOILERS FOR FUEL OIL
BS EN 303-3:1999 Heating boilers Gas-fired central heating boilers. Assembly comprising a boiler body and a forced draught burner
DIN EN 15034:2007-01 EATING BOILERS - CONDENSING HEATING BOILERS FOR FUEL OIL
14/30311499 DC : 0 BS EN 15316-4-1 - HEATING SYSTEMS AND WATER BASED COOLING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-1: SPACE HEATING AND DHW GENERATION SYSTEMS, COMBUSTION SYSTEMS (BOILERS, BIOMASS)
ISO 13675:2013 Heating systems in buildings Method and design for calculation of the system energy performance Combustion systems (boilers)
04/30122801 DC : DRAFT SEP 2004 EN 15034 - HEATING BOILERS - CONDENSING HEATING BOILERS FOR FUEL OIL
BS EN 303-6:2000 Heating boilers. Heating boilers with forced draught burners Specific requirements for the domestic hot water operation of combination boilers with atomizing oil burners of nominal heat input not exceeding 70 kW
I.S. EN 303-1:2017 HEATING BOILERS - PART 1: HEATING BOILERS WITH FORCED DRAUGHT BURNERS - TERMINOLOGY, GENERAL REQUIREMENTS, TESTING AND MARKING
I.S. EN 14394:2006 HEATING BOILERS - HEATING BOILERS WITH FORCED DRAUGHT BURNERS - NOMINAL HEAT OUTPUT NOT EXCEEDING 10 MW AND MAXIMUM OPERATING TEMPERATURE OF 110 DEGREE C
17/30348438 DC : 0 BS EN 303-6 - HEATING BOILERS - PART 6: HEATING BOILERS WITH FORCED DRAUGHT BURNERS - SPECIFIC REQUIREMENTS FOR THE DOMESTIC HOT WATER OPERATION AND ENERGY PERFORMANCE OF WATER HEATERS AND COMBINATION BOILERS WITH ATOMIZING OIL BURNERS OF NOMINAL HEAT INPUT NOT EXCEEDING 70 KW
04/30122798 DC : DRAFT SEP 2004 EN 15035 - HEATING BOILERS - ROOM SEALED OPERATIONS FOR BOILERS FOR FUEL OIL
I.S. EN 15034:2006 HEATING BOILERS - CONDENSING HEATING BOILERS FOR FUEL OIL
PREN 303-6 : DRAFT 2017 HEATING BOILERS - PART 6: HEATING BOILERS WITH FORCED DRAUGHT BURNERS - SPECIFIC REQUIREMENTS FOR THE DOMESTIC HOT WATER OPERATION AND ENERGY PERFORMANCE OF WATER HEATERS AND COMBINATION BOILERS WITH ATOMIZING OIL BURNERS OF NOMINAL HEAT INPUT NOT EXCEEDING 70 KW
09/30202307 DC : 0 BS EN 12514-1 - PARTS FOR SUPPLY SYSTEMS FOR CONSUMING UNITS WITH LIQUID FUELS - PART 1: SAFETY REQUIREMENTS AND TESTS - TERMINOLOGY, GENERAL REQUIREMENTS
I.S. EN 304:2017 HEATING BOILERS - TEST CODE FOR HEATING BOILERS FOR ATOMIZING OIL BURNERS
EN 303-3:1998/AC:2006 HEATING BOILERS - PART 3: GAS-FIRED CENTRAL HEATING BOILERS ASSEMBLY COMPRISING A BOILER BODY AND A FORCED DRAUGHT BURNER
DIN EN 14394 E : 2008 HEATING BOILERS - HEATING BOILERS WITH FORCED DRAUGHT BURNERS - NOMINAL HEAT OUTPUT NOT EXCEEDING 10 MW AND MAXIMUM OPERATING TEMPERATURE OF 110 DEGREE C
DIN EN 14394:2008-12 HEATING BOILERS - HEATING BOILERS WITH FORCED DRAUGHT BURNERS - NOMINAL HEAT OUTPUT NOT EXCEEDING 10 MW AND MAXIMUM OPERATING TEMPERATURE OF 110 DEGREE C
BS EN 15034:2006 Heating boilers. Condensing heating boilers for fuel oil
UNI EN 15034 : 2007 HEATING BOILERS - CONDENSING HEATING BOILERS FOR FUEL OIL
UNI EN 14394 : 2008 HEATING BOILERS - HEATING BOILERS WITH FORCED DRAUGHT BURNERS - NOMINAL HEAT OUTPUT NOT EXCEEDING 10 MW AND MAXIMUM OPERATING TEMPERATURE OF 110 DEGREES C
DIN EN 303-1:2016-07 (Draft) HEATING BOILERS - PART 1: HEATING BOILERS WITH FORCED DRAUGHT BURNERS - TERMINOLOGY, GENERAL REQUIREMENTS, TESTING AND MARKING
CEN/TR 15316-6-4:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 6-4: Explanation and justification of EN 15316-4-1, Module M3-8-1, M8-8-1
I.S. EN 15456:2008 HEATING BOILERS - ELECTRICAL POWER CONSUMPTION FOR HEAT GENERATORS - SYSTEM BOUNDARIES - MEASUREMENTS
BS EN 14394 : 2005 HEATING BOILERS - HEATING BOILERS WITH FORCED DRAUGHT BURNERS - NOMINAL HEAT OUTPUT NOT EXCEEDING 10 MW AND MAXIMUM OPERATING TEMPERATURE OF 110 DEGREE C
BS EN 15035:2006 Heating boilers. Special requirements for oil fired room sealed units up to 70 kW
BS EN 303-4:1999 Heating boilers. Heating boilers with forced draught burners Heating boilers with forced draught burners. Special requirements for boilers with forced draught oil burners with outputs up to 70 kW and a maximum operating pressure of 3 bar. Terminology, special requirements, testing and marking
EN 15456:2008 Heating boilers - Electrical power consumption for heat generators - System boundaries - Measurements
EN 14394:2005+A1:2008 Heating boilers - Heating boilers with forced draught burners - Nominal heat output not exceeding 10 MW and maximum operating temperature of 110 °C
EN 15035:2006 Heating boilers - Special requirements for oil fired room sealed units up to 70 kW
EN 303-6:2000 Heating boilers - Part 6: Heating boilers with forced draught burners - Specific requirements for the domestic hot water operation of combination boilers with atomizing oil burners of nominal heat input not exceeding 70 kW
EN 303-1:2017 Heating boilers - Part 1: Heating boilers with forced draught burners - Terminology, general requirements, testing and marking
EN 303-4:1999 Heating boilers - Part 4: Heating boilers with forced draught burners - Special requirements for boilers with forced draught oil burners with outputs up to 70 kW and a maximum operating pressure of 3 bar - Terminology, special requirements, testing and marking
DIN EN 15316-4-1:2008-09 ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-1: SPACE HEATING AND DHW GENERATION SYSTEMS, COMBUSTION SYSTEMS (BOILERS, BIOMASS), MODULE M3-8-1, M8-8-1
BS EN 15456:2008 Heating boilers. Electrical power consumption for heat generators. System boundaries. Measurements
S.R. CEN/TR 15316-6-4:2017 ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 6-4: EXPLANATION AND JUSTIFICATION OF EN 15316-4-1, MODULE M3-8-1, M8-8-1
PREN 14825 : DRAFT 2017 AIR CONDITIONERS, LIQUID CHILLING PACKAGES AND HEAT PUMPS, WITH ELECTRICALLY DRIVEN COMPRESSORS, FOR SPACE HEATING AND COOLING - TESTING AND RATING AT PART LOAD CONDITIONS AND CALCULATION OF SEASONAL PERFORMANCE
12/30239784 DC : 0 BS ISO 13675 - HEATING AND COOLING SYSTEMS IN BUILDINGS - METHOD AND DESIGN FOR CALCULATION OF THE SYSTEM ENERGY PERFORMANCE - COMBUSTION SYSTEMS (BOILERS)
DIN EN 15456:2008-06 Heating boilers - Electrical power consumption for heat generators - System boundaries - Measurements
UNI EN 15456 : 2008 HEATING BOILERS - ELECTRICAL POWER CONSUMPTION FOR HEAT GENERATORS - SYSTEM BOUNDARIES - MEASUREMENTS
I.S. EN 15316-4-1:2017 ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-1: SPACE HEATING AND DHW GENERATION SYSTEMS, COMBUSTION SYSTEMS (BOILERS, BIOMASS), MODULE M3-8-1, M8-8-1
DIN EN 15035 E : 2007 HEATING BOILERS - SPECIAL REQUIREMENTS FOR OIL FIRED ROOM SEALED UNITS UP TO 70 KW
BS EN 303-1:2017 Heating boilers Heating boilers with forced draught burners. Terminology, general requirements, testing and marking
DIN EN 15035:2007-05 Heating boilers - Special requirements for oil fired room sealed units up to 70 kW

EN 15502-1:2012+A1:2015 Gas-fired heating boilers - Part 1: General requirements and tests
EN 303-6:2000 Heating boilers - Part 6: Heating boilers with forced draught burners - Specific requirements for the domestic hot water operation of combination boilers with atomizing oil burners of nominal heat input not exceeding 70 kW
EN 304:2017 Heating boilers - Test code for heating boilers for atomizing oil burners
EN 15456:2008 Heating boilers - Electrical power consumption for heat generators - System boundaries - Measurements
EN 303-1:2017 Heating boilers - Part 1: Heating boilers with forced draught burners - Terminology, general requirements, testing and marking
EN 267:2009+A1:2011 Automatic forced draught burners for liquid fuels
EN 303-4:1999 Heating boilers - Part 4: Heating boilers with forced draught burners - Special requirements for boilers with forced draught oil burners with outputs up to 70 kW and a maximum operating pressure of 3 bar - Terminology, special requirements, testing and marking
EN 15035:2006 Heating boilers - Special requirements for oil fired room sealed units up to 70 kW
EN 15316-4-1:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 4-1: Space heating and DHW generation systems, combustion systems (boilers, biomass), Module M3-8-1, M8-8-1
EN 15036-1:2006 Heating boilers - Test regulations for airborne noise emissions from heat generators - Part 1: Airborne noise emissions from heat generators

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.