EN 50265-2-2:1998

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-2: Procedures - Diffusion flame

Superseded date

11-01-2004

Published date

07-06-1998

1 Scope
2 Normative references
3 Definitions
4 Test apparatus
    4.1 General
    4.2 Ignition source
5 Procedure
    5.1 Sample
    5.2 Conditioning
    5.3 Positioning of test piece
    5.4 Flame application
6 Evaluation of test results
Annex A (informative) Recommended performance requirements
Annex A (informative) Bibliography

This standard specifies a method of testing a small insulated wire under fire conditions when the method specified in IEC Publication 332-1 is not suitable because some small conductors may melt during the application of the flame - The range of application recommended is for solid copper conductors from 0.4 mm to 0.8 mm diameter and for stranded conductors from 0.1 mm2 to 0.5 mm 2 cross-section - This standard includes the requirement for compliance - Note: The use of insulated wire which complies with this standard is not sufficient to prevent flame propagation under all conditions of installation - When the risk of propagation is high, such as with long vertical runs of bunches of wires, it cannot be assumed that, because a sample complies with this standard, the bunch will behave in a similar manner

Committee
CLC/TC 20
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy
Supersedes

HD 21.1 : 200S4 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - GENERAL REQUIREMENTS
VDE 0482-265-2-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PART 2-1: PROCEDURES - 1 KW PRE-MIXED FLAME
I.S. EN 45510-2-8:2004 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES
CEI UNI EN 45510-2-8 : 2006 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES
HD 637 S1:1999/corrigendum:2005 POWER INSTALLATIONS EXCEEDING 1 KV A.C.
EN 45510-2-8 : 2004 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES
HD 22-1 : 200S4 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOSETTING INSULATION - GENERAL REQUIREMENTS
99/201485 DC : DRAFT MAR 99 EN 50288 SERIES - MULIT-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 1: GENERIC SPECIFICATION; PART 2-1: SS FOR SCREENED CABLES CHARACTERISED UP TO 100 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLE: PART 2-2: SS FOR SCREENED CABLES CHARACTERISED UP TO 100 MHZ - WORK AREA & PATCH CORD CABLES; PART 3-1: SS FOR UNSCREENED CABLES CONT:
BS EN 45510-2-8:2004 Guide for procurement of power station equipment Electrical equipment - Power cables
I.S. HD 22-1:2002 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 1: GENERAL REQUIREMENTS
DIN EN 50265-2-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PART 2-1: PROCEDURES - 1 KW PRE-MIXED FLAME
04/30117156 DC : DRAFT JUL 2004 EN 50441-1 - UN-SCREENED CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: GRADE 1
EN 45510-2-8:2004 Guide for procurement of power station equipment - Part 2-8: Electrical equipment - Power cables
I.S. HD 21-2:1998 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2: TEST METHODS
UNI CEI EN 45510-2-8 : 2011 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES
I.S. HD 21-1:2002 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 1: GENERAL REQUIREMENTS
I.S. HD 637:1999 POWER INSTALLATIONS EXCEEDING 1 KV A.C.
HD 22.2 S3:1997/A1:2002 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOSETTING INSULATION - TEST METHODS
HD 21-2 : S3 AMD 1 2002 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - TEST METHODS

EN 60695-4:2012 FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012)
EN 50265-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 1: Apparatus

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.