EN 54-10:2002/A1:2005
Current
The latest, up-to-date edition.
FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 10: FLAME DETECTORS - POINT DETECTORS
11-23-2005
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Tests
6 Marking
Annex A (normative) - Annex A Apparatus for response point
determination
Annex B (informative) - Example of a methane burner
Annex C (normative) - Test fires
Annex D (normative) - Apparatus for dazzling test
Annex E (normative) - Apparatus for impact test
Annex ZA (informative) - Clauses addressing the provisions
of the EU Construction Products Directive 89/106/EEC
Bibliography
Covers requirements, test methods and performance criteria for point-type, resettable flame detectors that operate using radiation from a flame for use in fire detection systems installed in buildings.
Committee |
CEN/TC 72
|
DocumentType |
Test Method
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
DIN EN 54-10:2002-05 | Identical |
SANS 50054-10 : 1ED 2010(R2016) | Identical |
NBN EN 54-10 : 2002 AMD 1 2006 | Identical |
SN EN 54-10 : 2002 AMD 1 2006 | Identical |
DIN EN 54-10:2012-01 (Draft) | Identical |
DIN EN 54-10 E : 2002 | Identical |
PN EN 54-10 : 2005 AMD 1 2006 | Identical |
UNI EN 54-10 : 2006 | Identical |
NF EN 54-10 : 2002 AMD 1 2006 | Identical |
BS EN 54-10:2002 | Identical |
DIN EN 54-10/A1:2006-03 | Identical |
UNE-EN 54-10:2002 | Identical |
NEN EN 54-10 : 2002 AMD 1 2005 | Identical |
NS EN 54-10 : 2002 AMD 1 2006 | Identical |
I.S. EN 54-10:2002 | Identical |
04/30095958 DC : DRAFT DEC 2004 | ISO 19292 - SHIPS AND MARINE TECHNOLOGY - POINT-TYPE RESETTABLE FLAME DETECTORS FOR SHIPS |
DD CEN/TS 54-14:2004 | Fire detection and fire alarm systems Guidelines for planning, design, installation, commissioning, use and maintenance |
I.S. EN CLC TS 50398:2003 | ALARM SYSTEMS - COMBINED AND INTEGRATED ALARM SYSTEMS - GENERAL REQUIREMENTS |
DD CEN/TS 14816:2008 | Fixed firefighting systems. Water spray systems. Design and installation |
05/30117311 DC : 0 | EN 54-25 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS AND SYSTEM REQUIREMENTS |
04/30119106 DC : DRAFT AUG 2004 | EN 14972 - FIXED FIREFIGHTING SYSTEMS - WATERMIST SYSTEMS - DESIGN AND INSTALLATION |
92/39221 DC : DRAFT APRIL 1992 | BS 5839:PART 7 - SPECIFICATION FOR FIRE DETECTION AND ALARM SYSTEMS FOR BUILDINGS - PART 7 - FLAME DETECTORS FOR SPECIAL RISKS |
CEN/TS 54-14:2004 | Fire detection and fire alarm systems - Part 14: Guidelines for planning, design, installation, commissioning, use and maintenance |
11/30249544 DC : 0 | BS EN 54-14 - FIRE DETECTION AND FIRE ALARM SYSTEMS - GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE |
00/104442 DC : DRAFT JUNE 2000 | PREN 13916 - FIRE RESISTING DOORSETS - REQUIREMENTS AND CLASSIFICATION |
06/30117299 DC : 0 | BS EN 54-15 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 15: POINT DETECTORS USING A COMBINATION OF DETECTED FIRE PHENOMENA |
I.S. CEN TS 54-14:2004 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 14: GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE |
UNI CEN/TS 14816 : 2009 | FIXED FIREFIGHTING SYSTEMS - WATER SPRAY SYSTEMS - DESIGN, INSTALLATION AND MAINTENANCE |
03/317852 DC : 0 | BS EN 14816 - FIXED FIREFIGHTING SYSTEMS - WATER SPRAY SYSTEMS - DESIGN AND INSTALLATION |
S.R. CEN/TS 14816:2008 | FIXED FIREFIGHTING SYSTEMS - WATER SPRAY SYSTEMS - DESIGN, INSTALLATION AND MAINTENANCE |
CEN/TS 14816:2008 | Fixed firefighting systems - Water spray systems - Design, installation and maintenance |
ISO 209-1:1989 | Wrought aluminium and aluminium alloys Chemical composition and forms of products Part 1: Chemical composition |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60064:1993+AMD1:2000+AMD2:2002+AMD3:2005 CSV | Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
ISO 9001:2015 | Quality management systems — Requirements |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
IEC 60068-2-56:1988 | Environmental testing - Part 2: Tests. Test Cb: Damp heat, steady state, primarily for equipment |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.