• There are no items in your cart

EN 60317-46:2014

Current
Current

The latest, up-to-date edition.

Specifications for particular types of winding wires - Part 46: Aromatic polyimide enamelled round copper wire, class 240
Published date

02-14-2014

FOREWORD
INTRODUCTION
1 Scope
2 Normative reference
3 Terms, definitions, general notes and appearance
4 Dimensions
5 Electrical resistance
6 Elongation
7 Springiness
8 Flexibility and adherence
9 Heat shock
10 Cut-through
11 Resistance to abrasion (nominal conductor diameters from
   0,250 mm up to and including 2,500 mm)
12 Resistance to solvents
13 Breakdown voltage
14 Continuity of insulation
15 Temperature index
16 Resistance to refrigerants
17 Solderability
18 Heat or solvent bonding
19 Dielectric dissipation factor
20 Resistance to transformer oil
21 Loss of mass
23 Pin hole test
30 Packaging
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

IEC 60317-46:2013 specifies the requirements of enamelled round copper winding wire of class 240 with a sole coating of aromatic polyimide resin. The range of nominal conductor diameters covered by this standard is: - grade 1: 0,020 mm up to and including 2,000 mm; - grade 2: 0,020 mm up to and including 5,000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013. This second edition cancels and replaces the first edition published in 1997. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - deletion of the 'in some countries' statement in the scope; - new subclause containing general notes on winding wire, formerly a part of the scope; - new subclause containing requirements for appearance; - revision to the notes in Clause 19, Dielectric dissipation factor; - new Clause 23, Pin-hole test. Keywords: requirements of enamelled round copper winding wire, class 240, sole coating of aromatic polyimide resin

Committee
CLC/TC 55
DevelopmentNote
To be read in conjunction with EN 60317-0-1. (02/2014)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

I.S. EN 61858:2008 ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS
CEI EN 60317-50 : 2013 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 50: GLASS-FIBRE WOUND SILICONE RESIN OR VARNISH IMPREGNATED, BARE OR ENAMELLED ROUND COPPER WIRE, TEMPERATURE INDEX 200
EN IEC 60079-7:2015/A1:2018 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017)
BS EN 60079-7 : 2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015)
BS EN 61858-1:2014 Electrical insulation systems. Thermal evaluation of modifications to an established electrical insulation system (EIS) Wire-wound winding EIS
BS EN 61858:2008 Electrical insulation systems. Thermal evaluation of modifications to an established wire-wound EIS
I.S. EN 60317-50:2012 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 50: GLASS-FIBRE WOUND SILICONE RESIN OR VARNISH IMPREGNATED, BARE OR ENAMELLED ROUND COPPER WIRE, TEMPERATURE INDEX 200 (IEC 60317-50:2012 (EQV))
I.S. EN 61858-1:2014 ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 1: WIRE-WOUND WINDING EIS
UNE-EN 60317-50:2013 Specifications for particular types of winding wires - Part 50: Glass-fibre wound silicone resin or varnish impregnated, bare or enamelled round copper wire, temperature index 200
BS EN 60317-50:2012 Specifications for particular types of winding wires Glass-fibre wound silicone resin or varnish impregnated, bare or enamelled round copper wire, temperature index 200
I.S. EN 60079-7:2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
UNE-EN 60079-7:2016 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
EN 61858-1:2014 Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 1: Wire-wound winding EIS
EN 60317-50 : 2012 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 50: GLASS-FIBRE WOUND SILICONE RESIN OR VARNISH IMPREGNATED, BARE OR ENAMELLED ROUND COPPER WIRE, TEMPERATURE INDEX 200
EN 61858:2008 ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS

EN 60317-0-1:2014 Specifications for particular types of winding wires - Part 0-1: General requirements - Enamelled round copper wire
IEC 60317-0-1:2013 Specifications for particular types of winding wires - Part 0-1: General requirements - Enamelled round copper wire

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.