EN 60601-2-64:2015

Current
Current

The latest, up-to-date edition.

Medical electrical equipment - Part 2-64: Particular requirements for the basic safety and essential performance of light ion beam medical electrical equipment
Published date

05-29-2015

FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing of ME
        EQUIPMENT
201.6 Classification of ME EQUIPMENT and
        ME SYSTEMS
201.7 ME EQUIPMENT identification, marking
        and documents
201.8 Protection against electrical HAZARDS from
        ME EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS
        of ME EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive radiation
        HAZARDS
201.11 Protection against excessive temperatures and other
        HAZARDS
201.12 Accuracy of controls and instruments and protection
        against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions
        for ME EQUIPMENT
201.14 PROGRAMMABLE ELECTRICAL MEDICAL
        SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 ELECTROMAGNETIC COMPATIBILITY of ME
        EQUIPMENT and ME SYSTEMS
201.101 ELECTRONIC IMAGING DEVICES (EID)
206 Usability
Annexes
Annex B (informative) - Sequence of testing
Annex I (informative) - ME SYSTEMS aspects
Bibliography
Index of defined terms used in this particular standard
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications
Annex ZZ (informative) - Coverage of Essential
         Requirements of EU Directives

IEC 60601-2-64:2014 applies to the basic safety and essential performance of Light Ion Beam Medical Electrical equipment, hereafter referred to as ME equipment, used for treatment of patients. This particular standard, with the inclusion of type tests and site tests, applies respectively to the manufacture and some installation aspects of ME equipment intended for radiotherapy in human medical practice, including those in which the selection and display of operating parameters can be controlled automatically by programmable electronic subsystems, that, in normal use, deliver a radiation beam of light ions having energy per nucleon in the range 10 MeV/n to 500 MeV/n.Key words: nuclear medicine, radiation dosimetry.

Committee
CLC/TC 62
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

I.S. EN IEC 62667:2018 MEDICAL ELECTRICAL EQUIPMENT - MEDICAL LIGHT ION BEAM EQUIPMENT - PERFORMANCE CHARACTERISTICS
BS EN IEC 62667:2018 Medical electrical equipment. Medical light ion beam equipment. Performance characteristics
EN IEC 62667:2018 Medical electrical equipment - Medical light ion beam equipment - Performance characteristics

EN 61217:2012 Radiotherapy equipment - Coordinates, movements and scales
EN 60601-2-11:2015 Medical electrical equipment - Part 2-11: Particular requirements for the basic safety and essential performance of gamma beam therapy equipment
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
EN 60601-2-68:2015 Medical electrical equipment - Part 2-68: Particular requirements for the basic safety and essential performance of X-ray-based image-guided radiotherapy equipment for use with electron accelerators, light ion beam therapy equipment and radionuclide beam therapy equipment
ISO/IEC 14165-321:2009 Information technology Fibre Channel Part 321: Audio-Video (FC-AV)
IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
EN 60601-1-2:2015 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60601-2-1:2009+AMD1:2014 CSV Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV
IEC 61217:2011 Radiotherapy equipment - Coordinates, movements and scales
IEC 60601-2-11:2013 Medical electrical equipment - Part 2-11: Particular requirements for the basic safety and essential performance of gamma beam therapy equipment

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.