• There are no items in your cart

EN 61557-1:2007

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements

Superseded date

12-16-2021

Published date

03-23-2007

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
  4.1 Operating uncertainty (B), percentage operating
       uncertainty (B [%])
  4.2 Rated operating conditions
  4.3 Battery check facility
  4.4 Terminals
  4.5 Class of protection
  4.6 Class of pollution
  4.7 Overvoltage category
  4.8 Measuring category
  4.9 Electromagnetic compatibility
  4.10 Vibration test
5 Marking and operating instructions
  5.1 Marking
  5.2 Operating instructions
6 Tests
  6.1 Influence of position
  6.2 Influence of temperature
  6.3 Influence of the supply voltage
  6.4 Battery check facility
  6.5 Protection class
  6.6 Terminals
  6.7 Mechanical requirements
  6.8 Marking and operating instructions
Bibliography
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications

This part of IEC 61557 specifies the general requirements for measuring and monitoring equipment for testing the electrical safety in low voltage distribution systems with nominal voltages up to 1 000 V a.c. and 1 500 V d.c. When measuring equipment or measuring installations involve measurement tasks of various measuring equipment covered by this series of standards, then the part of this series of standards relevant to each of the measurement tasks is applicable. This second edition replaces and cancels the first edition published in 1997. It constitutes a technical revision. The following changes were made with respect to the previous edition: a) revision of the definitions; b) addition of influence quantities E9 and E10; c) the subclause on Electromagnetic compatibility was complemented; d) inclusion of performance monitoring devices in the introduction; e) addition of new requirements for operating instructions.

Committee
CLC/TC 85X
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

BS EN 61557-2:2007 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Insulation resistance
CEI EN 61557-3 : 2008 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 3: LOOP IMPEDANCE
BS EN 50533 : 2011 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
BS EN 62353:2014 Medical electrical equipment. Recurrent test and test after repair of medical electrical equipment
I.S. EN 61557-7:2007 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1 000 V A.C. AND 1 500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 7: PHASE SEQUENCE
I.S. EN 61557-16:2015 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 16: EQUIPMENT FOR TESTING THE EFFECTIVENESS OF THE PROTECTIVE MEASURES OF ELECTRICAL EQUIPMENT AND/OR MEDICAL ELECTRICAL EQUIPMENT
BS EN 61557-5:2007 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Resistance to earth
CEI EN 61557-14 : 2014 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 14: EQUIPMENT FOR TESTING THE SAFETY OF ELECTRICAL EQUIPMENT OF MACHINERY
I.S. EN 61557-10:2013 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 10: COMBINED MEASURING EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES (IEC 61557-10:2013 (EQV))
BS EN 61557-8:2015 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Insulation monitoring devices for IT systems
BS EN 61557-11:2009 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c.. Equipment for testing, measuring or monitoring of protective measures Effectiveness of residual current monitors (RCMs) type A and type B in TT, TN and IT systems
EN 61557-14:2013 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 14: Equipment for testing the safety of electrical equipment of machinery
EN 61557-3:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance
EN 61557-10:2013 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 10: Combined measuring equipment for testing, measuring or monitoring of protective measures
EN 61557-15:2014 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems
EN 61557-11:2009 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 11: Effectiveness of residual current monitors (RCMs) type A and type B in TT, TN and IT systems
EN 62353:2014 Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment
BS EN 61557-6:1998 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring ormonitoring of protective measures Residual current devices (RCD) in TT, TN and IT systems
BS EN 61557-7:2007 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Phase sequence
DIN EN 61557-4 : 2007 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 4: RESISTANCE OF EARTH CONNECTION AND EQUIPOTENTIAL BONDING
UNE-EN 61557-12:2010 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures -- Part 12: Performance measuring and monitoring devices (PMD)
CEI EN 61557-13 : 2012 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 13: HAND-HELD AND HAND-MANIPULATED CURRENT CLAMPS AND SENSORS FOR MEASUREMENT OF LEAKAGE CURRENTS IN ELECTRICAL DISTRIBUTION SYSTEMS
I.S. EN 61557-6:2007 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 6: EFFECTIVENESS OF RESIDUAL CURRENT DEVICES (RCD) IN TT, TN AND IT SYSTEMS
I.S. EN 61557-4:2007 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 4: RESISTANCE OF EARTH CONNECTION AND EQUIPOTENTIAL BONDING
I.S. EN 61557-2:2007 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 2: INSULATION RESISTANCE
I.S. EN 61557-5:2007 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 5: RESISTANCE TO EARTH
EN 61557-8:2015/AC:2016-06 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems
DIN EN 61557-7 : 2008 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 7: PHASE SEQUENCE
OVE/ONORM EN 61557-6 : 2008 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 6: EFFECTIVENESS OF RESIDUAL CURRENT DEVICES (RCD) IN TT, TN AND IT SYSTEMS
CEI EN 61557-11 : 2013 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 11: EFFECTIVENESS OF RESIDUAL CURRENT MONITORS (RCMS) TYPE A AND TYPE B IN TT, TN AND IT SYSTEMS
UNE-EN 61557-13:2012 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 13: Hand-held and hand-manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems
09/30214359 DC : 0 BS EN 50533 - RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
CEI EN 61557-4 : 2008 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 4: RESISTANCE OF EARTH CONNECTION AND EQUIPOTENTIAL BONDING
I.S. EN 62353:2014 MEDICAL ELECTRICAL EQUIPMENT - RECURRENT TEST AND TEST AFTER REPAIR OF MEDICAL ELECTRICAL EQUIPMENT
CEI EN 61557-7 : 2008 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 7: PHASE SEQUENCE
CEI EN 50533 : 2012 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
I.S. EN 61557-3:2007 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 3: LOOP IMPEDANCE
I.S. EN 61557-9:2015 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS
UNE-EN 61557-8:2016 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems
02/705050 DC : DRAFT APR 2002 PREN 14419 - DISTRICT HEATING PIPES - PREINSULATED BONDED PIPE SYSTEMS FOR DIRECTLY BURIED HOT WATER NETWORKS - SURVEILLANCE SYSTEMS
BS EN 61557-13:2011 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Hand-held and hand-manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems
BS EN 61557-3:2007 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Loop impedance
CEI EN 61557-5 : 2008 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 5: RESISTANCE TO EARTH
DIN EN 61557-2 : 2008 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 2: INSULATION RESISTANCE
I.S. EN 61557-12:2008 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 12: PERFORMANCE MEASURING AND MONITORING DEVICES (PMD)
CEI EN 61557-12 : 2013 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 12: PERFORMANCE MEASURING AND MONITORING DEVICES (PMD)
CEI EN 61557-2 : 2008 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 2: INSULATION RESISTANCE
I.S. EN 61557-8:2015 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 8: INSULATION MONITORING DEVICES FOR IT SYSTEMS
I.S. EN 61557-13:2011 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 13: HAND-HELD AND HAND-MANIPULATED CURRENT CLAMPS AND SENSORS FOR MEASUREMENT OF LEAKAGE CURRENTS IN ELECTRICAL DISTRIBUTION SYSTEMS (IEC 61557-13:2011 (EQV))
UNE-EN 61557-11:2010 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 11: Effectiveness of residual current monitors (RCMs) type A and type B in TT, TN and IT systems
EN 61557-13:2011 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 13: Hand-held and hand-manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems
BS EN 61557-4:2007 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Resistance of earth connection and equipotential bonding
UNE-EN 50533:2012 Railway applications - Three-phase train line voltage characteristics.
BS EN 61557-10:2013 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Combined measuring equipment for testing, measuring or monitoring of protective measures
BS EN 61557-12:2008 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Performance measuring and monitoring devices (PMD)
CEI EN 61557-8 : 2016 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 8: INSULATION MONITORING DEVICES FOR IT SYSTEMS
I.S. EN 61557-11:2009 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 11: EFFECTIVENESS OF RESIDUAL CURRENT MONITORS (RCMS) TYPE A AND TYPE B IN TT, TN AND IT SYSTEMS
BS EN 61557-16:2015 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment
CEI EN 61557-10 : 2014 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 10: COMBINED MEASURING EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES
PREN 50533 : DRAFT 2009 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
DIN EN 61557-3 : 2008 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 3: LOOP IMPEDANCE
BS EN 61557-14:2013 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Equipment for testing the safety of electrical equipment of machinery
I.S. EN 50533:2011 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
I.S. EN 61557-14:2013 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1 000 V A.C. AND 1 500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 14: EQUIPMENT FOR TESTING THE SAFETY OF ELECTRICAL EQUIPMENT OF MACHINERY (IEC 61557-14:2013 (EQV))
I.S. EN 61557-15:2014 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 15: FUNCTIONAL SAFETY REQUIREMENTS FOR INSULATION MONITORING DEVICES IN IT SYSTEMS AND EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS
CEI EN 61557-6 : 2008 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 6: EFFECTIVENESS OF RESIDUAL CURRENT DEVICES (RCD) IN TT, TN AND IT SYSTEMS
BS EN 61557-9:2015 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Equipment for insulation fault location in IT systems
BS EN 61557-15:2014 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems
EN 61557-7:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence
EN 61557-5:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 5: Resistance to earth
EN 61557-12:2008 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD)
EN 61557-9:2015/AC:2017-02 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS (IEC 61557-9:2014/COR2:2017)
EN 61557-2:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance
EN 61557-16:2015 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 16: Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment
EN 61557-4:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding
EN 50533 : 2011 AMD 1 2016 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
EN 61557-6:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems

EN 61557-10:2013 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 10: Combined measuring equipment for testing, measuring or monitoring of protective measures
IEC 60038:2009 IEC standard voltages
EN 61557-2:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance
IEC 61326-2-4:2012 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9
IEC 60050-601:1985 International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General
EN 61557-4:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding
IEC 61557-10:2013 Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 10: Combined measuring equipment for testing, measuring and monitoring of protective measures
HD 472 S1:1989/AC:2013 NOMINAL VOLTAGES FOR LOW-VOLTAGE PUBLIC ELECTRICITY SUPPLY SYSTEMS
IEC 61010-2-030:2017 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-030: Particular requirements for equipment having testing or measuring circuits
IEC 60364-1:2005 Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions
EN 61557-3:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance
IEC 61557-2:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance
IEC 60364-6:2016 Low voltage electrical installations - Part 6: Verification
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 61326-2-2:2012 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low-voltage distribution systems
IEC 60359:2001 Electrical and electronic measurement equipment - Expression of performance
IEC 60050-826:2004 International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations
IEC 61557-4:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding
IEC 61557-9:2014 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems
EN 61557-5:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 5: Resistance to earth
EN 61557-6:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems
IEC 61557-7:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence
EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 61557-8:2015/AC:2016-06 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems
EN 61557-7:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence
IEC 61557-8:2014 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems
IEC 61557-6:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems
IEC 61010-1:2010+AMD1:2016 CSV Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
EN 61326-2-4:2013 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
EN 61557-9:2015/AC:2017-02 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS (IEC 61557-9:2014/COR2:2017)
IEC 60050-300:2001 International Electrotechnical Vocabulary (IEV) - Part 300: Electrical and electronic measurements and measuring instruments - Part 311: General terms relating to measurements - Part 312: General terms relating to electrical measurements - Part 313: Types of electrical measuring instruments - Part 314: Specific terms according to the type of instrument
EN 61326-2-2:2013 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61557-3:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.