Hydroelectric power plant automation - Guide for computer-based control
Withdrawn date

07-01-2007

Published date

07-23-2004

INTRODUCTION
1 Overview
   1.1 Scope
   1.2 Purpose
2 Normative references
3 Terms and definitions
4 Functional capabilities
   4.1 General
   4.2 Control capabilities
   4.3 Data acquisition capabilities
   4.4 Alarm processing and diagnostics
   4.5 Report generation
   4.6 Maintenance management interface
   4.7 Data archival and retrieval
   4.8 Operation scheduling and forecasting
   4.9 Data access
   4.10 Operator simulation training
   4.11 Typical control parameters
5 System architecture, communications, and databases
   5.1 General
   5.2 System classification
   5.3 System architecture characteristics
   5.4 Control data networks
   5.5 Data bases and software configuration
6 User and plant interfaces
   6.1 User interfaces
   6.2 Plant interfaces
7 System performance
   7.1 General
   7.2 Hardware
   7.3 Communications
   7.4 Measuring performance
8 System backup capabilities
   8.1 General
   8.2 Design principles
   8.3 Basic functions
   8.4 Design of equipment for backup control
   8.5 Alarm handling
   8.6 Protective f unction
9 Site integration and support systems
   9.1 Interface to existing equipment
   9.2 Environmental conditions
   9.3 Power source
   9.4 Supervision of existing contact status points
   9.5 Supervision of existing transducers
   9.6 Supervision of existing control output points
   9.7 Grounding
   9.8 Static control
10 Recommended test and acceptance criteria
   10.1 Specific test requirements
   10.2 Quality assurance
   10.3 Acceptance
11 System management
   11.1 Maintenance
   11.2 Training
   11.3 Documentation
12 Case studies
   12.1 Automation of the Conowingo Hydroelectric Station
   12.2 Computer-based control system at Waddell Pump-Generating
        Plant
   12.3 Retrofit of TrSngslet Hydro Power Station
   12.4 Computer-based control system at Wynoochee Hydroelectric
        Project
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications
Bibliography

Provides guidelines for the application, design concepts, and implementation of computer-based control systems for hydroelectric plant automation. This standard addresses functional capabilities, performance requirements, interface requirements, hardware considerations, and operator training. Recommendations for system testing and acceptance are also included.

Committee
CLC/SR 4
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Withdrawn

Standards Relationship
OVE EN 62270:2023 05 01 Identical
NF EN 62270 : 2004 Identical
NEN EN IEC 62270 : 2004 Identical
BS EN 62270:2004 Identical
UNE-EN 62270:2005 Identical
IEC 62270:2013 Identical
PN EN 62270 : 2006 Identical
CEI EN 62270 : 2005 Identical
NBN EN 62270 : 2005 Identical
I.S. EN 62270:2004 Identical

BS EN 61850-7-410 : 2013 COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 7-410: BASIC COMMUNICATION STRUCTURE - HYDROELECTRIC POWER PLANTS - COMMUNICATION FOR MONITORING AND CONTROL
EN 61850-7-410:2013/A1:2016 COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 7-410: BASIC COMMUNICATION STRUCTURE - HYDROELECTRIC POWER PLANTS - COMMUNICATION FOR MONITORING AND CONTROL (IEC 61850-7-410:2012/A1:2015)

IEEE 610 : 1991 COMPUTER DICTIONARY - A COMPILATION OF IEEE STANDARD COMPUTER GLOSSARIES
IEEE 802.3-2012 IEEE Standard for Ethernet
ISO/IEC 8802-3:2000 Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications
ISO/IEC 8802-4:1990 Information processing systems — Local area networks — Part 4: Token-passing bus access method and physical layer specifications
IEEE C37.90.2:2004 WITHSTAND CAPABILITY OF RELAY SYSTEMS TO RADIATED ELECTROMAGNETIC INTERFERENCE FROM TRANSCEIVERS
IEEE C37.90.1-2012 IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus
ISO/IEC 8802-5 : 1998 INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 5: TOKEN RING ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS
IEEE 1147-2005 IEEE Guide for the Rehabilitation of Hydroelectric Power Plants
IEEE 485-2010 IEEE Recommended Practice for Sizing Lead-Acid Batteries for Stationary Applications

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.