• There are no items in your cart

EN ISO 9073-12:2004

Current
Current

The latest, up-to-date edition.

Textiles - Test methods for nonwovens - Part 12: Demand absorbency (ISO 9073-12:2002)
Published date

12-22-2004

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Apparatus
6 Assembly of the apparatus
7 Preparation and conditioning of test pieces
8 Procedure
9 Expression of the results
10 Test report
Annex A (normative) Determination of flow through
        the porous medium using the data acquisition
        system
Annex B (informative) MAR calculation explanation
Annex C (informative) Precision

ISO 9073-12 describes a method for the evaluation of the absorbency of fabrics when one side is in contact with a liquid and the fabric is under mechanical pressure.This test is designed to allow comparison of absorbent materials such as nonwovens and is not intended to simulate in-use conditions of finished products.Demand absorbency is also called demand wettability.

Committee
CEN/TC 248
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

PREN 13795-1 : DRAFT 2017 SURGICAL CLOTHING AND DRAPES - REQUIREMENTS AND TEST METHODS - PART 1: SURGICAL DRAPES AND GOWNS
17/30358658 DC : 0 BS EN 13795-1 - SURGICAL CLOTHING AND DRAPES - REQUIREMENTS AND TEST METHODS - PART 1: SURGICAL DRAPES AND GOWNS
BS EN 13795:2011+A1:2013 Surgical drapes, gowns and clean air suits, used as medical devices for patients, clinical staff and equipment. General requirements for manufacturers, processors and products, test methods, performance requirements and performance levels
UNI EN 13795 : 2013 SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - GENERAL REQUIREMENTS FOR MANUFACTURERS, PROCESSORS AND PRODUCTS, TEST METHODS, PERFORMANCE REQUIREMENTS AND PERFORMANCE LEVELS
DIN EN 13795:2013-10 SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - GENERAL REQUIREMENTS FOR MANUFACTURERS, PROCESSORS AND PRODUCTS, TEST METHODS, PERFORMANCE REQUIREMENTS AND PERFORMANCE LEVELS
09/30190221 DC : 0 BS EN 13795 - SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES, FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - GENERAL REQUIREMENTS FOR MANUFACTURERS, PROCESSORS AND PRODUCTS, TEST METHODS, PERFORMANCE REQUIREMENTS AND PERFORMANCE LEVELS
I.S. EN 13795:2011 SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - GENERAL REQUIREMENTS FOR MANUFACTURERS, PROCESSORS AND PRODUCTS, TEST METHODS, PERFORMANCE REQUIREMENTS AND PERFORMANCE LEVELS
UNE-EN 13795:2011 Surgical drapes, gowns and clean air suits, used as medical devices for patients, clinical staff and equipment - General requirements for manufacturers, processors and products, test methods, performance requirements and performance levels
EN 13795:2011+A1:2013 Surgical drapes, gowns and clean air suits, used as medical devices for patients, clinical staff and equipment - General requirements for manufacturers, processors and products, test methods, performance requirements and performance levels

ISO 3696:1987 Water for analytical laboratory use — Specification and test methods
ISO 139:2005 Textiles Standard atmospheres for conditioning and testing

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.