SPECIFICATION FOR JOINTS, STOP ENDS AND OUTDOOR TERMINATIONS FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1,0 KV
Superseded date

04-01-2006

Published date

01-12-2013

1 Scope
2 Normative references
3 Definitions
4 Electrical characteristics
  4.1 Rated voltage
  4.2 Current rating
5 Compliance
  5.1 General
  5.2 Joints and stop ends
  5.3 Transition joints
  5.4 Optional tests
6 Type tests
  6.1 General
  6.2 Test samples
  6.3 Sequence of tests
  6.4 Test conditions
  6.5 Frequency and waveform of power frequency test
      voltages
  6.6 Test specifications
      6.6.1 Temperature calibration of cable
      6.6.2 Thermal stability
      6.6.3 Impulse voltage at ambient temperature
      6.6.4 A.C. voltage withstand
      6.6.5 Mechanical impact at low temperature
      6.6.6 Mechanical impact at ambient temperature
      6.6.7 Measurement of insulation resistance
      6.6.8 Load cycling
      6.6.9 Water penetration
      6.6.10 Metallic screen - short circuit current
             withstand
      6.6.11 Immersion test
      6.6.12 Examination
7 Marking and labelling, packaging and information to be
  given by the manufacturer
Annex 1 Determination of cable conductor temperature
Annex 2 Marking and labelling, packaging and information
        to be given by the manufacturer
      A2.1 Packaging
      A2.2 Marking and labelling
      A2.3 Health and safety

Specifies the performance requirements for joints, stop ends and outdoor terminations for cables of rated voltage 0,6/1,0 (1,2) kV as defined in HD 603.

Committee
TC 20
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

BS 7933-1:1998 Electric cables. Accessories. Material characterization Resinous compounds before cure and in the cured state
BS 7888-4.2:1998 LV and MV accessories for power cables with rated voltage from 0.6/1 kV (<i>U</i><sub>m</sub>=1.2 kV) up to and including 20.8/36 kV (<i>U</i><sub>m</sub>=42 kV) Test requirements for MV accessories - Accessories for cables with impregnated paper insulation
NFC 32 902 : 1998 INSULATED CABLES AND CORDS FOR INSTALLATIONS - POWER CABLE ACCESSORIES INTENDED FOR INDUSTRY, FOR RATED VOLTAGE 0,6/1(1,2) KV - TEST METHODS AND TEST REQUIREMENTS

IEC 60502:1994 Extruded solid dielectric insulated power cables for rated voltages from 1 kV up to 30 kV
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
HD 603 S1:1994/A3:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
HD 48 : 200S1 IMPULSE TESTS ON CABLES AND THEIR ACCESSORIES
HD 383 : S2 AMD 2 CONDUCTORS OF INSULATED CABLES - GUIDE TO THE DIMENSIONAL LIMITS OF CIRCULAR CONDUCTORS
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
HD 505.1.4 : 200S1 COMMON TEST METHODS FOR INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - METHODS FOR GENERAL APPLICATION - TESTS AT LOW TEMPERATURE
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.