FIXED FIREFIGHTING SYSTEMS - GAS EXTINGUISHING SYSTEMS - PART 1: DESIGN, INSTALLATION AND MAINTENANCE
Available format(s)

Hardcopy , PDF

Superseded date

04-18-2019

Language(s)

English

Published date

01-01-2008

Preview

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Use and limitations
  4.1 General
  4.2 Extinguishants
  4.3 Electrostatic discharge
  4.4 Compatibility with other extinguishants
  4.5 Temperature limitations
5 Safety
  5.1 Hazard to personnel
  5.2 Safety precautions
      5.2.1 General
      5.2.2 For normally unoccupied areas
      5.2.3 For unoccupiable areas
  5.3 Occupiable areas
  5.4 Electrical hazards
  5.5 Electrical earthing
  5.6 Electrostatic discharge
6 System design
  6.1 General
  6.2 Extinguishant supply
      6.2.1 Quantity
      6.2.2 Quality
      6.2.3 Container arrangement
      6.2.4 Storage containers
  6.3 Distribution
      6.3.1 General
      6.3.2 Piping
      6.3.3 Fittings
      6.3.4 Pipe and valve supports
      6.3.5 Valves
      6.3.6 Nozzles
      6.3.7 Pressure reducing orifice assembly
  6.4 Detection, actuation and control systems
      6.4.1 General
      6.4.2 Automatic detection
      6.4.3 Operating devices
      6.4.4 Control equipment
      6.4.5 Operating alarms and indicators
      6.4.6 Stop devices
7 Extinguishant
  7.1 General
  7.2 Specifications, plans and approvals
      7.2.1 Specifications
      7.2.2 Working documents
  7.3 System flow calculations
      7.3.1 General
      7.3.2 Balanced and unbalanced system
      7.3.3 Friction losses
      7.3.4 Pressure drop
      7.3.5 Valves and fittings
      7.3.6 Piping length
      7.3.7 Drawings
      7.3.8 Liquefied gases - Specific requirements
  7.4 Enclosures
  7.5 Extinguishant concentration requirements
      7.5.1 Flame extinguishment
  7.6 Total flooding quantity
      7.6.1 General
      7.6.2 Liquefied gases
      7.6.3 Non-liquefied gas
  7.7 Altitude adjustment
  7.8 Duration of protection
  7.9 System performance
      7.9.1 Discharge time
      7.9.2 Extended discharge
8 Commissioning and acceptance
  8.1 General
  8.2 Tests
      8.2.1 General
      8.2.2 Enclosure check
      8.2.3 Review of mechanical components
      8.2.4 Review of enclosure integrity
      8.2.5 Review of electrical components
      8.2.6 Preliminary functional tests
      8.2.7 System functional operational test
      8.2.8 Remote monitoring operations (if applicable)
      8.2.9 Control panel primary power source
      8.2.10 Completion of functional tests
  8.3 Completion certificate and documentation
9 Inspection, maintenance, testing and training
  9.1 General
  9.2 Inspection
      9.2.1 General
      9.2.2 Container
      9.2.3 Hose
      9.2.4 Enclosures
  9.3 Maintenance
      9.3.1 General
      9.3.2 User's programme of inspection
      9.3.3 Service schedule
  9.4 Training
Annex A (normative) Working documents
      A.1 General
      A.2 Working documents
      A.3 Specific details
          A.3.1 Pre-engineered systems
          A.3.2 Engineered systems
Annex B (normative) Determination of flame-extinguishing
        concentration of gaseous extinguishants by the cup
        burner method
      B.1 General
      B.2 Principle
      B.3 Requirements for apparatus
          B.3.1 General
          B.3.2 Cup
          B.3.3 Chimney
          B.3.4 Diffuser
          B.3.5 Fuel supply
          B.3.6 Manifold
          B.3.7 Air supply
          B.3.8 Extinguishant supply
          B.3.9 Delivery system
      B.4 Requirements for materials
          B.4.1 Air
          B.4.2 Fuel
          B.4.3 Extinguishant
      B.5 Procedure for flammable liquids
      B.6 Procedure for flammable gases
      B.7 Extinguishant extinguishing concentration
          B.7.1 Preferred method
          B.7.2 Alternative method
      B.8 Reporting of results
Annex C (normative) Fire extinguishment/area coverage fire test
        procedure for engineered and pre-engineered extinguishing
        units
      C.1 Requirements
      C.2 Type of test
      C.3 Extinguishing system
      C.4 Extinguishing concentration
      C.5 Nozzle distribution verification tests
          C.5.1 Nozzles minimum height/maximum area coverage test
          C.5.2 Nozzles maximum height test
      C.6 Extinguishing concentration tests
          C.6.1 Wood crib test
          C.6.2 Heptane pan test
          C.6.3 Polymeric sheet fire test
Annex D (normative) Method of evaluating inerting concentration
        of a fire extinguishant
      D.1 General
      D.2 Principle
      D.3 Apparatus
      D.4 Procedure
      D.5 Inerting concentration
Annex E (normative) Door fan test for determination of minimum
        hold time
      E.1 General
      E.2 Test for determination of predicted hold time
          E.2.1 Principle
          E.2.2 Apparatus
          E.2.3 Calibration and accuracy of apparatus
          E.2.4 Preliminary preparation
          E.2.5 Evaluation of enclosure
          E.2.6 Measurement of enclosure
          E.2.7 Test procedure
          E.2.8 Calculation
      E.3 Treatment of enclosures with predicted hold times less
          than the recommended value
          E.3.1 General
          E.3.2 Leakage areas
          E.3.3 Improved sealing of the enclosure
          E.3.4 Quantification and location of leaks
      E.4 Report
Annex F (informative) System performance verification
Annex G (informative) Safe personnel exposure guidelines
      G.1 General
      G.2 Safety
      G.3 Hazards to Personnel
          G.3.1 Agent itself
          G.3.2 Noise
          G.3.3 Turbulence
          G.3.4 Low temperature
      G.4 Halocarbon agents
          G.4.1 Toxicity of halocarbons (liquefied gases)
          G.4.2 PBPK Model
          G.4.3 Safe exposure guidelines for halocarbons
      G.5 Inert Gas (non-liquefied gas)
          G.5.1 Physiological effects of inert gas agents
          G.5.2 Safe exposure guidelines for inert gas agents
Annex H (informative) Flow calculation implementation method
        and flow calculation verification and testing for approvals
      H.1 General
      H.2 Calculation method implementation
      H.3 Minimum accuracy recommendations
          H.3.1 Physical quantities
          H.3.2 Recommended design limits to be included
                inside the flow calculation method (software)
      H.4 Recommended testing procedure for system flow
          calculation method (software) validation
          H.4.1 General
          H.4.2 System design for testing
      H.5 Pass/fail criteria
Bibliography

Describes requirements and gives recommendations for the design, installation, testing, maintenance and safety of gaseous fire fighting systems in buildings, plants or other structures, and the characteristics of the various extinguishants and types of fire for which they are a suitable extinguishing medium.

DocumentType
Standard
Pages
104
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

Standards Relationship
EN 15004-1:2008 Identical

ISO 14520-14:2015 Gaseous fire-extinguishing systems Physical properties and system design Part 14: IG-55 extinguishant
ISO 5660-1:2015 Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement)
EN 15004-6:2008 Fixed firefighting systems - Gas extinguishing systems - Part 6: Physical properties and system design of gas extinguishing systems for HFC 23 extinguishant (ISO 14520-10:2005, modified)
ISO 14520-12:2015 Gaseous fire-extinguishing systems Physical properties and system design Part 12: IG-01 extinguishant
ISO 14520-6:2016 Gaseous fire-extinguishing systems Physical properties and system design Part 6: HCFC Blend A extinguishant
EN 12094-1:2003 Fixed firefighting systems - Components for gas extinguishing systems - Part 1: Requirements and test methods for electrical automatic control and delay devices
EN 12094-13:2001/AC:2002 FIXED FIREFIGHTING SYSTEMS - COMPONENTS FOR GAS EXTINGUISHING SYSTEMS - PART 13: REQUIREMENTS AND TEST METHODS FOR CHECK VALVES AND NON-RETURN VALVES
EN 15004-4:2008 Fixed firefighting systems - Gas extinguishing systems - Part 4: Physical properties and system design of gas extinguishing systems for HFC 125 extinguishant (ISO 14520-8:2006, modified)
EN 12094-6:2006 Fixed firefighting systems - Components for gas extinguishing systems - Part 6: Requirements and test methods for non-electrical disable devices
EN 12094-10:2003 Fixed firefighting systems - Components for gas extinguishing systems - Part 10: Requirements and test methods for pressure gauges and pressure switches
EN 12094-8:2006 Fixed firefighting systems - Components for gas extinguishing systems - Part 8: Requirements and test methods for connectors
ISO 14520-10:2016 Gaseous fire-extinguishing systems Physical properties and system design Part 10: HFC 23 extinguishant
EN 12094-2:2003 Fixed firefighting systems - Components for gas extinguishing systems - Part 2: Requirements and test methods for non-electrical automatic control and delay devices
ISO 14520-13:2015 Gaseous fire-extinguishing systems Physical properties and system design Part 13: IG-100 extinguishant
EN 15004-5:2008 Fixed firefighting systems - Gas extinguishing systems - Part 5: Physical properties and system design of gas extinguishing systems for HFC 227ea extinguishant (ISO 14520-9:2006, modified)
EN 12094-4:2004 Fixed firefighting systems - Components for gas extinguishing systems - Part 4: Requirements and test methods for container valve assemblies and their actuators
EN 15004-3:2008 Fixed firefighting systems - Gas extinguishing systems - Part 3: Physical properties and system design of gas extinguishing systems for HCFC Blend A extinguishant (ISO 14520-6:2006, modified)
ISO 14520-5:2016 Gaseous fire-extinguishing systems Physical properties and system design Part 5: FK-5-1-12 extinguishant
EN 15004-2:2008 Fixed firefighting systems - Gas extinguishing systems - Part 2: Physical properties and system design of gas extinguishing systems for FK-5-1-12 extinguishant (ISO 14520-5:2006, modified)
ISO 14520-15:2015 Gaseous fire-extinguishing systems Physical properties and system design Part 15: IG-541 extinguishant
EN 12094-7:2000/A1:2005 FIXED FIREFIGHTING SYSTEMS - COMPONENTS FOR GAS EXTINGUISHING SYSTEMS - PART 7: REQUIREMENTS AND TEST METHODS FOR NOZZLES FOR CO[2] SYSTEMS
EN 12094-3:2003 Fixed firefighting systems - Components for gas extinguishing systems - Part 3: Requirements and test methods for manual triggering and stop devices
ISO 14520-9:2016 Gaseous fire-extinguishing systems Physical properties and system design Part 9: HFC 227ea extinguishant
EN 12094-11 : 2003 FIXED FIREFIGHTING SYSTEMS - COMPONENTS FOR GAS EXTINGUISHING SYSTEMS - PART 11: REQUIREMENTS AND TEST METHODS FOR MECHANICAL WEIGHING DEVICES
ISO 14520-8:2016 Gaseous fire-extinguishing systems Physical properties and system design Part 8: HFC 125 extinguishant
EN 12094-5:2006 Fixed firefighting systems - Components for gas extinguishing systems - Part 5: Requirements and test methods for high and low pressure selector valves and their actuators
EN 2:1992/A1:2004 CLASSIFICATION OF FIRES

View more information
US$163.34
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.