FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 22: RESETTABLE LINE-TYPE HEAT DETECTORS

Available format(s)

Hardcopy , PDF

Superseded date

03-17-2020

Language(s)

English

Published date

01-01-2015

Preview

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Product characteristics
5 Testing, assessments and sampling methods
6 Assessment and verification of constancy of
  performance (AVCP)
7 Classification
8 Marking, labelling and packaging
Annex A (normative) - Arrangement of the sensing
        element in the fire test room
Annex B (normative) - Flaming liquid test fires
        (TF6F, TF6 and TF6S)
Annex C (normative) - Test arrangement for the
        sensing element of linear heat detector in
        the heat tunnel
Annex D (informative) - Apparatus for mounting of the
        sensing element of linear heat detector in the
        heat tunnel
Annex E (normative) - Mounting of the sensing element
        of multipoint RLTHD in the heat tunnel
Annex F (normative) - Heat tunnel for response time and
        of multipoint RLTHD in the heat tunnel
Annex F (normative) - Heat tunnel for response time and
        response temperature measurements
Annex G (informative) - Construction of the heat
        tunnel
Annex H (normative) - Test arrangement for vibration tests
        for sensing element
Annex I (normative) - Test apparatus for impact test on the
        sensing element
Annex J (informative) - Data supplied with resettable
        line-type heat detectors
Annex ZA (informative) - Clauses of this European Standard
         addressing the provisions of the EU Construction
         Products Regulation
Bibliography

Pertains to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works.

DocumentType
Standard
Pages
86
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

Standards Relationship
EN 54-22:2015 Identical

EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 54-7:2000/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
EN 54-2:1997/A1:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
ISO 9001:2015 Quality management systems — Requirements
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

View more information
US$118.39
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.