• There are no items in your cart

IEC 60076-8:1997

Current
Current

The latest, up-to-date edition.

Power transformers - Part 8: Application guide
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French, English, French, Spanish, Castilian

Published date

10-01-1997

FOREWORD
1 General
2 Characteristic properties of different three-phase
    winding combinations and magnetic circuit designs
3 Characteristic properties and application of auto-
    connected transformers
4 Zero-sequence properties - neutral load current and earth
    fault conditions, magnetic saturation and inrush current
5 Calculation of short-circuit currents in three-winding,
    three-phase transformers (separate winding transformers
    and auto-connected transformers) with earth neutrals
6 Parallel operation of transformers in three-phase systems
7 Calculation of voltage drop for a specified load,
    three-winding transformer load loss
8 Specification of rated quantities and tapping quantities
9 Convertor applications with standard transformers
10 Guide to the measurement of losses in power transformers
Annex A Basic relations for single-phase and two-phase
          earth faults

Provides information to users about certain fundamental service characteristics of different transformer connections and magnetic circuit designs; system fault currents; parallel operation of transformers, calculation of voltage drop or rise under load; selection of rated quantities and tapping quantities; application of transformers of conventional design to convertor loading; measuring techniques etc.... Cancels and replaces IEC 60606

DevelopmentNote
Supersedes IEC 60606 (03/2001) Stability Date: 2018. (09/2017)
DocumentType
Standard
Pages
167
PublisherName
International Electrotechnical Committee
Status
Current

BS EN 60695-1-40:2014 Fire hazard testing Guidance for assessing the fire hazard of electrotechnical products. Insulating liquids
09/30187488 DC : DRAFT AUG 2009 BS EN 60076-16 - POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATION
CEI EN 60076-14 : 2014 POWER TRANSFORMERS - PART 14: LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS
07/30170365 DC : DRAFT AUG 2007 BS EN 60076-2 - POWER TRANSFORMERS - PART 2: TEMPERATURE-RISE FOR OIL-IMMERSED TRANSFORMERS
IEEE C57.16-2011 IEEE Standard for Requirements, Terminology, and Test Code for Dry-Type Air-Core Series-Connected Reactors
PD IEC/TR 60071-4:2004 Insulation co-ordination Computational guide to insulation co-ordination and modelling of electrical networks
UNE-EN 61378-1:2012 Convertor transformers -- Part 1: Transformers for industrial applications
12/30263868 DC : 0 BS EN 60076-14 - POWER TRANSFORMERS - PART 14: LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS
BS EN 60076-6:2008 Power transformers Reactors
CEI EN 61378-2 : 2002 CONVERTOR TRANSFORMERS - PART 2: TRANSFORMERS FOR HVDC APPLICATIONS
I.S. EN 60076-16:2011 POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS (IEC 60076-16:2011)
NF EN 60076-16 : 2012 POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATION
IEC TS 60076-14:2009 Power transformers - Part 14: Design and application of liquid-immersed power transformers using high-temperature insulation materials
IEC 60695-1-40:2013 Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids
EN 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
EN 61378-1:2011 Convertor transformers - Part 1: Transformers for industrial applications
IEC TS 60695-1-40:2002 Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids
17/30331680 DC : 0 BS ISO 18095 - CONDITION MONITORING AND DIAGNOSTICS OF POWER TRANSFORMERS
10/30232718 DC : 0 BS EN 60076-3 - POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR
BS EN 60076-14:2013 Power transformers Liquid-immersed power transformers using high-temperature insulation materials
CEI EN 60076-5 : 2007 POWER TRANSFORMERS - PART 5: ABILITY TO WITHSTAND SHORT CIRCUIT
BS EN 61800-4:2003 Adjustable speed electrical power drive systems General requirements. Rating specifications for a.c. power drive systems above 1000 V a.c. and not exceeding 35 kV
NF EN 61378-1 : 2014 CONVERTOR TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS
BS IEC 61378-3:2015 Converter transformers Application guide
BS PD IEC TS 60076-19 : 2013 POWER TRANSFORMERS - PART 19: RULES FOR THE DETERMINATION OF UNCERTAINTIES IN THE MEASUREMENT OF THE LOSSES ON POWER TRANSFORMERS AND REACTORS
NF EN 60076-10 : 2017 POWER TRANSFORMERS - PART 10: DETERMINATION OF SOUND LEVELS
I.S. EN 60076-2:2011 POWER TRANSFORMERS - PART 2: TEMPERATURE RISE FOR LIQUID-IMMERSED TRANSFORMERS
08/30178668 DC : DRAFT FEB 2008 BS EN 61378-1 - CONVERTER TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS
CEI EN 60076-16 : 2012 POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS
I.S. EN 60076-5:2006 POWER TRANSFORMERS - PART 5: ABILITY TO WITHSTAND SHORT-CIRCUIT
CEI EN 60076-10 : 2002 POWER TRANSFORMERS - PART 10: DETERMINATION OF SOUND LEVELS
CEI 14-42 : 2011 CONVERTER TRANSFORMERS - PART 3: APPLICATION GUIDE
CEI EN 61378-1 : 2012 CONVERTOR TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS
NF EN 60076-6 : 2008 POWER TRANSFORMERS - PART 6: REACTORS
17/30354643 DC : 0 BS EN 62933-2-1 - ELECTRIC ENERGY STORAGE (ESS) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION
I.S. EN ISO 14224:2016 PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - COLLECTION AND EXCHANGE OF RELIABILITY AND MAINTENANCE DATA FOR EQUIPMENT (ISO 14224:2016)
VDE 0532-42 : 2001 CONVERTOR TRANSFORMERS - PART 2: TRANSFORMERS FOR HVDC APPLICATIONS
CEI EN 60076-2 : 2015 POWER TRANSFORMERS - PART 2: TEMPERATURE RISE FOR LIQUID-IMMERSED TRANSFORMERS
BS EN 60076-2:2011 Power transformers Temperature rise for liquid-immersed transformers
02/210372 DC : DRAFT MAY 2002 IEC 60071-4 TR - INSULATION CO-ORDINATION - PART 4: COMPUTATIONAL GUIDE TO INSULATION CO-ORDINATION AND MODELING OF ELECTRICAL NETWORKS
13/30295873 DC : DRAFT DEC 2013 BS EN 60076-20 - POWER TRANSFORMERS - PART 20: ENERGY EFFICIENCY
BS EN 60076-16:2011 Power transformers Transformers for wind turbines applications
BS EN 60076-1:2011 Power transformers General
BS EN 50327:2003 Railway applications. Fixed installations. Harmonisation of the rated values for converter groups and tests on converter groups
12/30269145 DC : 0 BS EN 60695-1-40 ED 1.0 - FIRE HAZARD TESTING - PART 1-40: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - INSULATING LIQUIDS
UNE-EN 60076-14:2014 Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials
EN IEC 62933-2-1:2018 Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification
I.S. EN IEC 62933-2-1:2018 ELECTRICAL ENERGY STORAGE (EES) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION
I.S. EN 60695-1-40:2014 FIRE HAZARD TESTING - PART 1-40: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - INSULATING LIQUIDS
I.S. EN 60076-6:2008 POWER TRANSFORMERS - PART 6: REACTORS
I.S. EN 60076-10:2016 POWER TRANSFORMERS - PART 10: DETERMINATION OF SOUND LEVELS
IEC 62933-2-1:2017 Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification
IEC 61892-3:2012 Mobile and fixed offshore units - Electrical installations - Part 3: Equipment
IEC 61378-2:2001 Convertor transformers - Part 2: Transformers for HVDC applications
IEC 61800-4:2002 Adjustable speed electrical power drive systems - Part 4: General requirements - Rating specifications for a.c. power drive systems above 1 000 V a.c. and not exceeding 35 kV
ISO 14224:2016 Petroleum, petrochemical and natural gas industries Collection and exchange of reliability and maintenance data for equipment
DD IEC TS 60076-14 : DRAFT 2009 POWER TRANSFORMERS - PART 14: DESIGN AND APPLICATION OF LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS
UNE-EN 60695-1-40:2014 Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids
BS EN 60076-5:2006 Power transformers Ability to withstand short-circuit
BS EN 60076-10:2016 Power transformers Determination of sound levels
BS EN 61378-1:2011 Convertor transformers Transformers for industrial applications
UNE-EN 60076-16:2012 Power transformers - Part 16: Transformers for wind turbines applications
11/30253149 DC : 0 BS EN 60076-10 ED2 - POWER TRANSFORMERS - PART 10: DETERMINATION OF SOUND LEVELS
ISO 18095:2018 Condition monitoring and diagnostics of power transformers
CEI EN 60076-1 : 2015 POWER TRANSFORMERS - PART 1: GENERAL
CEI EN 60076-6 : 2015 POWER TRANSFORMERS - PART 6: REACTORS
IEC TS 60076-19:2013 Power transformers - Part 19: Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors
IEC TR 60071-4:2004 Insulation co-ordination - Part 4: Computational guide to insulation co-ordination and modelling of electrical networks
IEC 61378-1:2011 Converter transformers - Part 1: Transformers for industrial applications
UNE-EN 60076-1:2013 Power transformers - Part 1: General
IEC 60076-6:2007 Power transformers - Part 6: Reactors
IEC 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
IEC 60076-1:2011 Power transformers - Part 1: General
IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
IEC 60076-10:2016 Power transformers - Part 10: Determination of sound levels
UNE-EN 60076-2:2013 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
IEC 60076-14:2013 Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials
EN 60076-16:2011 Power transformers - Part 16: Transformers for wind turbines applications
FM 3990 : 2018 LESS OR NONFLAMMABLE LIQUID-INSULATED TRANSFORMERS
BS EN 61378-2:2001 Convertor transformers Transformers for HVDC applications
12/30275045 DC : 0 BS EN 60076-15 - POWER TRANSFORMERS - PART 15: GAS-FILLED POWER TRANSFORMER
BS IEC 61892-3:2012 Mobile and fixed offshore units. Electrical installations Equipment
CEI EN 60695-1-40 : 2014 FIRE HAZARD TESTING - PART 1-40: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - INSULATING LIQUIDS
I.S. EN 60076-14:2013 POWER TRANSFORMERS - PART 14: LIQUIDIMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS (IEC 60076-14:2013 (EQV))
IEC 61378-3:2015 Converter transformers - Part 3: Application guide
UNE-EN 60076-10:2017 Power transformers - Part 10: Determination of sound levels
I.S. EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
I.S. EN 61378-1:2011 CONVERTOR TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS (IEC 61378-1:2011)
CEI EN 61800-4 : 2003 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A/C/ POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV
I.S. EN 61800-4:2003 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A.C. POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV
IEC 60076-16:2011 Power transformers - Part 16: Transformers for wind turbine applications
BS EN ISO 14224:2016 Petroleum, petrochemical and natural gas industries. Collection and exchange of reliability and maintenance data for equipment
EN 50327 : 2003 AMD 1 2005 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
EN 61378-2:2001 Convertor transformers - Part 2: Transformers for HVDC applications
EN 60076-6:2008 Power transformers - Part 6: Reactors
EN 60076-10:2016 Power transformers - Part 10: Determination of sound levels
EN 61800-4:2003 Adjustable speed electrical power drive systems - Part 4: General requirements - Rating specifications for a.c. power drive systems above 1 000 V a.c. and not exceeding 35 kV
EN 60695-1-40:2014 Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids
EN 60076-5:2006 Power transformers - Part 5: Ability to withstand short-circuit
EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
EN 60076-14:2013 Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials
CEI 18-58 : 2013 MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 3: EQUIPMENT

IEC TR 60909-1:2002 Short-circuit currents in three-phase a.c. systems - Part 1: Factors for the calculation of short-circuit currents according to IEC 60909-0
IEC 60354:1991 Loading guide for oil-immersed power transformers
IEC 60722:1982 Guide to the lightning impulse and switching impulse testing of power transformers and reactors
IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
IEC 60076:1967 Power transformers
IEC 60076-1:2011 Power transformers - Part 1: General
IEC 60909:1988 Short-circuit current calculation in three-phase a.c. systems
IEC 60905:1987 Loading guide for dry-type power transformers
ISO 9001:2015 Quality management systems — Requirements
IEC 60289:1988 Reactors
IEC 61378-1:2011 Converter transformers - Part 1: Transformers for industrial applications
IEC 60609-2:1997 Cavitation pitting evaluation in hydraulic turbines, storage pumps and pump-turbines - Part 2: Evaluation in Pelton turbines

View more information
US$400.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.