Surge arresters - Part 6: Surge arresters containing both series and parallel gapped structures - Rated 52 kV and less
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

12-31-2021

Language(s)

English

Published date

08-14-2002

FOREWORD
INTRODUCTION
1 General
   1.1 Scope
   1.2 Normative references
2 Definitions
3 Identification and classification
   3.1 Arrester identification
   3.2 Arrester classification
4 Standard ratings
   4.1 Standard rated voltages
   4.2 Standard rated frequencies
   4.3 Standard nominal discharge currents
   4.4 Service conditions
5 Requirements
   5.1 Insulation withstand of the arrester housing
   5.2 Reference voltage
   5.3 Impulse protective levels
   5.4 Partial discharges
   5.5 Seal leakage
   5.6 Thermal stability
   5.7 Long duration current impulse withstand
   5.8 Operating duty
   5.9 Power frequency voltage versus time characteristics
        of an arrester
   5.10 Short-circuit withstand
   5.11 Disconnectors
   5.12 Requirements for internal and external grading
        components
   5.13 Power frequency sparkover
   5.14 Grading current
   5.15 Weather ageing tests
6 General procedures
   6.1 Measuring equipment and accuracy
   6.2 Reference voltage measurements
   6.3 Test samples
7 Type tests (design tests)
   7.1 General
   7.2 Insulation withstand tests on the arrester housing
   7.3 Impulse protective level tests
   7.4 Long duration current impulse withstand test
   7.5 Operating duty tests
   7.6 Tests of arrester disconnectors
   7.7 Power frequency voltage sparkover tests
   7.8 Moisture ingress tests
   7.9 Weather ageing tests
8 Routine tests and acceptance tests
   8.1 Routine tests
   8.2 Acceptance tests
Annex A (normative) Abnormal service conditions
Annex B (normative) Test to verify thermal equivalency
        between complete arrester and arrester section
Annex C (normative) Procedure to verify the power frequency
        voltage versus time characteristics of an arrester
Annex D (normative) Artificial pollution testing of
        metal-oxide surge arresters containing gapped
        structures
Annex E (informative) Typical information given with
        inquiries and tenders
Annex F (informative) Typical maximum protective levels
Bibliography
Figures
Tables

This standard basically applies to all metal-oxide surge arresters with gaps and housed in either porcelain or polymeric housings.This standard also specifies requirements and tests for metal-oxide surge arresters with internal series gaps,with rated voltages of 52KV and below.

Committee
TC 37
DevelopmentNote
Stability Date: 2017. (09/2017)
DocumentType
Standard
Pages
46
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
SANS 60099-6 : 1ED 2005(R2010) Identical

10/30210015 DC : 0 BS EN 60099-5 - SURGE ARRESTERS - SELECTION AND APPLICATION RECOMMENDATIONS
17/30339060 DC : 0 BS EN 60071-2 - INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE (PROPOSED HORIZONTAL STANDARD)
IEC 60099-5:2018 Surge arresters - Part 5: Selection and application recommendations
IEC 60099-5:2018 RLV Surge arresters - Part 5: Selection and application recommendations
CEI EN 60099-5 : 2014 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
IEC 60071-2:2018 RLV Insulation co-ordination - Part 2: Application guidelines
BS EN 60099-5:2013 Surge arresters Selection and application recommendations
EN IEC 60071-2:2018 Insulation co-ordination - Part 2: Application guidelines
I.S. EN IEC 60071-2:2018 INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDELINES
NF EN 60099-5 : 2017 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
I.S. EN 60099-5:2013 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS (IEC 60099-5:2013 (EQV))
EN IEC 60099-5:2018 Surge arresters - Part 5: Selection and application recommendations
IEC 60071-2 REDLINE : 4ED 2018 INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDELINES
16/30340451 DC : DRAFT APR 2016 BS EN 60099-5 - SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
IEC 60099-5 REDLINE : 3.0 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
I.S. EN IEC 60099-5:2018 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
IEC 60071-2:2018 Insulation co-ordination - Part 2: Application guidelines
EN 60099-5:2013 Surge arresters - Part 5: Selection and application recommendations

IEC 60060-2:2010 High-voltage test techniques - Part 2: Measuring systems
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
IEC 60099-1:1991+AMD1:1999 CSV Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems
IEC 60099-5:2013 Surge arresters - Part 5: Selection and application recommendations
IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules

View more information
US$313.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.