• There are no items in your cart

IEC 60228:2004

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Conductors of insulated cables
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

12-11-2023

Language(s)

English - French, English, French, Spanish, Castilian

Published date

11-02-2004

FOREWORD
INTRODUCTION
1 Scope
2 Terms and definitions
3 Classification
4 Materials
  4.1 Introduction
  4.2 Solid aluminium conductors
  4.3 Circular and shaped stranded aluminium conductors
5 Solid conductors and stranded conductors
  5.1 Solid conductors (class 1)
      5.1.1 Construction
      5.1.2 Resistance
  5.2 Stranded circular non-compacted conductors (class 2)
      5.2.1 Construction
      5.2.2 Resistance
  5.3 Stranded compacted circular conductors and stranded shaped
      conductors (class 2)
      5.3.1 Construction
      5.3.2 Resistance
6 Flexible conductors (classes 5 and 6)
  6.1 Construction
  6.2 Resistance
7 Check of compliance with Clauses 5 and 6
Annex A (normative) Measurement of resistance
Annex B (informative) Exact formulae for the temperature
                      correction factors
Annex C (informative) Guide to the dimensional limits of circular
                      conductors

Specifies the nominal cross-sectional areas, in the range 0,5 mm2 to 2 500 mm2, for conductors in electric power cables and cords of a wide range of types. Requirements for numbers and sizes of wires and resistance values are also included. These conductors include solid and stranded copper, aluminium and aluminium alloy conductors in cables for fixed installations and flexible copper conductors.The standard does not apply to conductors for telecommunication purposes.The applicability of this standard to a particular type of cable is as specified in the standard for the type of cable.Unless indicated to the contrary in a particular clause, this standard relates to the conductors in the finished cable and not to the conductor as made or supplied for inclusion into a cable.Informative annexes are included giving supplementary information covering temperature correction factors for resistance measurement (Annex B) and dimensional limits of circular conductors (Annex C).The principal changes with respect to the previous edition are as follows:a) the consolidation of material from IEC 60228A;b) addition of a definition for nominal cross-sectional area;c) an increase in the range of conductor sizes in Tables 1 and 2;d) addition of a note that solid aluminum alloy conductors, having the same dimensions as aluminum conductors, will have a higher resistance;e) strengthening of the recommendations for dimensional limits of compacted stranded copper conductors.

Committee
TC 20
DevelopmentNote
Supersedes IEC 60180 and IEC 60228A. (11/2004) Stability Date: 2020. (09/2017)
DocumentType
Standard
ISBN
2-8318-7706-7
Pages
37
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

NFC 32 102-15 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 15: MULTICORE CABLES INSULATED AND SHEATHED WITH HEAT RESISTANT SILICONE RUBBER
BS EN 60811-401:2012 Electric and optical fibre cables. Test methods for non-metallic materials Miscellaneous tests. Thermal ageing methods. Ageing in an air oven
DIN EN 16840:2015-04 (Draft) INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE-PHASE CURRENT 400 V, 50 HZ, AT LEAST 250 A
CEI 18-49 : 2013 ELECTRICAL INSTALLATIONS IN SHIPS - PART 350: GENERAL CONSTRUCTION AND TEST METHODS OF POWER, CONTROL AND INSTRUMENTATION CABLES FOR SHIPBOARD AND OFFSHORE APPLICATIONS
BS EN 60079-7 : 2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015)
ASTM B 682 : 2001 : R2009 : EDT 1 Standard Specification for Standard Metric Sizes of Electrical Conductors
BS 7923:2004 Electric cables. Internal gas-pressure cables and accessories for alternating voltages up to and including 275 kV (<i>U</i><sub>m</sub> = 300 kV). Requirements and test methods
UNE-EN 50525-2-72:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-72: Cables for general applications - Flat divisible cables (cords) with thermoplastic PVC insulation
IEC 62930:2017 Electric cables for photovoltaic systems with a voltage rating of 1,5 kV DC
I.S. EN 60352-7:2002 SOLDERLESS CONNECTIONS - PART 7: SPRING CLAMP CONNECTIONS - GENERAL REQUIREMENTS, TEST METHODS AND PRACTICAL GUIDANCE
IEC 60227-3:1993+AMD1:1997 CSV Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 3: Non-sheathed cables for fixed wiring
16/30337938 DC : 0 BS EN 80005-1 - UTILITY CONNECTIONS IN PORT - HIGH VOLTAGE SHORE CONNECTION (HVSC) SYSTEMS - PART 1: GENERAL REQUIREMENTS
BIS IS 694 : 2010(R2015) POLYVINYL CHLORIDE INSULATED UNSHEATHED AND SHEATHED CABLES/CORDS WITH RIGID AND FLEXIBLE CONDUCTOR FOR RATED VOLTAGES UP TO AND INCLUDING 1100 V
IEC 63010-1:2017 Halogen-free thermoplastic insulated and sheathed flexible cables of rated voltages up to and including 300/300 V - Part 1: General requirements and cables
BS EN 60998-1:2004 Connecting devices for low-voltage circuits for household and similar purposes General requirements
BS EN 50382-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
BS EN 50525-2-12:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Cables with thermoplastic PVC insulation for extensible leads
BS EN 50525-3-41:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
PREN 50525-2-83 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-83: CABLES FOR GENERAL APPLICATIONS - MULTICORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
CEI EN 50525-2-51 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
BS EN 50085-1 : 2005 CABLE TRUNKING SYSTEMS AND CABLE DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS
15/30293512 DC : 0 BS EN 16812 - TEXTILES AND TEXTILE PRODUCTS - ELECTRICALLY CONDUCTIVE TEXTILES - DETERMINATION OF THE LINEAR ELECTRICAL RESISTANCE OF CONDUCTIVE TRACKS
15/30314469 DC : 0 BS EN 62548 ED.1 - PHOTOVOLTAIC (PV) ARRAYS - DESIGN REQUIREMENTS
BS EN 50288-7:2005 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for instrumentation and control cables
CEI EN 61138 : 2009 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
CEI EN 60811-401 : 2014 ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 401: MISCELLANEOUS TESTS - THERMAL AGEING METHODS - AGEING IN AN AIR OVEN
PD IEC/TR 61916:2017 Electrical accessories. Harmonization of general rules
UNE-EN 50525-3-11:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
UNE-EN 50525-1:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements
CEI EN 50143 : 2012 CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V
UNI ISO 11862 : 2008 EARTH-MOVING MACHINERY - AUXILIARY STARTING AID ELECTRICAL CONNECTOR
NFC 32 201-3 : 1998 AMD 2 2009 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON-SHEATHED CABLES FOR FIXED WIRING
11/30233201 DC : 0 BS EN 61009-1 - RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES
I.S. EN 60999-2:2003 CONNECTING DEVICES - ELECTRICAL COPPER CONDUCTORS - SAFETY REQUIREMENTS FOR SCREW-TYPE AND SCREWLESS-TYPE CLAMPING UNITS - PART 2: PARTICULAR REQUIREMENTS FOR CLAMPING UNITS FOR CONDUCTORS ABOVE 35 MM[2] UP TO 300 MM[2] (INCLUDED)
BS EN 61995-1:2008 Devices for the connection of luminaires for household and similar purposes General requirements
08/30188796 DC : 0 BS EN 50525-2-41 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-41: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
BS EN 50143:2009 Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1000 V but not exceeding 10000 V
BS EN 50393:2015 Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV
BS IEC 62873-3-1:2016 Residual current operated circuit-breakers for household and similar use Particular requirements for RCDs with screwless-type terminals for external copper conductors
08/30188839 DC : 0 BS EN 50525-3-31 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
BS IEC 62790 : 2014 JUNCTION BOXES FOR PHOTOVOLTAIC MODULES - SAFETY REQUIREMENTS AND TESTS
BS 7769-3-2(2012) : 2012 ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 3-2: SECTIONS ON OPERATING CONDITIONS - ECONOMIC OPTIMIZATION OF POWER CABLE SIZE
BS EN 50525-2-31:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Single core non-sheathed cables with thermoplastic PVC insulation
BS EN 50085-2-3:2010 Cable trunking systems and cable ducting systems for electrical installations Particular requirements for slotted cable trunking systems intended for installation in cabinets
CEI EN 50525-2-12 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-12: CABLES FOR GENERAL APPLICATIONS - CABLES WITH THERMOPLASTIC PVC INSULATION FOR EXTENSIBLE LEADS
BS EN 50264-2-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Multicore cables
14/30289997 DC : 0 BS EN 62893-1 - CHARGING CABLES FOR ELECTRIC VEHICLES - PART 1: GENERAL REQUIREMENTS
I.S. HD 361:2003 SYSTEM FOR CABLE DESIGNATION
HD 22.14 : 200S3 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 14: CORDS FOR APPLICATIONS REQUIRING HIGH FLEXIBILITY
NF EN 61138 : 2008 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
NFC 32 201-14 : 2003 CABLES OF RATED VOLTAGE UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 14: FLEXIBLE CABLES (CORDS), INSULATED AND SHEATHED WITH HALOGEN-FREE THERMOPLASTIC COMPOUNDS
NF EN 60079-15 : 2010 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N'
IEC 60998-1:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 1: General requirements
NFC 30 202 : 2000 AMD 1 2006 SYSTEM FOR CABLE DESIGNATION
I.S. EN 62606:2013 GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES
08/30188842 DC : 0 BS EN 50525-3-41 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSS LINKED INSULATION, AND LOW EMISSION OF SMOKE
98/202332 DC : DRAFT MAY 1998 IEC 60670-1 - BOXES AND ENCLOSURES FOR ELECTRICAL ACCESSORIES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS
IEC 61009-1:2010+AMD1:2012+AMD2:2013 CSV Residual current operated circuit-breakers with integral overcurrentprotection for household and similar uses (RCBOs) - Part 1: General rules
BS EN 61442:2005 Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV)
CEI 18-52 : 2013 ELECTRICAL INSTALLATIONS IN SHIPS - PART 354: SINGLE- AND THREE-CORE POWER CABLES WITH EXTRUDED SOLID INSULATION FOR RATED VOLTAGES 6 KV (U[M] = 7,2 KV) UP TO 30 KV (U[M] = 36 KV)
EN 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
CEI EN 50525-2-22 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-22: CABLES FOR GENERAL APPLICATIONS - HIGH FLEXIBILITY BRAIDED CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
CAN/CSA-C22.2 NO. 60947-1-13 (R2018) Low-voltage switchgear and controlgear - Part 1: General rules (Tri-national standard, with UL 60947-1 and NMX-J-515-ANCE)
IEC 62026-2:2008 Low-voltage switchgear and controlgear - Controller-device interfaces (CDIs) - Part 2: Actuator sensor interface (AS-i)
BS PD IEC TR 63079 : 2017 CODE OF PRACTICE FOR HEARING-LOOP SYSTEMS (HLS)
PREN 50525-2-42 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-42: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH CROSSLINKED EVA INSULATION
CEI EN 61995-1 : 2009 DEVICES FOR THE CONNECTION OF LUMINAIRES FOR HOUSEHOLD AND SIMILAR PURPOSES - PART 1: GENERAL REQUIREMENTS
I.S. HD 22.9:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE
I.S. HD 603:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
I.S. EN 60694:1999 COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
CEI EN 50525-2-41 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-41: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
I.S. EN 60309-1:1999 PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 1: GENERAL REQUIREMENTS (IEC 60309-1:1999 (EQV))
S.R. CLC/TS 50576:2016 ELECTRIC CABLES - EXTENDED APPLICATION OF TEST RESULTS FOR REACTION TO FIRE
NFC 32 102-16 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 16: WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES
NF EN 62852 : 2015 CONNECTORS FOR DC-APPLICATION IN PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS
I.S. EN 60079-15:2010 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION &#39;N&#39;
BS EN 50539-11 : 2013 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 11: REQUIREMENTS AND TESTS FOR SPDS IN PHOTOVOLTAIC APPLICATIONS
I.S. EN 50618:2014 ELECTRIC CABLES FOR PHOTOVOLTAIC SYSTEMS
IEC 60092-352:2005 Electrical installations in ships - Part 352: Choice and installation of electrical cables
I.S. EN 61076-3-120:2016 CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-120: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR REWIRABLE POWER CONNECTORS WITH SNAP LOCKING FOR RATED VOLTAGE OF 250 V D.C. AND RATED CURRENT OF 30 A
EN 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
I.S. EN 50525-2-12:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-12: CABLES FOR GENERAL APPLICATIONS - CABLES WITH THERMOPLASTIC PVC INSULATION FOR EXTENSIBLE LEADS
I.S. EN 50620:2017 ELECTRIC CABLES - CHARGING CABLES FOR ELECTRIC VEHICLES
BS EN 50548 : 2011 JUNCTION BOXES FOR PHOTOVOLTAIC MODULES
I.S. EN 50264-3-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
IEEE 525-2007 IEEE Guide for the Design and Installation of Cable Systems in Substations
I.S. EN 60998-2-1:2004 CONNECTING DEVICES FOR LOW-VOLTAGE CIRCUITS FOR HOUSEHOLD AND SIMILAR PURPOSES - PART 2-1: PARTICULAR REQUIREMENTS FOR CONNECTING DEVICES AS SEPARATE ENTITIES WITH SCREW-TYPE CLAMPING UNITS
I.S. EN 50577:2015 ELECTRIC CABLES - FIRE RESISTANCE TEST FOR UNPROTECTED ELECTRIC CABLES (P CLASSIFICATION)
CEI EN 50525-2-72 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-72: CABLES FOR GENERAL APPLICATIONS - FLAT DIVISIBLE CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
I.S. EN 50548:2011 JUNCTION BOXES FOR PHOTOVOLTAIC MODULES
CSA C22.2 No. 61058.1 : 2009 : R2014 SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS
NFC 33 062 : 1999 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - SF6 INSULATED METAL ENCLOSED TERMINATIONS FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 500 KV (UM EQUAL TO 525 KV)
IEC/ISO/IEEE 80005-1:2012 Utility connections in port - Part 1: High Voltage Shore Connection (HVSC) Systems - General requirements
CEI EN 50525-3-11 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
NFC 32 102-13 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE
NF EN 50143 : 2009 CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V
CSA C22.2 No. 239 : 2017 CONTROL AND INSTRUMENTATION CABLES
I.S. 201-9:2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 9: CABLES FOR INSTALLATION AT LOW TEMPERATURES
ASTM F 1835 : 1997 : R2007 Standard Guide for Cable Splicing Installations
IEC 60055-1:1997+AMD1:2005 CSV Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables) - Part 1: Tests on cables and their accessories
IEC 60079-7:2015+AMD1:2017 CSV Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
IEC 62613-1:2011 Plugs, socket-outlets and ship couplers for high-voltage shore connection systems (HVSC-Systems) - Part 1: General requirements
BS EN 62026-2:2013 Low-voltage switchgear and controlgear. Controller-device interfaces (CDIs) Actuator sensor interface (AS-i)
EN IEC 60079-7:2015/A1:2018 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017)
BS EN 60519-1:2015 Safety in installations for electroheating and electromagnetic processing General requirements
17/30355856 DC : 0 BS EN 60947-2 AMENDMENT 1 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 2: CIRCUIT-BREAKERS
IEC 61230:2008 Live working - Portable equipment for earthing or earthing and short-circuiting
BS IEC 62852 : 2014 CONNECTORS FOR DC-APPLICATION IN PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS
UNE-EN 50393:2015 Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV
15/30286010 DC : 0 BS ISO 14990-1 - EARTH-MOVING MACHINERY - ELECTRICAL SAFETY OF MACHINES UTILISING ELECTRIC DRIVES AND RELATED COMPONENTS AND SYSTEMS - PART 1: GENERAL REQUIREMENTS
13/30238229 DC : 0 BS EN 62052-31 - ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TEST AND TEST CONDITIONS - PART 31: PRODUCT SAFETY REQUIREMENTS
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
IEC 60999-2:2003 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm2 up to 300 mm2 (included)
EN 62561-2:2012 Lightning Protection System Components (LPSC) - Part 2: Requirements for conductors and earth electrodes
IEC 62067:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements
EN 62052-31:2016 Electricity metering equipment (AC) - General requirements, tests and test conditions - Part 31: Product safety requirements and tests
EN 60269-1:2007/A2:2014 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014)
EN 50264-2-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
EN 61138:2007 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
CLC/TR 60079-33:2015 Explosive atmospheres - Part 33: Equipment protection by special protection 's'
EN 50525-2-51:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation
EN 61058-1:2002/A2:2008 SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS
HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
EN 50525-2-31:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation
HD 22.11 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 11: EVA CORDS AND FLEXIBLE CABLES
EN 60694:1996/A2:2001 COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
HD 603 S1:1994/A3:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
EN 50525-2-72:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-72: Cables for general applications - Flat divisible cables (cords) with thermoplastic PVC insulation
EN 50525-3-11:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
EN 50525-1:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements
EN 61442:2005 Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV)
EN 50085-2-3:2010 Cable trunking systems and cable ducting systems for electrical installations - Part 2-3: Particular requirements for slotted cable trunking systems intended for installation in cabinets
EN 50539-11 : 2013 AMD 1 2014 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 11: REQUIREMENTS AND TESTS FOR SPDS IN PHOTOVOLTAIC APPLICATIONS
EN 50085-1 : 2005 AMD 1 2013 CABLE TRUNKING SYSTEMS AND CABLE DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS
EN 60998-2-1:2004 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units
EN 60519-1:2015 Safety in installations for electroheating and electromagnetic processing - Part 1: General requirements
EN 50525-2-81:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-81: Cables for general applications - Cables with crosslinked elastomeric covering for arc welding
EN 60702-1:2002/A1:2015 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES (IEC 60702-1:2002/A1:2015)
CEI 18-64 : 2008 MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 4: CABLES
EN 50382-1 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
EN 50264-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements
EN 62606:2013/A1:2017 GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES (IEC 62606:2013/A1:2017)
EN 50525-3-31:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-31: Cables with special fire performance - Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke
HD 22.13 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE
HD 60364-5-52:2011/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS
EN 60999-1:1993/corrigendum:1997 CONNECTING DEVICES - SAFETY REQUIREMENTS FOR SCREW-TYPE AND SCREWLESS-TYPE CLAMPING UNITS FOR ELECTRICAL COPPER CONDUCTORS
EN 50264-3-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
HD 516 S2:1997/A2:2008 GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES
EN 61230:2008 LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
HD 22.12 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 12: HEAT RESISTANT EPR CORDS AND FLEXIBLE CABLES
HD 22.16 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 16: WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES
ANSI E1.29 : 2009(R2014) PRODUCT SAFETY STANDARD FOR THEATRICAL FOG GENERATORS THAT CREATE AEROSOLS OF WATER, AQUEOUS SOLUTIONS OF GLYCOL OR GLYCERIN, OR AEROSOLS OF HIGHLY REFINED ALKANE MINERAL OIL
NF EN 62196-1 : 2015 PLUGS, SOCKET-OUTLETS, VEHICLE CONNECTORS AND VEHICLE INLETS - CONDUCTIVE CHARGING OF ELECTRIC VEHICLES - PART 1: GENERAL REQUIREMENTS
13/30278215 DC : 0 BS EN 60269-1:2007+A1:2009+A2 - LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS
CEI EN 60947-7-1 : 2010 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 7-1: ANCILLARY EQUIPMENT - TERMINAL BLOCKS FOR COPPER CONDUCTORS
BS IEC 61084-2-3:2017 Cable trunking systems and cable ducting systems for electrical installations Particular requirements. Slotted cable trunking systems intended for installation in cabinets
BS IEC 62895:2017 High voltage direct current (HVDC) power transmission. Cables with extruded insulation and their accessories for rated voltages up to 320 kV for land applications. Test methods and requirements
I.S. EN 62790:2015 JUNCTION BOXES FOR PHOTOVOLTAIC MODULES - SAFETY REQUIREMENTS AND TESTS
14/30290103 DC : 0 BS EN 62895 - HIGH VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES UP TO 320KV FOR LAND APPLICATIONS - TEST METHODS AND REQUIREMENTS
I.S. EN 45510-2-9:2008 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS
BS EN 50525-2-11:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750V (U0/U) Cables for general applications. Flexible cables with thermoplastic PVC insulation
08/30188821 DC : 0 BS EN 50525-2-82 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-82: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSS LINKED ELASTOMERIC INSULATION FOR DECORATIVE CHAINS
I.S. EN 60702-1:2002 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES
I.S. EN 50525-2-81:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-81: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC COVERING FOR ARC WELDING
API RP 17I : 1996 INSTALLATION GUIDELINES FOR SUBSEA UMBILICALS
BS IEC 61084-2-4:2017 Cable trunking systems and cable ducting systems for electrical installations Particular requirements. Service poles and service posts
UNE-EN 50264-3-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
I.S. EN 60998-1:2004 CONNECTING DEVICES FOR LOW-VOLTAGE CIRCUITS FOR HOUSEHOLD AND SIMILAR PURPOSES - PART 1: GENERAL REQUIREMENTS
BS EN 60694:1997 Common specifications for high-voltage switchgear and controlgear standards
BS EN 60998-2-1:2004 Connecting devices for low-voltage circuits for household and similar purposes Particular requirements for connecting devices as separate entities with screw-type clamping units
08/30188793 DC : 0 BS EN 50525-2-31 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-31: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH THERMOPLASTIC PVC INSULATION
05/30133180 DC : 0 EN 50382-1 - RAILWAY APPLICATIONS - HIGH TEMPERATURE POWER CABLES FOR RAILWAY ROLLING STOCK AND HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
BS IEC 60287-3-2:2012 Electric cables. Calculation of the current rating Sections on operating conditions. Economic optimization of power cable size
IEC 60669-1 REDLINE : 4ED 2017 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS
BS EN 50525-3-31:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke
15/30320112 DC : 0 BS EN 61084-2-4 - CABLE TRUNKING AND DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS - PART 2-4: PARTICULAR REQUIREMENTS FOR SERVICE POLES AND SERVICE POSTS
08/30159870 DC : DRAFT APR 2008 BS EN 60800 - HEATING CABLES WITH A RATED VOLTAGE OF 300/500 V FOR COMFORT HEATING AND PREVENTION OF ICE FORMATION
IEC 61545:1996 Connecting devices - Devices for the connection of aluminium conductors in clamping units of any material and copper conductors in aluminium bodied clamping units
09/30196635 DC : 0 BS EN 60092-510 - ELECTRICAL INSTALLATIONS IN SHIPS - SPECIAL FEATURES - HIGH VOLTAGE SHORE CONNECTION SYSTEMS (HVSC-SYSTEMS)
BS EN 50525-3-11:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
04/30111859 DC : 0 IEC 62271-1 - HIGH-VOLTAGE SWITCHGEAR AND CONTROL GEAR - PART 1: COMMON SPECIFICATIONS
12/30248611 DC : 0 BS EN 62606 - GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES (AFDD)
BS EN 60999:1993 Connecting devices. Safety requirements for screw-type and screwless-type clamping units for electrical copper conductors
PREN 61008-1 : DRAFT 2011 RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCBS) - PART 1: GENERAL RULES
NF EN 50521 : 2009 AMD 1 2012 CONNECTORS FOR PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS
I.S. EN 61138:2008 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
04/30121837 DC : DRAFT SEP 2004 EN 50085-1 - CABLE TRUNKING SYSTEMS AND CABLE DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
BS EN 50525-2-42:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Single core non-sheathed cables with crosslinked EVA insulation
NF EN 60309-1 : 1999 AMD 2 2013 PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 1: GENERAL REQUIREMENTS
NF EN 60999-2 : 2003 CONNECTING DEVICES - ELECTRICAL COPPER CONDUCTORS - SAFETY REQUIREMENTS FOR SCREW-TYPE AND SCREWLESS-TYPE CLAMPING UNITS - PART 2: PARTICULAR REQUIREMENTS FOR CLAMPING UNITS FOR CONDUCTORS ABOVE 35 MM[2] UP TO 300 MM[2] (INCLUDED)
NFC 32 102-11 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 11: EVA CORDS AND FLEXIBLE CABLES
EN 50620:2017 Electric cables - Charging cables for electric vehicles
BS EN 50264-2-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Single core cables
15/30317827 DC : 0 BS EN 16840 - INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREEPHASE CURRENT 400 V, 50 HZ AND AT LEAST 250 A
IEC PAS 60092-510:2009 Electrical installations in ships - Part 510: Special features - High-voltage shore connection systems
08/30167693 DC : DRAFT NOV 2008 BS EN 50085-2-3 - CABLE TRUNKING SYSTEMS AND CABLE DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS - PART 2-3: PARTICULAR REQUIREMENTS FOR SLOTTED CABLE TRUNKING SYSTEMS INTENDED FOR INSTALLATION IN CABINETS
CEI EN 50525-2-81 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-81: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC COVERING FOR ARC WELDING
BS EN 50525-2-82:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Cables with crosslinked elastomeric insulation for decorative chains
PREN 50525-2-72 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-72: CABLES FOR GENERAL APPLICATIONS - FLAT DIVISIBLE CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
I.S. EN IEC 62613-1:2018 PLUGS, SOCKET-OUTLETS AND SHIP COUPLERS FOR HIGH-VOLTAGE SHORE CONNECTION SYSTEMS (HVSC-SYSTEMS) - PART 1: GENERAL REQUIREMENTS
IEC TR 62602:2009 Conductors of insulated cables - Data for AWG and KCMIL sizes
CEI EN 50085-2-3 : 2010 CABLE TRUNKING SYSTEMS AND CABLE DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS - PART 2-3: PARTICULAR REQUIREMENTS FOR SLOTTED CABLE TRUNKING SYSTEMS INTENDED FOR INSTALLATION IN CABINETS
CEI EN 50525-3-31 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
CEI EN 61076-3-120 : 1ED 2017 CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-120: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR REWIRABLE POWER CONNECTORS WITH SNAP LOCKING FOR RATED VOLTAGE OF 250 V D.C. AND RATED CURRENT OF 30 A
08/30188833 DC : 0 BS EN 50525-3-11 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 60998-2-2:2004 CONNECTING DEVICES FOR LOW-VOLTAGE CIRCUITS FOR HOUSEHOLD AND SIMILAR PURPOSES - PART 2-2: PARTICULAR REQUIREMENTS FOR CONNECTING DEVICES AS SEPARATE ENTITIES WITH SCREWLESS-TYPE CLAMPING UNITS
CEI EN 62561-2 : 2013 LIGHTNING PROTECTION SYSTEM COMPONENTS (LPSC) - PART 2: REQUIREMENTS FOR CONDUCTORS AND EARTH ELECTRODES
CEI 20-21/3-2 : 2007 ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 3-2: SECTIONS ON OPERATING CONDITIONS - ECONOMIC OPTIMIZATION OF POWER CABLE SIZE
I.S. EN 16840:2017 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE-PHASE CURRENT 400 V, 50 HZ, AT LEAST 250 A
PREN 61009-1 : DRAFT 2011 RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES
BS IEC 60287-1-1 : 2006 ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 1-1: CURRENT RATING EQUATIONS (100% LOAD FACTOR) AND CALCULATION OF LOSSES - GENERAL
NF EN 50214 : 2007 FLAT POLYVINYL CHLORIDE SHEATHED FLEXIBLE CABLES
IEC 62893-3:2017 Charging cables for electric vehicles for rated voltages up to and including 0,6/1 kV - Part 3: Cables for AC charging according to modes 1, 2 and 3 of IEC 61851-1 of rated voltages up to and including 450/750 V
I.S. HD 22.10:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 10: EPR INSULATED AND POLYURETHANE SHEATHED FLEXIBLE CABLES
I.S. EN 50264-2-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
ABS 0236 : 2016 GUIDE FOR CERTIFICATION OF OFFSHORE ACCESS GANGWAYS
I.S. 201-7:2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 7: CABLES WITH INCREASED HEAT RESISTANCE
IEC 61058-1:2016 Switches for appliances - Part 1: General requirements
EN 60204-1 : 2006 COR 2010 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS
I.S. EN 16812:2016 TEXTILES AND TEXTILE PRODUCTS - ELECTRICALLY CONDUCTIVE TEXTILES - DETERMINATION OF THE LINEAR ELECTRICAL RESISTANCE OF CONDUCTIVE TRACKS
UNE-IEC 60092-350:2015 Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications
I.S. EN 50539-11:2013 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 11: REQUIREMENTS AND TESTS FOR SPDS IN PHOTOVOLTAIC APPLICATIONS
I.S. EN 50085-2-3:2010 CABLE TRUNKING SYSTEMS AND CABLE DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS - PART 2-3: PARTICULAR REQUIREMENTS FOR SLOTTED CABLE TRUNKING SYSTEMS INTENDED FOR INSTALLATION IN CABINETS
I.S. HD 516:1998 GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES
I.S. EN 62852:2015 CONNECTORS FOR DC-APPLICATION IN PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS
I.S. EN 50525-3-31:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 50264-3-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
BS EN 62196-1:2014 Plugs, socket-outlets, vehicle connectors and vehicle inlets. Conductive charging of electric vehicles General requirements
I.S. EN 50525-2-42:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-42: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH CROSSLINKED EVA INSULATION
I.S. EN 61442:2005 TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (U[M] = 7,2 KV) UP TO 36 KV (U[M] = 42 KV)
CEI EN 50620 : 1ED 2017 ELECTRIC CABLES - CHARGING CABLES FOR ELECTRIC VEHICLES
I.S. EN 50525-2-11:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-11: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH THERMOPLASTIC PVC INSULATION
I.S. EN 50525-3-41:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
CSA C22.2 No. 60079-7 : 2016 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
CEI EN 50343 : 2015 RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING
CSA C22.2 No. 61058.1 : 2009 : INC : UPD 1 : 2013 SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS
UNE-CLC/TS 50576:2017 Electric cables - Extended application of test results for reaction to fire
IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
CSA C22.2 No. 60079-15 : 2016 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N'
NF EN 50264-3-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
NFC 32 201-1 : 2003 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 1: GENERAL REQUIREMENTS
CEI EN 62196-1 : 2015 PLUGS, SOCKET-OUTLETS, VEHICLE CONNECTORS AND VEHICLE INLETS - CONDUCTIVE CHARGING OF ELECTRIC VEHICLES - PART 1: GENERAL REQUIREMENTS
UNE-EN 50525-3-21:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
PREN 50525-2-41 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-41: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
UNE-EN 50525-2-81:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-81: Cables for general applications - Cables with crosslinked elastomeric covering for arc welding
I.S. 201-11:2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 11: CABLES FOR LUMINAIRES
CEI EN 50525-2-42 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-42: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH CROSSLINKED EVA INSULATION
IEEE DRAFT 525 : D15 2006 DESIGN AND INSTALLATION OF CABLE SYSTEMS IN SUBSTATIONS
I.S. 202:1989 RUBBER INSULATED CABLE AND FLEXIBLE CORDS OF RATED VOLTAGE UP TO AND INCLUDING 450/750 V
CEI EN 60079-15 : 2012 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N'
IEC 62986:2017 Plugs, socket-outlets and couplers with arcuate contacts
ASTM F 1883 : 2003 : R2008 Standard Practice for Selection of Wire and Cable Size in AWG or Metric Units
NF EN 60998-1 : 2004 CONNECTING DEVICES FOR LOW-VOLTAGE CIRCUITS FOR HOUSEHOLD AND SIMILAR PURPOSES - PART 1: GENERAL REQUIREMENTS
PREN 50525-2-11 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-11: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH THERMOPLASTIC PVC INSULATION
IEC 60840:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 30 kV (<em>U</em><sub>m</sub> = 36 kV) up to 150 kV (<em>U</em><sub>m</sub> = 170 kV) - Test methods and requirements
I.S. EN 60204-32:2008 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 32: REQUIREMENTS FOR HOISTING MACHINES
IEC 60502-2 REDLINE : 3ED 2014 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES FROM 1 KV (U[M] = 1,2 KV) UP TO 30 KV (U[M] = 36 KV) - PART 2: CABLES FOR RATED VOLTAGES FROM 6 KV (U[M] = 7,2 KV) UP TO 30 KV (U[M] = 36 KV)
IEC 60092-354:2014 Electrical installations in ships - Part 354: Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV)
IEC 60092-353:2016 Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV
NF EN 62026-2 : 2013 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONTROLLER-DEVICE INTERFACES (CDIS) - PART 2: ACTUATOR SENSOR INTERFACE (AS-I)
UNE-EN 62196-1:2015 Plugs, socket-outlets, vehicle connectors and vehicle inlets - Conductive charging of electric vehicles - Part 1: General requirements
06/30154990 DC : 0 BS EN 60204-32 - SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 32: REQUIREMENTS FOR HOISTING MACHINES
EN 60352-7:2002 Solderless connections - Part 7: Spring clamp connections - General requirements, test methods and practical guidance
EN 60947-1:2007/A2:2014 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014)
I.S. EN 61918:2013 INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES
EN 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
IEC 61058-1:2016 RLV Switches for appliances - Part 1: General requirements
BIS IS/IEC 61058-1 : 2000(R2007) SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS
BS 6360:1991 Specification for conductors in insulated cables and cords
VDE 0129-507 : 2001 ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: PLEASURE CRAFT (IEC 60092-507:2000)
VDE 0609-1 : 2000 CONNECTING DEVICES - ELECTRICAL COPPER CONDUCTORS - SAFETY REQUIREMENTS FOR SCREW-TYPE AND SCREWLESS-TYPE CLAMPING UNITS - PART 1: GENERAL REQUIREMENTS AND PARTICULAR REQUIREMENTS FOR CLAMPING UNITS FOR CONDUCTORS FROM 0.2 MM[2] UP TO 35 MM[2]
DIN EN 60999-1 : 2000 CONNECTING DEVICES - ELECTRICAL COPPER CONDUCTORS; SAFETY REQUIREMENTS FOR SCREW-TYPE AND SCREWLESS-TYPE CLAMPING UNITS - PART 1: GENERAL REQUIREMENTS AND PARTICULAR REQUIREMENTS FOR CLAMPING UNITS FOR CONDUCTORS FROM 0.2 MM[2] UP TO 35 MM[2]
BS 5467:1989 Specification for cables with thermosetting insulation for electricity supply for rated voltages of up to and including 600/1000 V and up to and including 1900/3300 V
BS 7912:2001 Power cables with XLPE insulation and metallic sheath, and their accessories, for rated voltages from 66 kV (<i>U</i><sub>m</sub>=72.5 kV) to 132kV (<i>U</i><sub>m</sub>=145kV). Requirements and test methods
12/30273098 DC : 0 BS EN 60702-1:2002+A1 - MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES
I.S. EN 50288-7:0 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 7: SECTIONAL SPECIFICATION FOR INSTRUMENTATION AND CONTROL CABLES
PREN 50525-3-11 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
PD IEC/PAS 80005-3:2014 Utility connections in port Low Voltage Shore Connection (LVSC) Systems. General requirements
BS EN 16840:2017 Inland navigation vessels. Electrical shore connection, three-phase current 400 V, 50 Hz, at least 250 A
BS EN 61238-1:2003 Compression and mechanical connectors for power cables for rated voltages up to 36 kV (<i>U</i><sub>m</sub> = 42 kV) Test methods and requirements
UNE-EN 50618:2015 Electric cables for photovoltaic systems
IEC 60364-7-712:2017 Low voltage electrical installations - Part 7-712: Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems
BS EN 62790:2015 Junction boxes for photovoltaic modules. Safety requirements and tests
BS EN 50382-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
09/30214460 DC : 0 BS EN 50548 - JUNCTION BOXES FOR PHOTOVOLTAIC MODULES
NF EN 61076-3-120 : 2017 CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-120: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR REWIRABLE POWER CONNECTORS WITH SNAP LOCKING FOR RATED VOLTAGE OF 250 V D.C. AND RATED CURRENT OF 30 A
10/30216162 DC : DRAFT DEC 2010 BS EN 62196-1 - PLUGS, SOCKET-OUTLETS, VEHICLE CONNECTORS AND VEHICLE INLETS - CONDUCTIVE CHARGING OF ELECTRIC VEHICLES - PART 1: GENERAL REQUIREMENTS
UNE-EN 50525-2-83:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation
16/30326336 DC : 0 BS EN 63010-1 - ELECTRIC CABLES - HALOGEN-FREE THERMOPLASTIC INSULATED AND SHEATHED FLEXIBLE CABLES OF RATED VOLTAGES UP TO AND INCLUDING 300/300 V - PART 1: GENERAL REQUIREMENTS
BS EN 50264-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance General requirements
BS EN 50618:2014 Electric cables for photovoltaic systems (BT(DE/NOT)258)
IEC 62821-1:2015 Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 1: General requirements
UNE-EN 61008-1:2013 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules
UNE-EN 50577:2016 Electric cables - Fire resistance test for unprotected electric cables (P classification)
S.R. CLC/TR 60079-33:2015 EXPLOSIVE ATMOSPHERES - PART 33: EQUIPMENT PROTECTION BY SPECIAL PROTECTION &#39;S&#39;
NF EN 60999-1 : 2000 CONNECTING DEVICES - ELECTRICAL COPPER CONDUCTORS - SAFETY REQUIREMENTS FOR SCREW-TYPE AND SCREW LESS-TYPE CLAMPING UNITS - PART 1: GENERAL REQUIREMENTS AND PARTICULAR REQUIREMENTS FOR CLAMPING UNITS FOR CONDUCTORS FROM 0,2 MM[2] TO 35 MM[2] (INCLUDED)
15/30326949 DC : 0 BS EN 62561-2 ED. 2 - LIGHTNING PROTECTION SYSTEM COMPONENTS (LPSC) - PART 2: REQUIREMENTS FOR CONDUCTORS AND EARTH ELECTRODES
NFC 32 102-12 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 12: HEAT RESISTANT EPR CORDS AND FLEXIBLE CABLES
13/30283464 DC : 0 BS EN 62873-3-1 ED.1 IEC 62873-3-1 ED.1 - PARTICULAR REQUIREMENTS FOR RCDS WITH SCREWLESS TYPE TERMINALS FOR EXTERNAL COPPER CONDUCTORS
NFC 33 064 : 1999 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - INDOOR OR OUTDOOR POLYMERIC TERMINATIONS, WITHOUT PORCELAIN INSULATOR, FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 150 KV (UM EQUAL TO 170 KV)
PREN 50525-2-12 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-12: CABLES FOR GENERAL APPLICATIONS - EXTENSIBLE LEADS WITH THERMOPLASTIC PVC INSULATION
BS EN 61230:2008 Live working. Portable equipment for earthing or earthing and short-circuiting
UNE-EN 16812:2016 Textiles and textile products - Electrically conductive textiles - Determination of the linear electrical resistance of conductive tracks
NF EN 61008-1 : 2013 AMD 12 2018 RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCBS) - PART 1: GENERAL RULES
BS EN 50525-2-81:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Cables with crosslinked elastomeric covering for arc welding
14/30278882 DC : 0 BS EN 60079-7 IEC 60079-7 ED. 5.0 - EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY &#39;E&#39;
EN IEC 62613-1:2018 Plugs, socket-outlets and ship couplers for high-voltage shore connection systems (HVSC-Systems) - Part 1: General requirements
IEC 62196-1:2014 Plugs, socket-outlets, vehicle connectors and vehicle inlets - Conductive charging of electric vehicles - Part 1: General requirements
CEI EN 50264-2-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
CEI EN 50525-3-41 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
CEI EN 50525-2-11 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-11: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH THERMOPLASTIC PVC INSULATION
BS EN 50264-3-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Multicore cables
08/30188771 DC : 0 BS EN 50525-2-11 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-11: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH THERMOPLASTIC PVC INSULATION
13/30277668 DC : 0 BS EN 62196-1 ED 3.0 - PLUGS, SOCKET-OUTLETS, VEHICLE CONNECTORS AND VEHICLE INLETS - CONDUCTIVE CHARGING OF ELECTRIC VEHICLES - PART 1: GENERAL REQUIREMENTS
15/30320832 DC : 0 BS EN 61084-2-3 - CABLE TRUNKING SYSTEMS AND CABLE DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS - PART 2-3: PARTICULAR REQUIREMENTS FOR SLOTTED CABLE TRUNKING SYSTEMS INTENDED FOR INSTALLATION IN CABINETS
BS EN 60999-2:2003 Connecting devices. Electrical copper conductors. Safety requirements for screw-type and screwless-type clamping units Particular requirements for clamping units for conductors above 35 mm<sup>2</sup> up to 300 mm<sup>2</sup> (included)
I.S. EN 61008-1:2012&A1:2014/ac&A2:2014...A12:2017 RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCBS) - PART 1: GENERAL RULES
I.S. EN 50214:2007 FLAT POLYVINYL CHLORIDE SHEATHED FLEXIBLE CABLES
07/30127452 DC : DRAFT AUG 2007 BS ISO 13628-5 - PETROLEUM AND NATURAL GAS INDUSTRIES - DESIGN AND OPERATION OF SUBSEA PRODUCTION SYSTEMS - PART 5: SUBSEA UMBILICALS
10/30232643 DC : 0 BS EN 62613-1 - HIGH-VOLTAGE PLUGS, SOCKET-OUTLETS AND SHIP COUPLERS FOR HIGH-VOLTAGE SHORE CONNECTION SYSTEMS (HVSC-SYSTEMS) - PART 1: GENERAL REQUIREMENTS
03/310347 DC : DRAFT JULY 2003 EN 50393 - TEST METHODS AND REQUIREMENTS FOR ACCESSORIES FOR USE ON DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1,0 (1,2) KV
BS EN 61076-3-120:2016 Connectors for electronic equipment. Product requirements Rectangular connectors. Detail specification for rewirable power connectors with snap locking for rated voltage of 250 V d.c. and rated current of 30 A
BS EN 50525-2-83:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Multicore cables with crosslinked silicone rubber insulation
BS EN 60352-7:2002 Solderless connections Spring clamp connections. General requirements, test methods and practical guidance
UNE-IEC 60092-353:2017 Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV
UNE-EN 50525-2-42:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-42: Cables for general applications - Single core non-sheathed cables with crosslinked EVA insulation
API SPEC 17E : 2017 SPECIFICATION FOR SUBSEA UMBILICALS
BS EN 50343 : 2014 RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING
CEI EN 50264-2-2 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
I.S. HD 384.5.523:2002 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SECTION 523: CURRENT-CARRYING CAPACITIES IN WIRING SYSTEMS
UNE-EN 50264-2-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
IEC 60364-5-52:2009 Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems
IEC 62821-3:2015 Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 3: Flexible cables (cords)
UNE-EN 62561-2:2012 Lightning Protection System Components (LPSC) - Part 2: Requirements for conductors and earth electrodes
EN 50577:2015 Electric cables - Fire resistance test for unprotected electric cables (P classification)
NFC 32 102-9 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE
I.S. EN 62561-2:2012 LIGHTNING PROTECTION SYSTEM COMPONENTS (LPSC) - PART 2: REQUIREMENTS FOR CONDUCTORS AND EARTH ELECTRODES (IEC 62561-2:2012 (MOD))
C22.2 NO. 188-18 Splicing wire connectors (Trinational standard with UL 486C and NXM-J- 548-ANCE)
IEC TR 61916:2017 Electrical accessories - Harmonization of general rules
IEC 60669-1:2017 RLV Switches for household and similar fixed-electrical installations - Part 1: General requirements
UNE-EN 50525-2-11:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation
I.S. EN 50525-1:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 1: GENERAL REQUIREMENTS
IEC 60364-7-712 REDLINE : 2ED 2017 LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-712: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SOLAR PHOTOVOLTAIC (PV) POWER SUPPLY SYSTEMS
I.S. EN 50382-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
I.S. EN 60079-7:2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
API 17E REDLINE : 2010 SPECIFICATION FOR SUBSEA UMBILICALS
EN 60811-401:2012/A1:2017 ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 401: MISCELLANEOUS TESTS - THERMAL AGEING METHODS - AGEING IN AN AIR OVEN (IEC 60811-401:2012/A1:2017)
I.S. HD 60364-5-52:2011 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS
I.S. EN 61058-1:2002 SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS
I.S. HD 22.11:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 11: EVA CORDS AND FLEXIBLE CABLES
CEI 20-21/1-1 : 2007 ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 1-1: CURRENT RATING EQUATIONS (100% LOAD FACTOR) AND CALCULATION OF LOSSES - GENERAL
BS EN 62271-1:2017 High-voltage switchgear and controlgear Common specifications for alternating current switchgear and controlgear
NFC 32 102-10 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 10: EPR INSULATED AND POLYURETHANE SHEATHED FLEXIBLE CABLES
BS EN 60702-1 : 2002 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES
IEC TR 60092-370:2009 Electrical installations in ships - Part 370: Guidance on the selection of cables for telecommunication and data transfer including radio-frequency cables
CEI EN 50525-2-83 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-83: CABLES FOR GENERAL APPLICATIONS - MULTICORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
I.S. EN 61439-1:2011 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES (IEC 61439-1:2011)
I.S. EN 50264-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
IEC 60998-2-1:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units
IEC 60245-8:1998+AMD1:2003+AMD2:2011 CSV Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 8: Cords for applications requiring high flexibility
BIS IS/IEC 62271-1 : 2007 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS
CEI EN 50264-3-2 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
IEC 60245-4:2011 Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables
CSA C22.2 No. 61058.1 : 2009 SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS
UNE-EN 62790:2015 Junction boxes for photovoltaic modules - Safety requirements and tests
BS EN 60079-15:2010 Explosive atmospheres Equipment protection by type of protection \'n\'
BS IEC 61084-2-1:2017 Cable trunking systems and cable ducting systems for electrical installations Particular requirements. Cable trunking systems and cable ducting systems intended for mounting on walls and ceilings
PD IEC/TR 60601-4-3:2015 Medical electrical equipment Guidance and interpretation. Considerations of unaddressed safety aspects in the third edition of IEC 60601-1 and proposals for new requirements
I.S. 201-8:2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 8: SINGLE CORE NON-SHEATHED CABLES FOR DECORATIVE CHAINS
IEC 60079-33:2012 Explosive atmospheres - Part 33: Equipment protection by special protection 's'
CEI EN 60999-2 : 2005 CONNECTING DEVICES - ELECTRICAL COPPER CONDUCTORS - SAFETY REQUIREMENTS FOR SCREW-TYPE AND SCREWLESS-TYPE CLAMPING UNITS - PART 2: PARTICULAR REQUIREMENTS FOR CLAMPING UNITS FOR CONDUCTORS ABOVE 35 MM[2] UP TO 300 MM[2] (INCLUDED)
NF EN 50382-2 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
NF EN 50395 : 2005 AMD 1 2012 ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
IEC 60227-6:2001 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 6: Lift cables and cables for flexible connections
IEC 60800:2009 Heating cables with a rated voltage of 300/500 V for comfort heating and prevention of ice formation
IEC 60669-1:2017 Switches for household and similar fixed-electrical installations - Part 1: General requirements
IEC 61084-2-1:2017 Cable trunking systems and cable ducting systems for electrical installations - Part 2-1: Particular requirements - Cable trunking systems and cable ducting systems intended for mounting on walls and ceilings
I.S. EN 61984:2009 CONNECTORS - SAFETY REQUIREMENTS AND TESTS
IEC 60092-353 REDLINE : 4ED 2016 ELECTRICAL INSTALLATIONS IN SHIPS - PART 353: POWER CABLES FOR RATED VOLTAGES 1 KV AND 3 KV
IEC 60204-1:2016 Safety of machinery - Electrical equipment of machines - Part 1: General requirements
IEC TS 62100:2004 Cables for aeronautical ground lighting primary circuits
IEC 61238-1:2003 Compression and mechanical connectors for power cables for rated voltages up to 30 kV (Um = 36 kV) - Part 1: Test methods and requirements
IEC 62067 : 2.0EN+(REDLINE+VERSION) POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 150 KV (U[M] = 170 KV) UP TO 500 KV (U[M] = 550 KV) - TEST METHODS AND REQUIREMENTS
I.S. EN 60204-1:2006 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS
IEC 61918:2013 Industrial communication networks - Installation of communication networks in industrial premises
IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules
IEEE 2030.1.1-2015 IEEE Standard Technical Specifications of a DC Quick Charger for Use with Electric Vehicles
C22.2 NO. 75-17 Thermoplastic insulated wires and cables (Trinational standard with UL 83 and NMX-J-010-ANCE-2017)
04/30123347 DC : DRAFT OCT 2004 IEC 61439-1 - LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES
IEC 60998-2-2:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units
EN 61009-1:2012/A12:2016 RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES
UNE-EN 50521:2010 Connectors for photovoltaic systems - Safety requirements and tests
CEI EN 60519-1 : 2016 SAFETY IN INSTALLATIONS FOR ELECTROHEATING AND ELECTROMAGNETIC PROCESSING - PART 1: GENERAL REQUIREMENTS
CEI EN 62026-2 : 2013 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONTROLLER-DEVICE INTERFACES (CDIS) - PART 2: ACTUATOR SENSOR INTERFACE (AS-I)
EN 62790:2015 Junction boxes for photovoltaic modules - Safety requirements and tests
EN 60898-1:2003/A13:2012 ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002, MODIFIED)
IEC 60092-353:2016 RLV Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV
UNE-HD 620.10E:2012 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 10: XLPE insulated single core and 3 core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 10E-1, 10E-3, 10E-4 and 10E-5).
UNE-EN 60204-1:2007 Safety of machinery - Electrical equipment of machines - Part 1: General requirements
HD 361 : S3 AMD 1 2006 SYSTEM FOR CABLE DESIGNATION
UNE-HD 620.9E:2012 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 9: HEPR insulated single core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 9E-1, 9E-3, 9E-4 and 9E-5).
BS 6346:1989 Specification for PVC-insulated cables for electricity supply
EN 60898-1:2003/A13:2012 ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002, MODIFIED)
EN 45510-2-9:2008 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS
UNE-EN 50264-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 1: General requirements
CEI EN 61442 : 2006 TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (U[M] = 7,2 KV) UP TO 36 KV (U[M] = 42 KV)
I.S. EN 60947-7-1:2009 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 7-1: ANCILLARY EQUIPMENT - TERMINAL BLOCKS FOR COPPER CONDUCTORS
05/30128938 DC : DRAFT FEB 2005 IEC 61138 ED.3 - CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
08/30188836 DC : 0 BS EN 50525-3-21 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSS LINKED INSULATION, AND LOW EMISSION OF SMOKE
08/30188826 DC : 0 BS EN 50525-2-83 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-83: CABLES FOR GENERAL APPLICATIONS - MULTICORE CABLES WITH CROSS LINKED SILICONE RUBBER INSULATION
14/30311585 DC : 0 BS EN 61076-3-120 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-120: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR REWIRABLE POWER CONNECTOR WITH SNAP LOCKING FOR 250 V D.C. AND RATED CURRENT OF 30A
BS EN 16812:2016 Textiles and textile products. Electrically conductive textiles. Determination of the linear electrical resistance of conductive tracks
BS EN 50525-2-22:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. High flexibility braided cables with crosslinked elastomeric insulation
BS ISO/IEC/IEEE 80005-1:2012 Utility connections in port High Voltage Shore Connection (HVSC) Systems. General requirements
CEI EN 60999-1 : 2000 CONNECTING DEVICES - ELECTRICAL COPPER CONDUCTORS - SAFETY REQUIREMENTS FOR SCREW-TYPE AND SCREWLESS-TYPE CLAMPING UNITS PART 1: GENERAL REQUIREMENTS AND PARTICULAR REQUIREMENTS FOR CLAMPING UNITS FOR CONDUCTORS FROM 0,2 MM[2] UP TO 35 MM[2] (INCLUDED)
EA 0052:2014 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3).
BS 7922:2004 Electric cables. Fluid-filled, paper- and PPL-insulated, metal-sheathed cables and accessories for alternating voltages up to and including 400 kV (<i>U</i><sub>m</sub> = 420 kV). Requirements and test methods
UNI EN ISO 13628-5 : 2010 PETROLEUM AND NATURAL GAS INDUSTRIES - DESIGN AND OPERATION OF SUBSEA PRODUCTION SYSTEMS - PART 5: SUBSEA UMBILICALS
NFC 32 102-1 : 2003 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 1: GENERAL REQUIREMENTS
BS 7769-1.1:1997 Electric cables. Calculation of the current rating. Current rating equations (100% load factor) and calculation of losses General
12/30235292 DC : 0 BS EN 50343 - RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING
BS EN 50620:2017 Electric cables. Charging cables for electric vehicles (BT(DE/NOT)259)
BS EN 60947-1 : 2007 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES
BS EN 50525-2-41:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Single core cables with crosslinked silicone rubber insulation
BS EN 50525-3-21:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
08/30188779 DC : 0 BS EN 50525-2-12 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-12: CABLES FOR GENERAL APPLICATIONS - EXTENSIBLE LEADS WITH THERMOPLASTIC PVC INSULATION
11/30233197 DC : 0 BS EN 61008-1 - RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCBS) - PART 1: GENERAL RULES
ASTM B 682 : 2001 : R2009 Standard Specification for Standard Metric Sizes of Electrical Conductors
IEC 62873-3-3:2016 Residual current operated circuit-breakers for household and similar use - Part 3-3: Specific requirements for RCDs with screw-type terminals for external untreated aluminium conductors and with aluminium screw-type terminals for use with copper or with aluminium conductors
NFC 32 102-8 : 99 AMD 2 2004 RUBBER INSULATED CABLES OR RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 8: POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLE FOR DECORATIVE CHAINS
UNE-EN 50264-3-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
UNE-EN 50525-2-12:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-12: Cables for general applications - Cables with thermoplastic PVC insulation for extensible leads
EN IEC 61058-1:2018 Switches for appliances - Part 1: General requirements
BS EN 50525-2-21:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Flexible cables with crosslinked elastomeric insulation
12/30262193 DC : 0 BS EN 50393 - TEST METHODS AND REQUIREMENTS FOR ACCESSORIES FOR USE ON DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1,0 (1,2) KV
PREN 50525-2-21 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
CEI EN 50525-2-21 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
I.S. HD 632:2016 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
08/30188764 DC : 0 BS EN 50525-1 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - CABLES FOR GENERAL APPLICATIONS
PREN 50525-2-31 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-31: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH THERMOPLASTIC PVC INSULATION
PREN 50525-2-51 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
IEC 60502-2:2014 RLV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV)
BS EN 50264-3-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Single core cables
BS EN 50214:2006 Flat polyvinyl chloride sheathed flexible cables
CEI EN 50264-3-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
CEI EN 60998-1 : 2005 CONNECTING DEVICES FOR LOW-VOLTAGE CIRCUITS FOR HOUSEHOLD AND SIMILAR PURPOSES - PART 1: GENERAL REQUIREMENTS
14/30313775 DC : 0 BS EN 62893-3 - CHARGING CABLES FOR ELECTRIC VEHICLES - PART 3: CABLES FOR AC CHARGING ACCORDING TO MODES 1, 2 AND 3 OF IEC 61851-1
08/30188788 DC : 0 BS EN 50525-2-22 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-22: CABLES FOR GENERAL APPLICATIONS - HIGH FLEXIBILITY BRAIDED CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
BS EN 50525-2-51:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Oil resistant control cables with thermoplastic PVC insulation
ASTM F 1883 : 2003 Standard Practice for Selection of Wire and Cable Size in AWG or Metric Units
BS EN 60998-2-2:2004 Connecting devices for low voltage circuits for household and similar purposes Particular requirements for connecting devices as separate entities with screwless-type clamping units
NF ISO 11862 : 2005 EARTH-MOVING MACHINERY - AUXILIARY STARTING AID ELECTRICAL CONNECTOR
04/30111288 DC : DRAFT MAR 2004 EN 50214 - FLAT POLYVINYL CHLORIDE SHEATHED FLEXIBLE CABLES
05/30133183 DC : 0 EN 50382-2 - RAILWAY APPLICATIONS - HIGH TEMPERATURE POWER CABLES FOR RAILWAY ROLLING STOCK AND HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREE C
01/202703 DC : DRAFT APRIL 2001 IEC 60092-354 ED.2 - ELECTRICAL INSULATION IN SHIPS - PART 354: SINGLE AND THREE CORE POWER CABLES WITH EXTRUDED SOLID INSULATION FOR RATED VOLTAGES 6 KV (UM EQUALS 7.2 KV) UP TO 30 KV (UM EQUALS 36 KV)
CEI EN 50264-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
BS ISO 13628-5:2002 Petroleum and natural gas industries. Design and operation of subsea production systems Subsea umbilicals
PREN 50525-2-82 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-82: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC INSULATION FOR DECORATIVE CHAINS
08/30188799 DC : 0 BS EN 50525-2-42 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-42: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH CROSS LINKED EVA INSULATION
I.S. EN 50525-2-83:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-83: CABLES FOR GENERAL APPLICATIONS - MULTICORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
07/30170224 DC : DRAFT AUG 2007 BS EN 61230 - LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
03/317673 DC : 0 IEC 61995-1 - DEVICES FOR THE CONNECTION OF LUMINAIRES FOR HOUSEHOLD AND SIMILAR PURPOSES - PART 1: GENERAL REQUIREMENTS
VDE 0472-501 : 1983 TESTING OF CABLES, WIRES AND FLEXIBLE CORDS; CONDUCTOR RESISTANCE
IEC 60227-7:1995+AMD1:2003+AMD2:2011 CSV Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 7: Flexible cables screened and unscreened with two or more conductors
BS EN 60998-2-3:2004 Connecting devices for low-voltage circuits for household and similar purposes Particular requirements for connecting devices as separate entities with insulation-piercing clamping units
I.S. 201-3:2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: SINGLE CORE NON-SHEATHED CABLES FOR FIXED WIRING
BS EN 60269-1 : 2007 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS
06/30157050 DC : 0 BS EN 60947-7-1 AMD 1 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 7-1: ANCILLARY EQUIPMENT - TERMINAL BLOCKS FOR COPPER CONDUCTORS
ASTM B 682 : 2001 : R2016 Standard Specification for Standard Metric Sizes of Electrical Conductors
C22.2 NO. 38-18 THERMOSET-INSULATED WIRES AND CABLES
I.S. EN 60598-1:2015 LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS
IEC 60840 REDLINE : 4.0 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 30 KV (U[M] = 36 KV) UP TO 150 KV (U[M] = 170 KV) - TEST METHODS AND REQUIREMENTS
ISO 11862:1993 Earth-moving machinery — Auxiliary starting aid electrical connector
PREN 50525-2-22 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-22: CABLES FOR GENERAL APPLICATIONS - HIGH FLEXIBILITY BRAIDED CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
CEI EN 50525-3-21 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
EN 61995-1:2008/A1:2017 DEVICES FOR THE CONNECTION OF LUMINAIRES FOR HOUSEHOLD AND SIMILAR PURPOSES - PART 1: GENERAL REQUIREMENTS (IEC 61995-1:2005/A1:2016)
BS EN 61058-1 : 2002 SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS
ISO 14990-1:2016 Earth-moving machinery — Electrical safety of machines utilizing electric drives and related components and systems — Part 1: General requirements
I.S. EN 62271-1:2017 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS FOR ALTERNATING CURRENT SWITCHGEAR AND CONTROLGEAR
I.S. EN 50382-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
I.S. EN 60999-1:2003 CONNECTING DEVICES - ELECTRICAL COPPER CONDUCTORS - SAFETY REQUIREMENTS FOR SCREW-TYPE AND SCREWLESS-TYPE CLAMPING UNITS - PART 1: GENERAL REQUIREMENTS AND PARTICULAR REQUIREMENTS FOR CLAMPING UNITS FOR CONDUCTORS FROM 0,2 MM[2] UP TO 35 MM[2] (INCLUDED)
ASTM F 1883 : 2003 : R2013 Standard Practice for Selection of Wire and Cable Size in AWG or Metric Units
I.S. EN 50525-3-11:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 50525-2-72:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-72: CABLES FOR GENERAL APPLICATIONS - FLAT DIVISIBLE CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
NF EN 50264-2-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
I.S. EN 60898-1:2003 ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002 (MOD))
EN 60598-1:2015/A1:2018 LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS
NF EN 50618 : 2015 ELECTRIC CABLES FOR PHOTOVOLTAIC SYSTEMS
ASTM B 682 : 2001 Standard Specification for Standard Metric Sizes of Electrical Conductors
S.R. HD 60364-5-52:2011 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS
I.S. EN 60519-1:2015 SAFETY IN INSTALLATIONS FOR ELECTROHEATING AND ELECTROMAGNETIC PROCESSING - PART 1: GENERAL REQUIREMENTS
I.S. EN 60811-401:2012 ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 401: MISCELLANEOUS TESTS - THERMAL AGEING METHODS - AGEING IN AN AIR OVEN
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
API STD 17F : 2017 SUBSEA PRODUCTION CONTROL SYSTEMS
UNE-EN 60079-7:2016 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
I.S. EN 50525-2-82:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-82: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC INSULATION FOR DECORATIVE CHAINS
CEI EN 50525-2-82 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-82: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC INSULATION FOR DECORATIVE CHAINS
UNE-EN 62852:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
ASTM F 1835 : 1997 : R2002 Standard Guide for Cable Splicing Installations
ASTM F 1835 : 1997 Standard Guide for Cable Splicing Installations
IEC 60227-1:2007 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements
EN 62026-2:2013 Low-voltage switchgear and controlgear - Controller-device interfaces (CDIs) - Part 2: Actuator sensor interface (AS-i)
IEC 61138:2007 Cables for portable earthing and short-circuiting equipment
IEC 60245-5:1994 Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 5: Lift cables
I.S. EN 50525-2-31:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-31: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH THERMOPLASTIC PVC INSULATION
IEC 61084-2-3:2017 Cable trunking systems and cable ducting systems for electrical installations - Part 2-3: Particular requirements - Slotted cable trunking systems intended for installation in cabinets
IEC 60092-350:2014 Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications
I.S. EN 50343:2014 RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING
I.S. HD 22.16:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 16: WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES
I.S. EN 61230:2008 LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
IEC 60287-1-1:2006+AMD1:2014 CSV Electric cables - Calculation of the current rating - Part 1-1:Current rating equations (100 % load factor) and calculation of losses - General
I.S. HD 620:2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
IEC 61995-1:2005+AMD1:2016 CSV Devices for the connection of luminaires for household and similarpurposes - Part 1: General requirements
IEC 62955:2018 Residual direct current detecting device (RDC-DD) to be used for mode 3 charging of electric vehicles
IEC 60364-5-523:1999 Electrical installations of buildings - Part 5: Selection and erection of electrical equipment - Section 523: Current-carrying capacities in wiring systems
S.R. CLC/TR 50480:2011 DETERMINATION OF CROSS-SECTIONAL AREA OF CONDUCTORS AND SELECTION OF PROTECTIVE DEVICES
I.S. EN 50525-2-51:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
IEC 60141-1:1993 Tests on oil-filled and gas-pressure cables and their accessories - Part 1: Oil-filled, paper or polypropylene paper laminate insulated, metal-sheathed cables and accessories for alternating voltages up to and including 500 kV
IEC 62052-31:2015 Electricity metering equipment (AC) - General requirements, tests and test conditions - Part 31: Product safety requirements and tests
IEC 60519-1:2015 Safety in installations for electroheating and electromagnetic processing - Part 1: General requirements
IEC 60309-1:1999+AMD1:2005+AMD2:2012 CSV Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements
PD IEC/TS 62548:2013 Photovoltaic (PV) arrays. Design requirements
BS EN 61918:2013 Industrial communication networks. Installation of communication networks in industrial premises
BS EN 61984:2009 Connectors. Safety requirements and tests
IEC 61984:2008 Connectors - Safety requirements and tests
IEC 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
14/30238347 DC : 0 BS EN 60204-1 ED 6.0 - SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS
IEC 60811-401:2012+AMD1:2017 CSV Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven
IEC 60998-2-3:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units
EN 60669-1:2018 Switches for household and similar fixed electrical installations - Part 1: General requirements
08/30195018 DC : DRAFT DEC 2008 BS EN 60204-33 - SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 33: REQUIREMENTS FOR SEMICONDUCTOR FABRICATION EQUIPMENT
PD CLC/TR 50480:2011 Determination of cross-sectional area of conductors and selection of protective devices
EN 62852:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
UNE-EN 61009-1:2013 Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules
14/30272356 DC : 0 BS EN 60669-1 - SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED-ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
IEC 60309-2:1999+AMD1:2005+AMD2:2012 CSV Plugs, socket-outlets and couplers for industrial purposes - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories
UNE-EN 50525-2-41:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-41: Cables for general applications - Single core cables with crosslinked silicone rubber insulation
IEC 61058-2-4:1995+AMD1:2003 CSV Switches for appliances - Part 2-4: Particular requirements for independently mounted switches
09/30204029 DC : 0 BS EN 61439-1 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES
IEC 60947-7-1:2009 Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors
ISO 13628-5:2009 Petroleum and natural gas industries Design and operation of subsea production systems Part 5: Subsea umbilicals
IEC TR 60890:2014 A method of temperature-rise verification of low-voltage switchgear and controlgear assemblies by calculation
IEC 60702-1:2002+AMD1:2015 CSV Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables
BS EN 60898-1 : 2003 ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION
BS EN 62852:2015 Connectors for DC-application in photovoltaic systems. Safety requirements and tests
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
IEC 60352-7:2002 Solderless connections - Part 7: Spring clamp connections - General requirements, test methods and practical guidance
UNE-EN 50525-2-31:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation
PD CLC/TR 60079-33:2015 Explosive atmospheres Equipment protection by special protection \'s\'
UL 83:16ED 2017-07 Standard for Thermoplastic-Insulated Wires and Cables
IEC 61076-3-120:2016 Connectors for electronic equipment - Product requirements - Part 3-120: Rectangular connectors - Detail specification for rewirable power connectors with snap locking for rated voltage of 250 V d.c. and rated current of 30 A
BS EN 50521 : 2009 CONNECTORS FOR PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS
IEC 61439-1:2020 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
BS IEC 60079-33 : 2012 EXPLOSIVE ATMOSPHERES - PART 33: EQUIPMENT PROTECTION BY SPECIAL PROTECTION &#39;S&#39;
BS EN 61009-1 : 2012 RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES
BS ISO 14990-1:2016 Earth-moving machinery. Electrical safety of machines utilizing electric drives and related components and systems General requirements
IEC 60999-1:1999 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included)
BS IEC 62548:2016 Photovoltaic (PV) arrays. Design requirements
IEC 60884-1:2002+AMD1:2006+AMD2:2013 CSV Plugs and socket-outlets for household and similar purposes - Part1: General requirements
UNE-EN 50525-2-82:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains
16/30301661 DC : 0 BS EN 61439-1 ED3.0 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES
UNE-EN 60811-401:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven
UNE-IEC 61892-4:2016 Mobile and fixed offshore units - Electrical installations - Part 4: Cables
07/30153021 DC : 0 BS IEC 60204-33 - SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 33: REQUIREMENTS FOR SEMICONDUCTOR FABRICATION EQUIPMENT
EN 62196-1:2014 Plugs, socket-outlets, vehicle connectors and vehicle inlets - Conductive charging of electric vehicles - Part 1: General requirements
EN 50525-2-83:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation
EN 45510-2-9 : 2008 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS
EN 50525-2-41:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-41: Cables for general applications - Single core cables with crosslinked silicone rubber insulation
EN 50393:2015 Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV
EN 50525-2-22:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-22: Cables for general applications - High flexibility braided cables with crosslinked elastomeric insulation
EN 16812:2016 Textiles and textile products - Electrically conductive textiles - Determination of the linear electrical resistance of conductive tracks
EN 16840:2017 Inland navigation vessels - Electrical shore connection, three-phase current 400 V, 50 Hz, at least 250 A
EN ISO 13628-5:2009 Petroleum and natural gas industries - Design and operation of subsea production systems - Part 5: Subsea umbilicals (ISO 13628-5:2009)
PREN 50525-3-41 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
BS IEC 62873-3-3:2016 Residual current operated circuit-breakers for household and similar use Specific requirements for RCDs with screw-type terminals for external untreated aluminium conductors and with aluminium screw-type terminals for use with copper or with aluminium conductors
I.S. EN 50525-2-22:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-22: CABLES FOR GENERAL APPLICATIONS - HIGH FLEXIBILITY BRAIDED CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
04/30114758 DC : 0 IEC 60092-350 ED.3 - ELECTRICAL INSTALLATION IN SHIP - PART 350: SHIPBOARD POWER CABLES - GENERAL CONSTRUCTION AND TEST REQUIREMENTS
07/30164212 DC : 0 BS EN 50143 - CABLES FOR SIGNS AND LUMINOUS-DISCHARGE TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V
I.S. EN ISO 13628-5:2009 PETROLEUM AND NATURAL GAS INDUSTRIES - DESIGN AND OPERATION OF SUBSEA PRODUCTION SYSTEMS - PART 5: SUBSEA UMBILICALS
UNE-EN 60079-15:2013 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
I.S. EN 61995-1:2008 DEVICES FOR THE CONNECTION OF LUMINAIRES FOR HOUSEHOLD AND SIMILAR PURPOSES - PART 1: GENERAL REQUIREMENTS
I.S. EN 62026-2:2013 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONTROLLER-DEVICE INTERFACES (CDIS) - PART 2: ACTUATOR SENSOR INTERFACE (AS-I) (IEC 62026-2:2008 (MOD))
IEC 61084-2-4:2017 Cable trunking systems and cable ducting systems for electrical installations - Part 2-4: Particular requirements - Service poles and service posts
UNE-EN 50525-3-41:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
BS EN 50577:2015 Electric cables. Fire resistance test for unprotected electric cables (P classification)
BS EN 62561-2:2012 Lightning Protection System Components (LPSC) Requirements for conductors and earth electrodes
I.S. EN 50525-3-21:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
08/30188783 DC : 0 BS EN 50525-2-21 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
CEI EN 50214 : 2007 FLAT POLYVINYL CHLORIDE SHEATHED FLEXIBLE CABLES
BS EN 60999-1:2000 Connecting devices. Electrical copper conductors. Safety requirements for screw-type and screwless-type clamping units General requirements and particular requirements for clamping units for conductors from 0,2 mm<sup>2</sup> up to 35 mm<sup>2</sup> (included)
BS EN 50525-2-72:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Flat divisible cables (cords) with thermoplastic PVC insulation
UNE-EN 50525-2-22:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-22: Cables for general applications - High flexibility braided cables with crosslinked elastomeric insulation
PREN 50525-3-31 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
13/30294866 DC : 0 BS EN 61058-1 - SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS
15/30265353 DC : 0 BS EN 62271-1 ED 2 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS FOR ALTERNATING CURRENT SWITCHGEAR AND CONTROLGEAR
08/30188813 DC : 0 BS EN 50525-2-72 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-72: CABLES FOR GENERAL APPLICATIONS - FLAT DIVISIBLE CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
BS EN 50525-1:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) General requirements
16/30339801 DC : 0 BS EN 63052 - POWER FREQUENCY OVERVOLTAGE PROTECTIVE DEVICES FOR HOUSEHOLD AND SIMILAR APPLICATIONS (POP)
IEC 60502:1994 Extruded solid dielectric insulated power cables for rated voltages from 1 kV up to 30 kV
I.S. EN 50264-2-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
I.S. 201-13:2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 13: OIL RESISTANT PVC SHEATHED CABLES WITH TWO OR MORE CONDUCTORS
NFC 32 201-15 : 2006 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 15: SINGLE CORE CABLES, INSULATED WITH HALOGEN-FREE THERMOPLASTIC COMPOUND, FOR FIXED WIRING
BS IEC 62613-1 : 2011 PLUGS, SOCKET-OUTLETS AND SHIP COUPLERS FOR HIGH-VOLTAGE SHORE CONNECTION SYSTEMS (HVSC-SYSTEMS) - PART 1: GENERAL REQUIREMENTS
97/207801 DC : DRAFT JUL 1997 IEC 62026-5 - CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS FOR LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5: SMART DISTRIBUTED SYSTEM (SDS)
UNE-EN 16840:2017 Inland navigation vessels - Electrical shore connection, three-phase current 400 V, 50 Hz, at least 250 A
I.S. HD 605:2008 ELECTRIC CABLES - ADDITIONAL TEST METHODS
I.S. EN 61238-1:2003 COMPRESSION AND MECHANICAL CONNECTORS FOR POWER CABLES FOR RATED VOLTAGES UP TO 36 KV (U[M] = 42 KV) - PART 1: TEST METHODS AND REQUIREMENTS
03/318201 DC : DRAFT NOV 2003 IEC 60502-2, ED.2 - POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES FROM 1 KV (UM = 1,2 KV) UP TO 30 KV (UM = 36 KV) - PART 2: CABLES FOR RATED VOLTAGES FROM 6 KV (UM = 7,2 KV) UP TO 30 KV (UM = 36 KV)
BS EN ISO 13628-5:2009 Petroleum and natural gas industries. Design and operation of subsea production systems Subsea umbilicals
BS EN 61138:1998 Cables for portable earthing and short-circuiting equipment
IEC 60227-5:2011 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords)
CEI EN 50525-1 : 2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 1: GENERAL REQUIREMENTS
BS EN 60947-7-1:2009 Low-voltage switchgear and controlgear Ancillary equipment. Terminal blocks for copper conductors
NF EN 50382-1 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
IEC 61892-4:2007 Mobile and fixed offshore units - Electrical installations - Part 4: Cables
08/30188804 DC : 0 BS EN 50525-2-51 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
I.S. HD 22.15:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 15: MULTICORE CABLES INSULATED AND SHEATHED WITH HEAT RESISTANT SILICONE RUBBER
BIS IS/IEC 60079-7 : 2006 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
UNE-EN 50264-2-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
IEC 60092-375:1977 Electrical installations in ships. Shipboard telecommunication cables and radio-frequency cables. General instrumentation, control and communication cables
IEC PAS 80005-3:2014 Utility connections in port - Part 3: Low Voltage Shore Connection (LVSC) Systems - General requirements
NF EN 50264-3-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
NF EN 61009-1 : 2013 AMD 12 2016 RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES
NFC 33 061 : 1999 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - JOINTS FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 500 KV (UM EQUAL TO 525 KV)
I.S. EN 60269-1:2007 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS
I.S. EN 50521:2008 CONNECTORS FOR PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS
I.S. HD 22.13:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE
I.S. EN 60947-1:2007 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES
UNE-EN 50525-2-21:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation
UNE 21144-1-1:2012 Electric cables - Calculation of the current rating - Part 1-1: Current rating equations (100 % load factor) and calculation of losses - General
I.S. HD 22.14:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 14: CORDS FOR APPLICATIONS REQUIRING HIGH FLEXIBILITY
UNE-EN 61230:2011 Live working - Portable equipment for earthing or earthing and short-circuiting
I.S. 201-5:2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 5: FLEXIBLE CABLES (CORDS)
DIN 57472-501 : 1983 TESTING OF CABLES, WIRES AND FLEXIBLE CORDS - CONDUCTOR RESISTANCE
UNE-EN 50548:2012 Junction boxes for photovoltaic modules
CEI 20-56 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV SOMMARIO
UNE-IEC 60092-354:2015 Electrical installations in ships - Part 354: Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV)
CEI EN 50525-2-31 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-31: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH THERMOPLASTIC PVC INSULATION
CEI EN 60352-7 : 2003 SOLDERLESS CONNECTIONS - PART 7: SPRING CLAMP CONNECTIONS - GENERAL REQUIREMENTS, TEST METHODS AND PRACTICAL GUIDANCE
BS EN 60309-1 : 1999 PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 1: GENERAL REQUIREMENTS
I.S. EN 62052-31:2016 ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - PART 31: PRODUCT SAFETY REQUIREMENTS AND TESTS
UNE-EN 50143:2010 Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V
UNE-IEC 60092-352:2015 Electrical installations in ships - Part 352: Choice and installation of electrical cables
NF EN 50264-2-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
I.S. EN 50525-2-41:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-41: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
PREN 50393 : DRAFT 2012 TEST METHODS AND REQUIREMENTS FOR ACCESSORIES FOR USE ON DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1,0 (1,2) KV
NF EN 60947-1 : 2007 AMD 2 2015 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES
NF EN 50548 : 2011 AMD 2 2014 JUNCTION BOXES FOR PHOTOVOLTAIC MODULES
PREN 50525-3-21 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
NFC 32 102-14 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 14: CORDS FOR APPLICATIONS REQUIRING HIGH FLEXIBILITY
PREN 50548 : DRAFT 2009 JUNCTION BOXES FOR PHOTOVOLTAIC MODULES
NFC 33 063 : 1999 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - OUTDOOR TERMINATIONS, WITH PORCELAIN INSULATOR, FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 500 KV (UM EQUAL TO 525 KV)
UNE-EN 61995-1:2010 Devices for the connection of luminaires for household and similar purposes -- Part 1: General requirements
UNE-EN 50525-2-51:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation
IEC 60502-1:2004+AMD1:2009 CSV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV)
IEC 61058-1 REDLINE : 4ED 2016 SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS
CSA C22.2 No. 65 : 2013 WIRE CONNECTORS
I.S. EN 50393:2015 TEST METHODS AND REQUIREMENTS FOR ACCESSORIES FOR USE ON DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1,0 (1,2) KV
I.S. HD 22.12:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 12: HEAT RESISTANT EPR CORDS AND FLEXIBLE CABLES
I.S. EN 50525-2-21:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
I.S. EN 62196-1:2014 PLUGS, SOCKET-OUTLETS, VEHICLE CONNECTORS AND VEHICLE INLETS - CONDUCTIVE CHARGING OF ELECTRIC VEHICLES - PART 1: GENERAL REQUIREMENTS
I.S. EN 50143:2009 CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V
IEC 60287-3-2:2012 Electric cables - Calculation of the current rating - Part 3-2: Sections on operating conditions - Economic optimization of power cable size
ASTM F 1835 : 1997 : R2012 : EDT 1 Standard Guide for Cable Splicing Installations
IEC 60245-1:2003+AMD1:2007 CSV Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 1: General requirements
I.S. EN 50085-1:2005 CABLE TRUNKING SYSTEMS AND CABLE DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS
EN 61918:2013/AC:2014 INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES (IEC 61918:2013, MODIFIED)
UNE-EN 61439-1:2012 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
02/203840 DC : DRAFT MAY 2002 IEC 60204-1/ED.5.0 - SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS
IEC 60204-32:2008 Safety of machinery - Electrical equipment of machines - Part 32: Requirements for hoisting machines
BS EN 45510-2-9:2008 Guide for procurement of power station equipment Electrical equipment. Cabling systems
BS EN 60204-1 : 2006 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS
06/30148719 DC : DRAFT APR 2006 IEC 62026-2 ED.2 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONTROLLER-DEVICE INTERFACES (C DIS) - PART 2: ACTUATOR SENSOR INTERFACE (AS-I)
BS EN 60204-32:2008 Safety of machinery. Electrical equipment of machines Requirements for hoisting machines
IEC 62852:2014 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
BS EN 61439-1:2011 Low-voltage switchgear and controlgear assemblies General rules
EN 50548 : 2011 AMD 2 2014 JUNCTION BOXES FOR PHOTOVOLTAIC MODULES
OVE/ONORM E 8684-1 : 2010 PLUGS AND SOCKET-OUTLETS FOR HOUSEHOLD AND SIMILAR PURPOSES - PART 1: GENERAL REQUIREMENTS
HD 22.15 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 15: MULTICORE CABLES INSULATED AND SHEATHED WITH HEAT RESISTANT SILICONE RUBBER
EN 60309-1:1999/A1:2007/AC:2014 PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 1: GENERAL REQUIREMENTS (IEC 60309-1:1999/A2:2012)
EN 50521:2008/A1:2012 CONNECTORS FOR PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS
EN 50525-2-12:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-12: Cables for general applications - Cables with thermoplastic PVC insulation for extensible leads
EN 61984:2009 Connectors - Safety requirements and tests
CLC/TR 50480:2011 Determination of cross-sectional area of conductors and selection of protective devices
EN 60998-2-2:2004 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units
EN 60998-1:2004 Connecting devices for low-voltage circuits for household and similar purposes - Part 1: General requirements
HD 22.10 S2:2007 Cables of rated voltages up to and including 450/750 V and having cross-linked insulation - Part 10: EPR insulated and polyurethane sheathed flexible cables
EN 50525-2-42:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-42: Cables for general applications - Single core non-sheathed cables with crosslinked EVA insulation
EN 60947-7-1:2009 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 7-1: ANCILLARY EQUIPMENT - TERMINAL BLOCKS FOR COPPER CONDUCTORS
HD 22-9 : 200S3 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE
EN 50143:2009 Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V
IEC 60364-7-712:2017 RLV Low voltage electrical installations - Part 7-712: Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems
EN 50264-2-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
EN 60999-1:2000 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included)
EN 50264-3-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
EN 60204-32:2008 Safety of machinery - Electrical equipment of machines - Part 32: Requirements for hoisting machines
HD 384.5.523 : 200S2 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SECTION 523: CURRENT-CARRYING CAPACITIES IN WIRING SYSTEMS
EN 50382-2:2008/A1:2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
EN 50343 : 2014 AMD 1 2017 RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING
EN 50214:2006/corrigendum Dec. 2007 FLAT POLYVINYL CHLORIDE SHEATHED FLEXIBLE CABLES
EN 50525-2-82:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains
EN 50525-3-21:2011/AC:2013 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
EN 61076-3-120 : 2016 Connectors for electronic equipment - Product requirements - Part 3-120: Rectangular connectors - Detail specification for rewirable power connectors with snap locking for rated voltage of 250 V d.c. and rated current of 30 A
EN 50288-7:2005 Multi-element metallic cables used in analogue and digital communication and control - Part 7: Sectional specification for instrumentation and control cables
EN 61238-1:2003 Compression and mechanical connectors for power cables for rated voltages up to 36 kV (Um = 42 kV) - Part 1: Test methods and requirements
EN 50525-3-41:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
EN 60999-2:2003 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm² up to 300 mm² (included)
EN 50525-2-11:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation
EN 50618:2014 Electric cables for photovoltaic systems
EN 50525-2-21:2011/AC:2013 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
UNE-HD 620.1:2010 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 1: General requirements.
CEI EN IEC 60352-6:2023 Solderless connections Part 6: Insulation piercing connections - General requirements, test methods and practical guidance
BS 88-1(2007) : 2007 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS
UNE-HD 60364-5-52:2014 Low-voltage electrical installations -- Part 5-52: Selection and erection of electrical equipment - Wiring systems

AS/NZS IEC 60227.5:2019 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V Flexible cables (cords)
AS/NZS IEC 60245.4:2020 Rubber insulated cables - Rated voltages up to and including 450/750 V Cords and flexible cables
AS/NZS 60092.354:2020 Electrical installations in ships Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) (IEC 60092-354:2014 (ED.3.0) MOD)
AS/NZS IEC 60092.353:2020 Electrical installations in ships Power cables for rated voltages 1 kV and 3 kV

View more information
US$133.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.