Electric and optical fibre cables - Test methods for non-metallic materials - Part 513: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Wrapping test after conditioning
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French, Spanish, Castilian

Published date

03-13-2012

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Test method
5 Test report
Bibliography

IEC 60811-513:2012 gives procedures for a wrapping test after conditioning at elevated temperature. This test method applies specifically to polyethylene and polypropylene insulation. This test is intended for samples from filled cables of polyolefin insulation having a wall thickness of less than or equal to 0,8 mm. IEC 60811-513:2012 cancels and replaces Clause 9 of IEC 60811-4-2:2004, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.

This publication is to be read in conjunction with IEC 60811-100:2012.

Committee
TC 20
DevelopmentNote
To be read in conjunction with IEC 60811-100. (03/2012) Supersedes IEC 60811-4-2. (05/2012) Stability Date: 2020. (11/2017)
DocumentType
Standard
Pages
16
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

13/30281393 DC : 0 BS EN 50290-2-23 - COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - PE INSULATION
I.S. EN 50290-2-23:2013 COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES
UNE-EN 50290-2-23:2014 Communication cables - Part 2-23: Common design rules and construction - Polyethylene insulation for multi-pair cables used in access telecommunication networks: Outdoor cables
BS EN 50290-2-23:2013 Communication cables Common design rules and construction. Polyethylene insulation for multi-pair cables used in access telecommunication networks: Outdoor cables
CEI EN 50290-2-23 : 2014 COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES
PREN 50290-2-23 : DRAFT 2013 COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - PE INSULATION
EN 50290-2-23:2013 COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES

IEC 60811-601:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 601: Physical tests - Measurement of the drop point of filling compounds
IEC 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General

View more information
US$23.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.