• There are no items in your cart

IEC 61391-1:2006+AMD1:2017 CSV

Current
Current

The latest, up-to-date edition.

Ultrasonics - Pulse-echo scanners - Part 1: Techniques for calibrating spatial measurement systems and measurement of point-spread function response
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English, English - French

Published date

07-10-2017

IEC 61391-1:2006+A1:2017 describes methods of calibrating the spatial measurement facilities and point-spread function of ultrasonic imaging equipment in the ultrasonic frequency range 0,5 MHz to 15 MHz. This standard is relevant for ultrasonic scanners based on the pulse echo principle of the types listed below: - mechanical sector scanners; - electronic phased-array sector scanners; - electronic linear-array scanners; - electronic curved-array sector scanners; - water bath scanners based on any of the above four scanning mechanisms; - 3D-volume reconstruction systems. This consolidated version consists of the first edition (2006) and its amendment 1 (2017). Therefore, no need to order amendment in addition to this publication.

Committee
TC 87
DevelopmentNote
Stability Date: 2019. (07/2017)
DocumentType
Standard
Pages
132
PublisherName
International Electrotechnical Committee
Status
Current

PD IEC/TS 62736:2016 Ultrasonics. Pulse-echo scanners. Simple methods for periodic testing to verify stability of an imaging system’s elementary performance
DD IEC/TS 62558:2011 Ultrasonics. Real-time pulse-echo scanners. Phantom with cylindrical, artificial cysts in tissue-mimicking material and method for evaluation and periodic testing of 3D-distributions of void-detectability ratio (VDR)
I.S. EN 61391-2:2010 ULTRASONICS - PULSE-ECHO SCANNERS - PART 2: MEASUREMENT OF MAXIMUM DEPTH OF PENETRATION AND LOCAL DYNAMIC RANGE
NF EN 61391-2 : 2011 ULTRASONICS - PULSE-ECHO SCANNERS - PART 2: MEASUREMENT OF MAXIMUM DEPTH OF PENETRATION AND LOCAL DYNAMIC RANGE
EN 61391-2:2010 Ultrasonics - Pulse-echo scanners - Part 2: Measurement of maximum depth of penetration and local dynamic range
CEI EN 61391-2 : 2011 ULTRASONICS - PULSE-ECHO SCANNERS - PART 2: MEASUREMENT OF MAXIMUM DEPTH OF PENETRATION AND LOCAL DYNAMIC RANGE
IEC TS 62558:2011 Ultrasonics - Real-time pulse-echo scanners - Phantom with cylindrical, artificial cysts in tissue-mimicking material and method for evaluation and periodic testing of 3D-distributions of void-detectability ratio (VDR)
IEC TS 62791:2015 Ultrasonics - Pulse-echo scanners - Low-echo sphere phantoms and method for performance testing of gray-scale medical ultrasound scanners applicable to a broad range of transducer types
07/30161032 DC : 0 BS EN 61391-2 - ULTRASONICS - PULSE ECHO SCANNERS - PART 2: TECHNIQUES FOR MEASUREMENT OF MAXIMUM DEPTH OF VISUALIZATION AND THE DISPLAYED DYNAMIC RANGE
PD IEC/TS 62791:2015 Ultrasonics. Pulse-echo scanners. Low-echo sphere phantoms and method for performance testing of gray-scale medical ultrasound scanners applicable to a broad range of transducer types
08/30177593 DC : DRAFT FEB 2008 BS EN 62558 - ULTRASONIC - REAL-TIME PULSE-ECHO SCANNERS - PHANTOM AND METHOD FOR AUTOMATED EVALUATION AND PERIODIC TESTING OF 3-D DISTRIBUTIONS OF SIGNAL-TO-NOISE RATIO USING VOIDS
IEC TS 62736:2016 Ultrasonics - Pulse-echo scanners - Simple methods for periodic testing to verify stability of an imaging system's elementary performance
IEC 61391-2:2010 Ultrasonics - Pulse-echo scanners - Part 2: Measurement of maximum depth of penetration and local dynamic range
BS EN 61391-2:2010 Ultrasonics. Pulse-echo scanners Measurement of maximum depth of penetration and local dynamic range
14/30250927 DC : 0 BS IEC 62736 - ULTRASONICS - PULSE-ECHO SCANNERS - QUALITY CONTROL OF DIAGNOSTIC MEDICAL ULTRASOUND SYSTEMS - SIMPLE METHODS FOR PERIODIC TESTING TO VERIFY STABILITY OF AN IMAGING SYSTEM'S ELEMENTARY PERFORMANCE

IEC 62127-1:2007+AMD1:2013 CSV Ultrasonics - Hydrophones - Part 1: Measurement and characterizationof medical ultrasonic fields up to 40 MHz
ISO 5725-1:1994 Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions
IEC 60050-802:2011 International Electrotechnical Vocabulary (IEV) - Part 802: Ultrasonics
IEC 61828:2001 Ultrasonics - Focusing transducers - Definitions and measurement methods for the transmitted fields
IEC TR 60854:1986 Methods of measuring the performance of ultrasonic pulse-echo diagnostic equipment
IEC TR 62781:2012 Ultrasonics - Conditioning of water for ultrasonic measurements
IEC 60050-801:1994 International Electrotechnical Vocabulary (IEV) - Part 801: Acoustics and electroacoustics
IEC 62563-1:2009+AMD1:2016 CSV Medical electrical equipment - Medical image display systems - Part1: Evaluation methods
IEC 61391-2:2010 Ultrasonics - Pulse-echo scanners - Part 2: Measurement of maximum depth of penetration and local dynamic range
IEC TS 62558:2011 Ultrasonics - Real-time pulse-echo scanners - Phantom with cylindrical, artificial cysts in tissue-mimicking material and method for evaluation and periodic testing of 3D-distributions of void-detectability ratio (VDR)
IEC TS 62791:2015 Ultrasonics - Pulse-echo scanners - Low-echo sphere phantoms and method for performance testing of gray-scale medical ultrasound scanners applicable to a broad range of transducer types
IEC 61157:2007+AMD1:2013 CSV Standard means for the reporting of the acoustic output of medicaldiagnostic ultrasonic equipment
IEC TS 62736:2016 Ultrasonics - Pulse-echo scanners - Simple methods for periodic testing to verify stability of an imaging system's elementary performance
IEC 61685:2001 Ultrasonics - Flow measurement systems - Flow test object

View more information
US$615.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.