IEC 61504:2017
Current
The latest, up-to-date edition.
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
05-11-2017
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Design requirements
5 General test procedures
6 Documentation
Annex A (informative) - Cross-references for centralized
system for radiation monitoring standards
Bibliography
IEC 61504:2017 supplements IEC 61559-1 and includes radiation monitoring functions important to safety that are outside the scope of IEC 61559-1. It applies to centralized systems having a direct role in the achievement or maintenance of radiation protection in nuclear facilities. These systems perform functions such as:
- radiation protection of plant discharge; interlock of control functions to prevent or to mitigate accidental release of radioactive material;
- radiation and environmental monitoring functions to support monitoring of and response to accidents;
- provide information to process control or safety systems for use in control or interlock functions. This new edition includes the following significant technical changes with respect to the previous edition:
- it supplements IEC 61559-1 and integrates IEC 61559-2;
- it describes integration of functions including equipment covered by other IEC standards.
DevelopmentNote |
Supersedes IEC 61559-2. To be read in conjunction with IEC 61559-1. Stability Date: 2019. (05/2017)
|
DocumentType |
Standard
|
Pages |
59
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
VDE 0491-16:2022-05 | Identical |
DIN IEC 61504:2022-05 | Identical |
BS IEC 61504:2017 | Identical |
NEN IEC 61504 : 2001 | Identical |
IEC 62705:2014 | Nuclear power plants - Instrumentation and control important to safety - Radiation monitoring systems (RMS): Characteristics and lifecycle |
BS IEC 60768:2009 | Nuclear power plants. Instrumentation important to safety. Equipment for continuous in-line or on-line monitoring of radioactivity in process streams for normal and incident conditions |
BS IEC 62705:2014 | Nuclear power plants. Instrumentation and control important to safety. Radiation monitoring systems (RMS): Characteristics and lifecycle |
07/30172925 DC : 0 | BS IEC 60951-1 - NUCLEAR POWER PLANTS - INSTRUMENTATION IMPORTANT TO SAFETY - RADIATION MONITORING SYSTEM FOR ACCIDENT AND POST ACCIDENT CONDITIONS - PART 1: GENERAL REQUIREMENTS |
IEC 60951-1:2009 | Nuclear power plants - Instrumentation important to safety - Radiation monitoring for accident and post-accident conditions - Part 1: General requirements |
IEC 60532:2010 | Radiation protection instrumentation - Installed dose rate meters, warning assemblies and monitors - X and gamma radiation of energy between 50 keV and 7 MeV |
BS IEC 60951-1:2009 | Nuclear power plants. Instrumentation important to safety. Radiation monitoring for accident and post-accident conditions General requirements |
BS IEC 61559-1:2009 | Radiation protection instrumentation in nuclear facilities. Centralized systems for continuous monitoring of radiation and/or levels of radioactivity General requirements |
IEC 60768:2009 | Nuclear power plants - Instrumentation important to safety - Equipment for continuous in-line or on-line monitoring of radioactivity in process streams for normal and incident conditions |
IEC 61559-1:2009 | Radiation protection instrumentation in nuclear facilities - Centralized systems for continuous monitoring of radiation and/or levels of radioactivity - Part 1: General requirements |
13/30249610 DC : 0 | BS EN 62705 ED 1.0 - NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - RADIATION MONITORING SYSTEMS (RMS) CHARACTERISTICS AND TEST METHODS |
BS IEC 60532:2010 | Radiation protection instrumentation. Installed dose rate meters, warning assemblies and monitors. X and gamma radiation of energy between 50 keV and 7 MeV |
IEC 60761-5:2002 | Equipment for continuous monitoring of radioactivity in gaseous effluents - Part 5: Specific requirements for tritium monitors |
IEC 60951-2:2009 | Nuclear power plants - Instrumentation important to safety - Radiation monitoring for accident and post-accident conditions - Part 2: Equipment for continuous off-line monitoring of radioactivity in gaseous effluents and ventilation air |
IEC 61559-2:2002 | Radiation in nuclear facilities - Centralized systems for continuous monitoring of radiation and/or levels of radioactivity - Part 2: Requirements for discharge, environmental, accident, or post-accident monitoring functions |
IEC 61226:2009 | Nuclear power plants - Instrumentation and control important to safety - Classification of instrumentation and control functions |
IEC 61500:2009 | Nuclear power plants - Instrumentation and control important to safety - Data communication in systems performing category A functions |
IEC 60532:2010 | Radiation protection instrumentation - Installed dose rate meters, warning assemblies and monitors - X and gamma radiation of energy between 50 keV and 7 MeV |
IEC 62138:2004 | Nuclear power plants - Instrumentation and control important for safety - Software aspects for computer-based systems performing category B or C functions |
IEC 62705:2014 | Nuclear power plants - Instrumentation and control important to safety - Radiation monitoring systems (RMS): Characteristics and lifecycle |
IEC 61772:2009 | Nuclear power plants - Control rooms - Application of visual display units (VDUs) |
IEC 61559-1:2009 | Radiation protection instrumentation in nuclear facilities - Centralized systems for continuous monitoring of radiation and/or levels of radioactivity - Part 1: General requirements |
IEC 61250:1994 | Nuclear reactors - Instrumentation and control systems important for safety - Detection of leakage in coolant systems |
IEC 62003:2009 | Nuclear power plants - Instrumentation and control important to safety - Requirements for electromagnetic compatibility testing |
IEC 62303:2008 | Radiation protection instrumentation - Equipment for monitoring airborne tritium |
IEC 60761-2:2002 | Equipment for continuous monitoring of radioactivity in gaseous effluents - Part 2: Specific requirements for radioactive aerosol monitors including transuranic aerosols |
IEC 60761-3:2002 | Equipment for continuous monitoring of radioactivity in gaseous effluents - Part 3: Specific requirements for radioactive noble gas monitors |
IEC 60761-4:2002 | Equipment for continuous monitoring of radioactivity in gaseous effluents - Part 4: Specific requirements for radioactive iodine monitors |
IEC 60987:2007+AMD1:2013 CSV | Nuclear power plants - Instrumentation and control important to safety - Hardware design requirements for computer-based systems |
IEC 60951-1:2009 | Nuclear power plants - Instrumentation important to safety - Radiation monitoring for accident and post-accident conditions - Part 1: General requirements |
IEC 61497:1998 | Nuclear power plants - Electrical interlocks for functions important to safety - Recommendations for design and implementation |
IEC 61031:1990 | Design, location and application criteria for installed area gamma radiation dose rate monitoring equipment for use in nuclear power plants during normal operation and anticipated operational occurrences |
IEC 60910:1988 | Containment monitoring instrumentation for early detection of developing deviations from normal operation in light water reactors |
IEC 62302:2007 | Radiation protection instrumentation - Equipment for sampling and monitoring radioactive noble gases |
IEC 60951-3:2009 | Nuclear power plants - Instrumentation important to safety - Radiation monitoring for accident and post-accident conditions - Part 3: Equipment for continuous high range area gamma monitoring |
IEC 60861:2006 | Equipment for monitoring of radionuclides in liquid effluents and surface waters |
IEC 61771:1995 | Nuclear power plants - Main control-room - Verification and validation of design |
IEC 60951-4:2009 | Nuclear power plants - Instrumentation important to safety - Radiation monitoring for accident and post-accident conditions - Part 4: Equipment for continuous in-line or on-line monitoring of radioactivity in process streams |
IEC 60960:1988 | Functional design criteria for a safety parameter display system for nuclear power stations |
IEC 60880:2006 | Nuclear power plants - Instrumentation and control systems important to safety - Software aspects for computer-based systems performing category A functions |
IEC 60761-1:2002 | Equipment for continuous monitoring of radioactivity in gaseous effluents - Part 1: General requirements |
IEC 61513:2011 | Nuclear power plants - Instrumentation and control important to safety - General requirements for systems |
IEC 60768:2009 | Nuclear power plants - Instrumentation important to safety - Equipment for continuous in-line or on-line monitoring of radioactivity in process streams for normal and incident conditions |
IEC/IEEE 60780-323:2016 | Nuclear facilities - Electrical equipment important to safety - Qualification |
IEC 62566:2012 | Nuclear power plants - Instrumentation and control important to safety - Development of HDL-programmed integrated circuits for systems performing category A functions |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.