FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 General
  4.1 Measurement philosophy
  4.2 Principle set-up
  4.3 Workbench concept
5 Test conditions
6 Test equipment
7 Test set-up
  7.1 Shielding and ambient fields
  7.2 Workbench set-up
  7.3 Connections to the PCB
  7.4 Common-mode points
      7.4.1 Comparison testing
      7.4.2 Definitive application
  7.5 Emission limits
  7.6 Workbench - Practical implementation
  7.7 Test PCB
8 Test procedure
9 Test report
  9.1 Emission criteria
  9.2 Emission levels
Annex A (normative) - Detail specification of Workbench
                        Faraday Cage (WBFC)
Annex B (informative) - Common-mode impedances
Annex C (informative) - Derivation of limits
Annex D (informative) - Use of the Workbench
Bibliography
Figures
Tables

Describes a method to measure the conducted electromagnetic emission of integrated circuits either applied on a standardised test-board or on a final printed circuit board (PCB).Has a high repeatability and a good relationship to the measured RF emission of final applications with the integrated circuits used.

Committee
TC 47/SC 47A
DevelopmentNote
To be read in conjunction with IEC 61967-1. (02/2003) Stability Date: 2019. (09/2017)
DocumentType
Standard
Pages
47
PublisherName
International Electrotechnical Committee
Status
Current

Standards Relationship
SN EN 61967-5 : 2003 Identical
CEI EN 61967-5 : 2004 Identical
DIN EN 61967-5:2003-10 Identical
NF EN 61967-5 : 2003 Identical
PN EN 61967-5 : 2004 Identical
EN 61967-5:2003 Identical
NEN EN IEC 61967-5 : 2003 Identical
BS EN 61967-5:2003 Identical
I.S. EN 61967-5:2003 Identical
UNE-EN 61967-5:2003 Identical

PD IEC/TR 61967-4-1:2005 Integrated circuits. Measurement of electromagnetic emissions, 150 kHz to 1 GHz Measurement of conducted emissions. 1 Ohm/150 Ohm direct coupling method. Application guidance to IEC 61967-4
06/30152634 DC : DRAFT JULY 2006
CEI EN 61967-1 : 2002 INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC EMISSIONS, 150 KHZ TO 1 GHZ - PART 1: GENERAL CONDITIONS AND DEFINITIONS
I.S. EN 62132-5:2006 INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC IMMUNITY, 150 KHZ TO 1 GHZ - PART 5: WORKBENCH FARADAY CAGE METHOD
EN IEC 62969-1:2018 Semiconductor devices - Semiconductor interface for automotive vehicles - Part 1: General requirements of power interface for automotive vehicle sensors
IEC 62969-1:2017 Semiconductor devices - Semiconductor interface for automotive vehicles - Part 1: General requirements of power interface for automotive vehicle sensors
IEC 62132-5:2005 Integrated circuits - Measurement of electromagnetic immunity, 150 kHz to 1 GHz - Part 5: Workbench Faraday cage method
BS EN 62132-5:2006 Integrated circuits. Measurement of electromagnetic immunity, 150 kHz to 1 GHz Workbench Faraday cage method
07/30163156 DC : 0 BS EN 62433-2 - MODELS OF INTEGRATED CIRCUITS FOR EMI BEHAVIOURAL SIMULATION - ICEM-CE, ICEM CONDUCTED EMISSION MODEL
IEC 61967-1:2002 Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 1: General conditions and definitions
16/30336986 DC : 0 BS EN 62969-1 - SEMICONDUCTOR DEVICES - SEMICONDUCTOR INTERFACE FOR AUTOMOTIVE VEHICLES - PART 1: GENERAL REQUIREMENTS OF POWER INTERFACE FOR AUTOMOTIVE VEHICLE SENSORS
01/209170 DC : DRAFT DEC 2001 IEC 62132-5 ED.1 - INTEGRATED CIRCUITS, MEASUREMENT OF ELECTROMAGNETIC IMMUNITY - PART 5: MEASUREMENT OF CONDUCTED IMMUNITY - WORKBENCH FARADAY CAGE METHOD
IEC TR 61967-4-1:2005 Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 4-1: Measurement of conducted emissions - 1 Ω/150 Ω direct coupling method - Application guidance to IEC 61967-4
EN 62132-5:2006 Integrated circuits - Measurement of electromagnetic immunity, 150 kHz to 1 GHz - Part 5: Workbench Faraday cage method

IEC 60050-131:2002 International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory
MIL-STD-285 Base Document:1956 ATTENUATION MEASUREMENTS FOR ENCLOSURES, ELECTROMAGNETIC SHIELDING, FOR ELECTRONIC TEST PURPOSES, METHOD OF
IEC 61967-1:2002 Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 1: General conditions and definitions
IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61967-4:2002+AMD1:2006 CSV Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 4: Measurement of conducted emissions - 1 Ω/150 Ω direct coupling method
CISPR 16-2:2003 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2: Methods of measurement of disturbances and immunity
IEC 61967-6:2002+AMD1:2008 CSV Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 6: Measurement of conducted emissions - Magnetic probe method
CISPR 16-1:1999+AMD1:2002 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus

View more information
US$174.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.