• There are no items in your cart

IEC 88528-11:2004

Current
Current

The latest, up-to-date edition.

Reciprocating internal combustion engine driven alternating current generating sets - Part 11: Rotary uninterruptible power systems - Performance requirements and test methods
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

03-23-2004

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
   3.1 General
   3.2 Performance of systems and components
   3.3 Specified values
   3.4 Input values
   3.5 Output values
4 Symbols and abbreviations
5 Selection criteria
6 General description
   6.1 Rotary UPS
   6.2 Types of rotary UPS
        6.2.1 Series connected rotary UPS
        6.2.2 Line interactive rotary UPS
   6.3 Parallel operation of a rotary UPS installation
        6.3.1 General
        6.3.2 Parallel operation
        6.3.3 Redundant operation
   6.4 Power system changeover with rotary UPS
        installations (bypass)
   6.5 Enclosure protection
7 Modes of operation
   7.1 Power conditioning mode
   7.2 Independent mode
   7.3 Bypass mode
   7.4 Off mode
   7.5 Transitions
        7.5.1 Transition 1, starting the system with
               mains voltage present
        7.5.2 Transition 2, start-up without mains
               voltage (black start)
        7.5.3 Transition 3, disconnect from grid
        7.5.4 Transition 4, connect to grid
        7.5.5 Transition 6, transfer
        7.5.6 Transition 7, 8, retransfer
8 Service conditions
   8.1 Normal service conditions
   8.2 Operation at extended ambient
        8.2.1 Ambient service temperature
        8.2.2 Ambient storage and transportation
               conditions
   8.3 Engines
   8.4 Rotating electrical machines
   8.5 Control logic
9 Electrical service conditions and performance
   9.1 General - all rotary UPS
   9.2 Performance
10 Manufacturer technical declarations
   10.1 General
   10.2 Purchaser specification guidelines
        10.2.1 Type of rotary UPS, additional features,
               and system requirements
        10.2.2 Rotary UPS input
        10.2.3 Load to be supplied from a rotary UPS
        10.2.4 Rotary UPS output
        10.2.5 Battery (where applicable)
        10.2.6 General application requirements and
               special service conditions
        10.2.7 Multi-module system configurations
        10.2.8 Electromagnetic compatibility
11 Testing
   11.1 Static output voltage and frequency deviations
   11.2 Dynamic output voltage and frequency deviations
   11.3 Input current characteristics
   11.4 Measurement of filter properties
        11.4.1 From mains to output
        11.4.2 From output to mains
   11.5 System performance
        11.5.1 Efficiency
        11.5.2 Stored energy times
        11.5.3 Multi-module rotary UPS performance
   11.6 Black start test
   11.7 Environmental tests
   11.8 Audible noise
   11.9 Testing
12 Maintenance and product marking
   12.1 Nameplate markings
   12.2 Label requirements
   12.3 Name plate marker
   12.4 Decals - labelling
        12.4.1 Safety instructions and documentation
   12.5 Maintenance
Annex A (informative) Typical energy storage devices
Annex B (normative) Reference non-linear load - Single-phase
Annex C (normative) Reference non-linear load - Three-phase
Annex D (normative) Input mains failure - Test method
Annex E (informative) Types of uninterruptible power
        systems (UPS) configurations

Specifies criteria, including performance and test methods, for rotary uninterruptible power systems arising out of a combination of mechanical and electrical rotating machines. Applies to power supplies primarily designed for supplying uninterrupted a.c. power to the consumer.

DevelopmentNote
Stability date: 2018. (09/2017)
DocumentType
Standard
Pages
47
PublisherName
International Electrotechnical Committee
Status
Current

BS EN 50600-2-2:2014 Information technology. Data centre facilities and infrastructures Power distribution
I.S. EN 50600-2-2:2014 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-2: POWER DISTRIBUTION
INCITS/ISO TS 19159-1 : 2015 GEOGRAPHIC INFORMATION - CALIBRATION AND VALIDATION OF REMOTE SENSING IMAGERY SENSORS AND DATA - PART 1: OPTICAL SENSORS
EN 50600-2-2:2014 Information technology - Data centre facilities and infrastructures - Part 2-2: Power distribution
ISO/TS 19159-1:2014 Geographic information Calibration and validation of remote sensing imagery sensors and data Part 1: Optical sensors

IEC 60034-22:2009 Rotating electrical machines - Part 22: AC generators for reciprocating internal combustion (RIC) engine driven generating sets
ISO 8528-6:2005 Reciprocating internal combustion engine driven alternating current generating sets — Part 6: Test methods
ISO 8178-1:2017 Reciprocating internal combustion engines Exhaust emission measurement Part 1: Test-bed measurement systems of gaseous and particulate emissions
ISO 8528-10:1998 Reciprocating internal combustion engine driven alternating current generating sets — Part 10: Measurement of airborne noise by the enveloping surface method
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
ISO 8528-9:2017 Reciprocating internal combustion engine driven alternating current generating sets — Part 9: Measurement and evaluation of mechanical vibrations
IEC 60034-1:2017 Rotating electrical machines - Part 1: Rating and performance
ISO 8528-1:2005 Reciprocating internal combustion engine driven alternating current generating sets Part 1: Application, ratings and performance
ISO 3046-1:2002 Reciprocating internal combustion engines Performance Part 1: Declarations of power, fuel and lubricating oil consumptions, and test methods Additional requirements for engines for general use
ISO 7000:2014 Graphical symbols for use on equipment Registered symbols

View more information
US$313.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.