• There are no items in your cart

IEC TR 60909-4:2000

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Short-circuit currents in three-phase a.c. systems - Part 4: Examples for the calculation of short-circuit currents
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

12-31-2021

Language(s)

English - French, Spanish, Castilian

Published date

07-21-2000

FOREWORD
1 General
      1.1 Scope and object
      1.2 Reference documents
      1.3 Definitions, symbols and indices, and equations
2 Positive-sequence, negative-sequence and zero-sequence
      impedance's of electrical equipment
      2.1 Overhead lines, cables and short-circuit
             limiting reactors
      2.2 Transformers
      2.3 Generators and power-station units
3 Calculation of short-circuit currents in a low-voltage
      system Un = 400 V
      3.1 Problem
      3.2 Determination of the positive-sequence
             impedance's
             3.2.1 Network feeder
             3.2.2 Transformers
             3.2.3 Lines (cables and overhead lines)
      3.3 Determination of the zero-sequence impedance's
             3.3.1 Transformers
             3.3.2 Lines (cables and overhead lines)
      3.4 Calculation of Ik and ip for three-phase short
             circuits
             3.4.1 Short-circuit location F1
             3.4.2 Short-circuit location F2
             3.4.3 Short-circuit location F3
      3.5 Calculation of Ikl and ip1 for line-to-earth
             short circuits
             3.5.1 Short-circuit location F1
             3.5.2 Short-circuit location F2
             3.5.3 Short-circuit location F3
      3.6 Collection of results
4 Calculation of three-phase short-circuit currents in
      a medium-voltage system - influence of motors
      4.1 Problem
      4.2 Complex calculation with absolute quantities
      4.3 Calculation with short-circuit reactances of
             electrical equipment
      4.4 Calculation with per-unit quantities
      4.5 Calculation with the superposition method
5 Calculation of three-phase short-circuit currents for
      a power station unit and the auxiliary network
      5.1 Problem
      5.2 Short-circuit impedance's of electrical
             equipment
             5.2.1 Network feeder
             5.2.2 Power-station unit
             5.2.3 Auxiliary transformers
             5.2.4 Low-voltage transformers 2,5 MVA and
                      1,6 MVA
             5.2.5 Asynchronous motors
      5.3 Calculation of short-circuit currents
             5.3.1 Short-circuit location F1
             5.3.2 Short-circuit location F2
             5.3.3 Short-circuit location F3
             5.3.4 Short-circuit location F4
             5.3.5 Short-circuit location F5
6 Test network for the calculation of short-circuit
      currents with digital programs in accordance with
      IEC 60909-0
      6.1 General
      6.2 High-voltage test network 380 kV/110 kV/30 kV
             6.2.1 Network topology and data
             6.2.2 Short-circuit impedance's of electrical
                      equipment
      6.3 Results
             6.3.1 Three-phase short-circuit currents
             6.3.2 Line-to-earth short-circuit currents

Intended to give help for the application of IEC 60909-0 for the calculation of short-circuit currents in 50 Hz or 60 Hz three-phase a.c. systems. It does not include additional requirements but does give support for the modelling of electrical equipment in the positive-sequence, the negative-sequence and the zero-sequence system and the practical execution of calculations in a low-voltage system, a medium-voltage system with asynchronous motors and a power-station unit with its auxiliary network feeding a large number of medium-voltage asynchronous motors and low-voltage motor groups.

Committee
TC 73
DevelopmentNote
Stability Date: 2017. (09/2017)
DocumentType
Technical Report
Pages
131
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
SANS 60909-4 : 1ED 2010(R2015) Identical
NEN NPR IEC/TR 60909-4 : 2000 Identical
VDE 0102 Beiblatt 1:2002 Identical
UNE 21239-4:2002 IN Identical

IEC TR 60909-2:2008 Short-circuit currents in three-phase a.c. systems - Part 2: Data of electrical equipment for short-circuit current calculations
EN 60909-0:2016 Short-circuit currents in three-phase a.c. systems - Part 0: Calculation of currents
12/30270636 DC : 0 BS EN 60909-0 - SHORT-CIRCUIT CURRENTS IN THREE-PHASE A.C. SYSTEMS - PART 0: CALCULATION OF CURRENTS
UNE-IEC/TR 60909-2:2010 IN Short-circuit currents in three-phase a.c. systems - Part 2: Data of electrical equipment for short-circuit current calculations
BS EN 60909-0:2016 Short-circuit currents in three-phase a.c. systems Calculation of currents
I.S. EN 60909-0:2016 SHORT-CIRCUIT CURRENTS IN THREE-PHASE A.C. SYSTEMS - PART 0: CALCULATION OF CURRENTS

IEC 60038:2009 IEC standard voltages
IEC TR 60909-1:2002 Short-circuit currents in three-phase a.c. systems - Part 1: Factors for the calculation of short-circuit currents according to IEC 60909-0

View more information
US$400.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.