CSA C22.4 PACKAGE : 2009
|
CONSISTS OF C22.4 NO. 1-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE AND C22.4 NO. 2-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE - SAFETY MANAGEMENT SYSTEM REQUIREMENTS |
BS ISO/IEC IEEE 80005-1 : 2012
|
UTILITY CONNECTIONS IN PORT - PART 1: HIGH VOLTAGE SHORE CONNECTION (HVSC) SYSTEMS - GENERAL REQUIREMENTS |
IEEE 399 : 1997
|
INDUSTRIAL AND COMMERCIAL POWER SYSTEMS ANALYSIS |
BS PD IEC/PAS 80005-3 : 2014
|
UTILITY CONNECTIONS IN PORT - PART 3: LOW VOLTAGE SHORE CONNECTION (LVSC) SYSTEMS - GENERAL REQUIREMENTS |
IEEE C62.23 : 1995
|
APPLICATION GUIDE FOR SURGE PROTECTION OF ELECTRIC GENERATING PLANTS |
16/30328492 DC : 0
|
BS IEC 80005-3 ED 1.0 - UTILITY CONNECTIONS IN PORT - PART 3: LOW VOLTAGE SHORE CONNECTION (LVSC) SYSTEMS - GENERAL REQUIREMENTS |
NEMA ICS 18 : 2001(R2007)
|
INDUSTRIAL CONTROL AND SYSTEMS: MOTOR CONTROL CENTERS |
BS PD IEC TR 62655 : 2013
|
TUTORIAL AND APPLICATION GUIDE FOR HIGH-VOLTAGE FUSES |
IEEE DRAFT 463 : D6 2006
|
ELECTRICAL SAFETY PRACTICES IN ELECTROLYTIC CELL LINE WORKING ZONES |
IEEE DRAFT 551 : D5 2005
|
CALCULATING AC SHORT-CIRCUIT CURRENTS IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS |
CSA C22.4 No. 1 : 2009(R2018)
|
OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE |
IEEE 1036 : 2010
|
GUIDE FOR APPLICATION OF SHUNT POWER CAPACITORS |
IEEE C37.27 : 2008
|
LOW-VOLTAGE AC (635 V AND BELOW) POWER CIRCUIT BREAKERS APPLIED WITH SEPARATELY-MOUNTED CURRENT-LIMITING FUSES |
IEEE DRAFT 277 : D1 2007
|
CEMENT PLANT POWER DISTRIBUTION |
IEEE DRAFT 741 : D1 2006
|
CRITERIA FOR THE PROTECTION OF CLASS 1E POWER SYSTEMS AND EQUIPMENT IN NUCLEAR POWER GENERATING STATIONS |
PIP ELEGL03 : 2016
|
GUIDELINES FOR POWER SYSTEMS ANALYSIS |
IEEE 3007.1 : 2010
|
RECOMMENDED PRACTICE FOR THE OPERATION AND MANAGEMENT OF INDUSTRIAL AND COMMERCIAL POWER SYSTEMS |
IEEE 844 : 2000
|
IEEE RECOMMENDED PRACTICE FOR ELECTRICAL IMPEDANCE, INDUCTION, AND SKIN EFFECT HEATING OF PIPELINES AND VESSELS |
IEEE DRAFT 400.1 : D8 2006
|
FIELD TESTING OF LAMINATED DIELECTRIC, SHIELDED POWER CABLE SYSTEMS RATED 5 KV AND ABOVE WITH HIGH DIRECT CURRENT VOLTAGE |
IEEE DRAFT C37.95 : D6 99
|
DRAFT GUIDE FOR PROTECTIVE RELAYING OF UTILITY CONSUMER INTERCONNECTIONS |
IEEE 3007.3 : 2012
|
RECOMMENDED PRACTICE FOR ELECTRICAL SAFETY IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS |
FIPS PUB 94 : 0
|
GUIDELINE ON ELECTRICAL POWER FOR ADP INSTALLATIONS |
IEEE DRAFT 1036 : D13A 2006
|
APPLICATION OF SHUNT POWER CAPACITORS |
NEMA ICS 3 : 2005(R2010)
|
INDUSTRIAL CONTROL AND SYSTEMS: MEDIUM VOLTAGE CONTROLLERS RATED 2001 TO 7200 VOLTS AC |
IEC PAS 80005-3 : 1ED 2014
|
UTILITY CONNECTIONS IN PORT - PART 3: LOW VOLTAGE SHORE CONNECTION (LVSC) SYSTEMS - GENERAL REQUIREMENTS |
IEEE DRAFT 1234 : D12 2007
|
FAULT LOCATING TECHNIQUES ON SHIELDED POWER CABLE SYSTEMS |
CSA C22.2 No. 273 : 2014(R2019)
|
CABLEBUS |
IEEE DRAFT 1242 : D4 99
|
DRAFT GUIDE FOR SPECIFYING AND SELECTING POWER, CONTROL AND SPECIAL PURPOSE CABLE FOR PETROLEUM AND CHEMICAL PLANTS |
IEEE DRAFT C37.100.1 : D9 2007
|
COMMON REQUIREMENTS FOR HIGH VOLTAGE POWER SWITCHGEAR RATED ABOVE 1000 V |
IEEE 1020 : 2011
|
GUIDE FOR CONTROL OF SMALL (100 KVA TO 5 MVA) HYDROELECTRIC POWER PLANTS |
IEEE C37.302 : 2015
|
FAULT CURRENT LIMITER (FCL) TESTING OF FCLS RATED ABOVE 1000 V AC |
IEEE 3001.8 : 2013
|
RECOMMENDED PRACTICE FOR THE INSTRUMENTATION AND METERING OF INDUSTRIAL AND COMMERCIAL POWER SYSTEMS |
IEEE C37.95 : 2014
|
GUIDE FOR PROTECTIVE RELAYING OF UTILITY-CONSUMER INTERCONNECTIONS |
ANSI C37.121 : 2012
|
AMERICAN NATIONAL STANDARD FOR SWITCHGEAR - UNIT SUBSTATIONS - REQUIREMENTS |
IEEE 277 : 2007
|
CEMENT PLANT POWER DISTRIBUTION |
IEEE 1349 : 2011
|
GUIDE FOR THE APPLICATION OF ELECTRIC MOTORS IN CLASS 1, DIVISION 2 AND CLASS 1, ZONE 2 HAZARDOUS (CLASSIFIED) LOCATIONS |
IEEE 1584.1 : 2013
|
SPECIFICATION OF SCOPE AND DELIVERABLE REQUIREMENTS FOR AN ARC-FLASH HAZARD CALCULATION STUDY IN ACCORDANCE WITH IEEE STD 1584 |
IEEE 551 : 2006
|
CALCULATING SHORT-CIRCUIT CURRENTS IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS |
IEEE 1453 : 2015
|
RECOMMENDED PRACTICE FOR THE ANALYSIS OF FLUCTUATING INSTALLATIONS ON POWER SYSTEMS |
IEEE 1623 : 2004
|
GUIDE FOR THE FUNCTIONAL SPECIFICATION OF MEDIUM VOLTAGE (1 KV - 35 KV) ELECTRONIC SHUNT DEVICES FOR DYNAMIC VOLTAGE COMPENSATION |
IEEE 2030.2 : 2015
|
GUIDE FOR THE INTEROPERABILITY OF ENERGY STORAGE SYSTEMS INTEGRATED WITH THE ELECTRIC POWER INFRASTRUCTURE |
IEEE C37.121 : 2012
|
GUIDE FOR SWITCHGEAR - UNIT SUBSTATION - REQUIREMENTS |
IEEE C37.230 : 2007
|
GUIDE FOR PROTECTIVE RELAY APPLICATIONS TO DISTRIBUTION LINES |
IEEE 1653.4 : 2011
|
DC TRACTION POWER SYSTEM FIELD TESTING AND ACCEPTANCE CRITERIA FOR SYSTEM APPLICATIONS UP TO 1500 V DC NOMINAL |
IEEE 1709 : 2010
|
RECOMMENDED PRACTICE FOR 1 KV TO 35 KV MEDIUM-VOLTAGE DC POWER SYSTEMS ON SHIPS |
IEEE DRAFT C37.48.1 : D13 2000
|
DRAFT GUIDE FOR THE OPERATION, CLASSIFICATION, APPLICATION AND COORDINATION OF CURRENT-LIMITING FUSES WITH RATED VOLTAGES 1-38 KV |
IEEE 1234 : 2007
|
FAULT-LOCATING TECHNIQUES ON SHIELDED POWER CABLE SYSTEMS |
IEEE 463 : 2013
|
ELECTRICAL SAFETY PRACTICES IN ELECTROLYTIC CELL LINE WORKING ZONES |
IEEE 3006.2 : 2016
|
RECOMMENDED PRACTICE FOR EVALUATING THE RELIABILITY OF EXISTING INDUSTRIAL AND COMMERCIAL POWER SYSTEMS |
IEEE 1792 : 2011
|
NUCLEAR POWER GENERATING STATION PREFERRED POWER SUPPLY RELIABILITY |
NETA ATS : 2017
|
ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS |
PIP ELCGL01 : 2013
|
ELECTRICAL DESIGN CRITERIA |
IEEE DRAFT C37.230 : D4.0 2006
|
PROTECTIVE RELAY APPLICATIONS TO DISTRIBUTION LINES |
IEEE 1159 : 2009
|
RECOMMENDED PRACTICE FOR MONITORING ELECTRIC POWER QUALITY |
IEC/ISO/IEEE 80005-1 : 2012
|
COLD IRONING - PART 1: HIGH VOLTAGE SHORE CONNECTION (HVSC) SYSTEMS - GENERAL REQUIREMENTS |
IEC TR 62655 : 1ED 2013
|
TUTORIAL AND APPLICATION GUIDE FOR HIGH-VOLTAGE FUSES |
API 14FZ : 2013
|
RECOMMENDED PRACTICE FOR DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, ZONE 0, ZONE 1, AND ZONE 2 LOCATIONS |
(INACTIVE RECORD) API 540 : 1999
|
ELECTRICAL INSTALLATIONS IN PETROLEUM PROCESSING PLANTS |
API 14F REDLINE : 2008
|
DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
16/30347549 DC : 0
|
BS EN 80005-3 - UTILITY CONNECTIONS IN PORT - PART 3: LOW VOLTAGE SHORE CONNECTION (LVSC) SYSTEMS - GENERAL REQUIREMENTS |
16/30337938 DC : 0
|
BS EN 80005-1 - UTILITY CONNECTIONS IN PORT - HIGH VOLTAGE SHORE CONNECTION (HVSC) SYSTEMS - PART 1: GENERAL REQUIREMENTS |
IEEE 741 : 2007
|
CRITERIA FOR THE PROTECTION OF CLASS 1E POWER SYSTEMS AND EQUIPMENT IN NUCLEAR POWER GENERATING STATIONS |
API 14F:2008
|
DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
API 540:1999
|
ELECTRICAL INSTALLATIONS IN PETROLEUM PROCESSING PLANTS |
API 14F : 2008 : R2013
|
DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
API 540 : 1999 : R2006
|
ELECTRICAL INSTALLATIONS IN PETROLEUM PROCESSING PLANTS |
(INACTIVE RECORD) API 14F : 2008
|
DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
NFPA 780 : 2017
|
INSTALLATION OF LIGHTNING PROTECTION SYSTEMS |
NFPA 70B : 2016
|
RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE |
IEEE 3001.2 : 2017
|
RECOMMENDED PRACTICE FOR EVALUATING THE ELECTRICAL SERVICE REQUIREMENTS OF INDUSTRIAL AND COMMERCIAL POWER SYSTEMS |