1. Scope
2. References
3. Definitions, acronyms and abbreviations
   3.1 Definitions
   3.2 Acronyms and abbreviations
4. General Considerations
   4.1 Overvoltages
   4.2 Metal-Oxide arresters
   4.3 Protective levels
   4.4 Insulation withstand
   4.5 Separation effects
   4.6 Insulation coordination
5. Protection of transmission equipment and substations
   5.1 Introduction
   5.2 Transformer protection, step-by-step procedures
   5.3 Special Considerations for Protection of Transformers
   5.4 Protection of dry-type insulation
   5.5 Special considerations for shunt capacitor bank applications
   5.6 Protection of underground transmission cables
   5.7 Protection of gas-insulated substations (GIS)
   5.8 Protection of high-power static devices and systems
   5.9 Protection of series capacitor banks
   5.10 Protection of circuit breakers
6. Protection of distribution systems
   6.1 Introduction
   6.2 General procedure
   6.3 Selection of arrester ratings
   6.4 Distribution system overvoltages
   6.5 Insulation coordination
   6.6 Arrester connections
   6.7 Special applications
   6.8 Isolation
7. Protection of overhead lines
   7.1 General Considerations
   7.2 Transmission Line Protection
   7.3 Distribution Line Protection
8. Protection of electrical machines, 1000 V and greater
   8.1 Insulation withstand tests
   8.2 Methods of surge protection for motors started across-the
        line (full voltage start)
Annex A (informative) Lightning flashes, lightning stroke currents,
                      traveling waves, and station shielding
   A.1 Lightning flashes and strokes
   A.2 Arrester currents due to lightning strokes
   A.3 Line shielding
   A.4 Station shielding
   A.5 Uses of shielding in station protection applications
   A.6 Traveling waves
Annex B (informative) COG for various conditions
Annex C (informative) Calculations of surge arrester separation
                      distances
   C.1 Purpose
   C.2 Introduction
   C.3 Definitions of symbols
   C.4 Study Method
   C.5 Selection of S', the steepness or rate of rise of the
        incoming surge
   C.6 Single-line single-transformer substation, example 1
   C.7 Three-line two-transformer substation
   C.8 Presentation of Figure C.8
Annex D (informative) Distribution system overvoltage line diagrams
Annex E (informative) Dual transformer station
Annex F (informative) Modeling of gapless metal-oxide surge arresters
   F.1 Introduction
   F.2 Recommended model for temporary overvoltage and switching
        surge studies
   F.3 Recommended model for lightning studies
Annex G (informative) "Rules of thumb" for some common arrester
                      energy discharge cases
   G.1 Switching surge energy discharge
   G.2 Arrester energy requirement for shunt capacitor application
Annex H (informative) Bibliography

Covers application of metal oxide surge arresters to safeguard electric power equipment against the hazards of abnormally high voltage surges of various origins.

DocumentType
Draft
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded

IEEE 525-2007 IEEE Guide for the Design and Installation of Cable Systems in Substations
IEEE 1313.1-1996 IEEE Standard for Insulation Coordination - Definitions, Principles and Rules
IEEE C57.12.01-2015 REDLINE IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers
IEEE C62.21 : 2003 GUIDE FOR THE APPLICATION OF SURGE VOLTAGE PROTECTIVE EQUIPMENT ON AC ROTATING MACHINERY 1000 V AND GREATER
IEEE 998-2012 IEEE Guide for Direct Lightning Stroke Shielding of Substations
IEEE 532-2007 REDLINE IEEE Guide for Selecting and Testing Jackets for Power, Instrumentation, and Control Cables
IEEE 1299/C62.22.1 : 1996 GUIDE FOR THE CONNECTION OF SURGE ARRESTERS TO PROTECT INSULATED, SHIELDED ELECTRIC POWER CABLE SYSTEMS
IEEE C57.12.00-2015 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
IEEE 1243:1997 GUIDE FOR IMPROVING THE LIGHTNING PERFORMANCE OF TRANSMISSION LINES
IEEE C37.015-2009 IEEE Guide for the Application of Shunt Reactor Switching
IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
IEEE 422-2012 IEEE Guide for the Design of Cable Raceway Systems for Electric Generating Facilities
IEEE C57.21 : 2008 REQUIREMENTS, TERMINOLOGY, AND TEST CODE FOR SHUNT REACTORS RATED OVER 500 KVA
IEEE C37.04-1999 IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers
IEEE 575-2014 IEEE Guide for Bonding Shields and Sheaths of Single-Conductor Power Cables Rated 5 kV through 500 kV

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.