ISO 7886-1:2017

Current
Current

The latest, up-to-date edition.

Sterile hypodermic syringes for single use — Part 1: Syringes for manual use
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English, French

Published date

05-03-2017

ISO 7886-1:2017 specifies requirements and test methods for verifying the design of empty sterile single-use hypodermic syringes, with or without needle, made of plastic or other materials and intended for the aspiration and injection of fluids after filling by the end-users. This document does not provide requirements for lot release. The syringes are primarily for use in humans.

Sterile syringes specified in this document are intended for use immediately after filling and are not intended to contain the medicament for extended periods of time.

It excludes syringes for use with insulin (see ISO 8537), single-use syringes made of glass, syringes for use with power-driven syringe pumps, syringes pre-filled by the manufacturer, and syringes intended to be stored after filling (e.g. in a kit for filling by a pharmacist).

Hypodermic syringes without a needle specified in this document are intended for use with hypodermic needles specified in ISO 7864.

DevelopmentNote
Supersedes ISO/DIS 7886-1. (05/2017)
DocumentType
Standard
Pages
28
PublisherName
International Organization for Standardization
Status
Current
Supersedes

BS ISO 11040-6:2012 Prefilled syringes Plastic barrels for injectables
10/30212297 DC : 0 BS ISO 11040-6 - PREFILLED SYRINGES - PART 6: PLASTIC BARRELS FOR INJECTABLES
13/30276989 DC : 0 BS EN ISO 11070 - STERILE, SINGLE-USE INTRAVASCULAR CATHETER INTRODUCERS
03/113406 DC : DRAFT OCT 2003 ISO 7886-3 - STERILE HYPODERMIC SYRINGES FOR SINGLE USE - PART 3: AUTO-DISABLE SYRINGES FOR FIXED DOSE IMMUNIZATION
UNI EN 13976-2 : 2011 RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 2: SYSTEM REQUIREMENTS
12/30266576 DC : 0 BS EN 13718-2 - MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 2: OPERATIONAL AND TECHNICAL REQUIREMENTS OF AIR AMBULANCES
17/30350521 DC : 0 BS EN ISO 7886-4 - STERILE HYPODERMIC SYRINGES FOR SINGLE USE - PART 4: SYRINGES WITH RE-USE PREVENTION FEATURE
I.S. EN ISO 10555-1:2013 INTRAVASCULAR CATHETERS - STERILE AND SINGLE-USE CATHETERS - PART 1: GENERAL REQUIREMENTS (ISO 10555-1:2013/AMD 1:2017)
EN ISO 7886-4:2009 Sterile hypodermic syringes for single use - Part 4: Syringes with re-use prevention feature (ISO 7886-4:2006)
EN ISO 22413:2013 Transfer sets for pharmaceutical preparations - Requirements and test methods (ISO 22413:2010)
I.S. EN ISO 22413:2013 TRANSFER SETS FOR PHARMACEUTICAL PREPARATIONS - REQUIREMENTS AND TEST METHODS (ISO 22413:2010)
AAMI CN6 : 2015 SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 6: CONNECTORS FOR NEURAXIAL APPLICATIONS
UNI EN ISO 7886-4 : 2009 STERILE HYPODERMIC SYRINGES FOR SINGLE USE - PART 4: SYRINGES WITH RE-USE PREVENTION FEATURE
UNE-EN ISO 80369-6:2016 Small bore connectors for liquids and gases in healthcare applications - Part 6: Connectors for neuraxial applications (ISO 80369-6:2016, Corrected version 2016-11-15)
DIN EN ISO 11070:2015-03 STERILE SINGLE-USE INTRAVASCULAR INTRODUCERS, DILATORS AND GUIDEWIRES (ISO 11070:2014)
EN 13718-2:2015 Medical vehicles and their equipment - Air ambulances - Part 2: Operational and technical requirements for air ambulances
ISO 80369-3:2016 Small-bore connectors for liquids and gases in healthcare applications — Part 3: Connectors for enteral applications
DIN EN ISO 7886-4:2010-01 STERILE HYPODERMIC SYRINGES FOR SINGLE USE - PART 4: SYRINGES WITH RE-USE PREVENTION FEATURE
DIN EN ISO 21649:2010-01 Needle-free injectors for medical use - Requirements and test methods (ISO 21649:2006)
ISO 12505-1:2014 Skin barrier for ostomy aids Test methods Part 1: Size, surface pH and water-absorbency
17/30345938 DC : 0 BS ISO 20698 - CATHETER SYSTEMS FOR NEURAXIAL APPLICATION - STERILE AND SINGLE-USE CATHETERS AND ACCESSORIES
I.S. EN ISO 80369-6:2016 SMALL BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 6: CONNECTORS FOR NEURAXIAL APPLICATIONS (ISO/IEC/DIS 80369-6:2014)
17/30357741 DC : 0 BS ISO 11040-6 - PREFILLED SYRINGES - PART 6: PLASTIC BARRELS FOR INJECTABLES AND STERILIZED SUBASSEMBLED SYRINGES READY FOR FILLING
DIN ISO 11040-4 E : 2017 PREFILLED SYRINGES - PART 4: GLASS BARRELS FOR INJECTABLES AND STERILIZED SUBASSEMBLED SYRINGES READY FOR FILLING (ISO 11040-4:2015)
BS ISO 11040-4:2015 Prefilled syringes Glass barrels for injectables and sterilized subassembled syringes ready for filling
BS EN ISO 80369-3:2016 Small-bore connectors for liquids and gases in healthcare applications Connectors for enteral applications
ISO 20905:2004 Coal preparation — Determination of dust/moisture relationship for coal
BS EN ISO 10555-1 : 2013 INTRAVASCULAR CATHETERS - STERILE AND SINGLE-USE CATHETERS - PART 1: GENERAL REQUIREMENTS
ISO 80369-6:2016 Small bore connectors for liquids and gases in healthcare applications — Part 6: Connectors for neuraxial applications
UNE-EN 13976-2:2011 Rescue systems - Transportation of incubators - Part 2: System requirements
BS EN ISO 11070 : 2014 STERILE SINGLE-USE INTRAVASCULAR INTRODUCERS, DILATORS AND GUIDEWIRES
I.S. EN ISO 80369-3:2016 SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 3: CONNECTORS FOR ENTERAL APPLICATIONS (ISO/IEC/DIS 80369-3:2014)
ISO 11040-8:2016 Prefilled syringes — Part 8: Requirements and test methods for finished prefilled syringes
I.S. EN ISO 11070:2014 STERILE SINGLE-USE INTRAVASCULAR INTRODUCERS, DILATORS AND GUIDEWIRES (ISO 11070:2014)
ISO 11070:2014 Sterile single-use intravascular introducers, dilators and guidewires
BS EN ISO 80369-6:2016 Small bore connectors for liquids and gases in healthcare applications Connectors for neuraxial applications
BS EN ISO 7886-4:2009 Sterile hypodermic syringes for single use Syringes with re-use prevention feature
BS EN ISO 8871-1:2004 Elastomeric parts for parenterals and for devices for pharmaceutical use Extractables in aqueous autoclavates
UNE-EN ISO 11608-3:2013 Needle-based injection systems for medical use - Requirements and test methods - Part 3: Finished containers (ISO 11608-3:2012)
BS EN ISO 7886-3:2009 Sterile hypodermic syringes for single use Auto-disable syringes for fixed-dose immunization
DIN EN ISO 7886-3:2010-01 STERILE HYPODERMIC SYRINGES FOR SINGLE USE - PART 3: AUTO-DISABLE SYRINGES FOR FIXED-DOSE IMMUNIZATION
UNI EN ISO 7886-3 : 2009 STERILE HYPODERMIC SYRINGES FOR SINGLE USE - PART 3: AUTO-DISABLE SYRINGES FOR FIXED-DOSE IMMUNIZATION
I.S. EN ISO 21649:2009 NEEDLE-FREE INJECTORS FOR MEDICAL USE - REQUIREMENTS AND TEST METHODS
I.S. EN ISO 11608-3:2012 NEEDLE-BASED INJECTION SYSTEMS FOR MEDICAL USE - REQUIREMENTS AND TEST METHODS - PART 3: FINISHED CONTAINERS (ISO 11608-3:2012)
UNI EN ISO 11070 : 2015 STERILE SINGLE-USE INTRAVASCULAR INTRODUCERS, DILATORS AND GUIDEWIRES
16/30339096 DC : 0 BS EN ISO 7886-3 - STERILE HYPODERMIC SYRINGES FOR SINGLE USE - PART 3: AUTO-DISABLE SYRINGES FOR FIXED-DOSE IMMUNIZATION
13/30284773 DC : 0 BS EN ISO 8536-10 - INFUSION EQUIPMENT FOR MEDICAL USE - PART 10: ACCESSORIES FOR FLUID LINES FOR USE WITH PRESSURE INFUSION EQUIPMENT
13/30273499 DC : 0 BS ISO 11040-4 - PREFILLED SYRINGES - PART 4: GLASS BARRELS FOR INJECTABLES AND STERILIZED SUBASSEMBLED SYRINGES READY FOR FILLING
02/564517 DC : DRAFT OCT 2002 BS EN ISO 8536-10 - INFUSION EQUIPMENT FOR MEDICAL USE - PART 10: ACCESSORIES FOR FLUID LINES FOR USE WITH PRESSURE INFUSION EQUIPMENT
11/30228364 DC : 0 BS EN ISO 10555-1 - INTRAVASCULAR CATHETERS - STERILE AND SINGLE-USE CATHETERS - PART 1: GENERAL REQUIREMENTS
DIN EN ISO 22413:2013-10 Transfer sets for pharmaceutical preparations - Requirements and test methods (ISO 22413:2010)
EN ISO 10555-1:2013/A1:2017 INTRAVASCULAR CATHETERS - STERILE AND SINGLE-USE CATHETERS - PART 1: GENERAL REQUIREMENTS (ISO 10555-1:2013/AMD 1:2017)
DIN EN ISO 7886-4 E : 2010 STERILE HYPODERMIC SYRINGES FOR SINGLE USE - PART 4: SYRINGES WITH RE-USE PREVENTION FEATURE
ISO 7886-4:2006 Sterile hypodermic syringes for single use Part 4: Syringes with re-use prevention feature
NF EN ISO 7886-3 : 2009 STERILE HYPODERMIC SYRINGES FOR SINGLE USE - PART 3: AUTO-DISABLE SYRINGES FOR FIXED-DOSE IMMUNIZATION
DIN EN ISO 7886-3 E : 2010 STERILE HYPODERMIC SYRINGES FOR SINGLE USE - PART 3: AUTO-DISABLE SYRINGES FOR FIXED-DOSE IMMUNIZATION
DIN EN ISO 11608-3 E : 2013 NEEDLE-BASED INJECTION SYSTEMS FOR MEDICAL USE - REQUIREMENTS AND TEST METHODS - PART 3: FINISHED CONTAINERS (ISO 11608-3:2012)
DIN EN 13718-2:2015-05 MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 2: OPERATIONAL AND TECHNICAL REQUIREMENTS FOR AIR AMBULANCES
BS EN ISO 21649:2009 Needle-free injectors for medical use. Requirements and test methods
UNE-EN 13718-2:2015 Medical vehicles and their equipment - Air ambulances - Part 2: Operational and technical requirements for air ambulances
ISO 21649:2006 Needle-free injectors for medical use — Requirements and test methods
EN ISO 7886-3:2009 Sterile hypodermic syringes for single use - Part 3: Auto-disable syringes for fixed-dose immunization (ISO 7886-3:2005)
I.S. EN ISO 7886-3:2009 STERILE HYPODERMIC SYRINGES FOR SINGLE USE - PART 3: AUTO-DISABLE SYRINGES FOR FIXED-DOSE IMMUNIZATION
ONORM EN 13718-2 : 2015 MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 2: OPERATIONAL AND TECHNICAL REQUIREMENTS FOR AIR AMBULANCES
UNI EN ISO 11608-3 : 2013 NEEDLE-BASED INJECTION SYSTEMS FOR MEDICAL USE - REQUIREMENTS AND TEST METHODS - PART 3: FINISHED CONTAINERS
PREN 13976-2 : DRAFT 2016 RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 2: SYSTEM REQUIREMENTS
UNI EN ISO 21649 : 2009 NEEDLE-FREE INJECTORS FOR MEDICAL USE - REQUIREMENTS AND TEST METHODS
15/30304642 DC : 0 BS ISO 11040-8 - PREFILLED SYRINGES - PART 8: REQUIREMENTS AND TEST METHODS FOR FINISHED PRIFILLED SYRINGES
ANSI/AAMI/ISO 80369-3:2016 SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 3: CONNECTORS FOR ENTERAL APPLICATIONS
BS ISO 7886-2 : 1996 AMD 9835 STERILE HYPODERMIC SYRINGES FOR SINGLE USE - SYRINGES FOR USE WITH POWER-DRIVEN SYRINGE PUMPS
BS ISO 12505-1:2014 Skin barrier for ostomy aids. Test methods Size, surface pH and water-absorbency
16/30333925 DC : 0 BS EN 13976-2 - RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 2: SYSTEM REQUIREMENTS
UNE-EN ISO 80369-3:2017 Small-bore connectors for liquids and gases in healthcare applications - Part 3: Connectors for enteral applications (ISO 80369-3:2016)
10/30197474 DC : 0 BS ISO 12505 - SKIN BARRIER FOR OSTOMY AIDS - TEST METHODS
BS EN ISO 22413:2013 Transfer sets for pharmaceutical preparations. Requirements and test methods
ANSI/AAMI/ISO 80369-6:2016 SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 6: CONNECTORS FOR NEURAXIAL APPLICATIONS
ISO 11040-4:2015 Prefilled syringes Part 4: Glass barrels for injectables and sterilized subassembled syringes ready for filling
I.S. EN ISO 7886-4:2009 STERILE HYPODERMIC SYRINGES FOR SINGLE USE - PART 4: SYRINGES WITH RE-USE PREVENTION FEATURE
I.S. EN 13976-2:2011 RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 2: SYSTEM REQUIREMENTS
DIN EN ISO 21649 E : 2010 NEEDLE-FREE INJECTORS FOR MEDICAL USE - REQUIREMENTS AND TEST METHODS
BS EN 13976-2:2011 Rescue systems. Transportation of incubators System requirements
BS EN ISO 7886-2:1997 Sterile hypodermic syringes for single use Syringes for use with power-driven syringe pumps
BS EN ISO 11608-3:2012 Needle-based injection systems for medical use. Requirements and test methods Finished containers
UNE-EN ISO 22413:2013 Transfer sets for pharmaceutical preparations - Requirements and test methods (ISO 22413:2010)
BS EN 13718-2:2015 Medical vehicles and their equipment. Air ambulances Operational and technical requirements for air ambulances
UNE-EN ISO 11070:2015 Sterile single-use intravascular introducers, dilators and guidewires (ISO 11070:2014)
EN ISO 7886-2 : 1997 STERILE HYPODERMIC SYRINGES FOR SINGLE USE - SYRINGES FOR USE WITH POWER-DRIVEN SYRINGE PUMPS
I.S. EN 13718-2:2015 MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 2: OPERATIONAL AND TECHNICAL REQUIREMENTS FOR AIR AMBULANCES
ISO 8871-1:2003 Elastomeric parts for parenterals and for devices for pharmaceutical use Part 1: Extractables in aqueous autoclavates
DIN EN 13976-2 E : 2011 RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 2: SYSTEM REQUIREMENTS
ISO 11608-3:2012 Needle-based injection systems for medical use Requirements and test methods Part 3: Finished containers
I.S. EN 13718-2:2015+A1:2020 MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 2: OPERATIONAL AND TECHNICAL REQUIREMENTS FOR AIR AMBULANCES
BS EN 30-1-2:2012 Domestic cooking appliances burning gas. Safety Appliances having forced-convection ovens and/or grills
EN 30-1-2:2012 Domestic cooking appliances burning gas - Safety - Part 1-2: Appliances having forced-convection ovens and/or grills
EN ISO 21649:2009 Needle-free injectors for medical use - Requirements and test methods (ISO 21649:2006)
EN 1707 : 1996 CONICAL FITTINGS WITH A 6 % (LUER) TAPER FOR SYRINGES, NEEDLES AND CERTAIN OTHER MEDICAL EQUIPMENT - LOCK FITTINGS
EN ISO 80369-3:2016 Small-bore connectors for liquids and gases in healthcare applications - Part 3: Connectors for enteral applications (ISO 80369-3:2016)
EN ISO 11608-3:2012 Needle-based injection systems for medical use - Requirements and test methods - Part 3: Finished containers (ISO 11608-3:2012)
EN ISO 8871-1 : 2004 ELASTOMERIC PARTS FOR PARENTERALS AND FOR DEVICES FOR PHARMACEUTICAL USE - PART 1: EXTRACTABLES IN AQUEOUS AUTOCLAVATES
ONORM EN ISO 11070 : 2015 STERILE SINGLE-USE INTRAVASCULAR INTRODUCERS, DILATORS AND GUIDEWIRES (ISO 11070:2014)
03/301319 DC : 0 ISO 20905 - COAL PREPARATION - DETERMINATION OF DUST/MOISTURE RELATIONSHIP FOR COAL
ISO 11040-6:2012 Prefilled syringes Part 6: Plastic barrels for injectables
DIN ISO 11040-4:2007-10 PREFILLED SYRINGES - PART 4: GLASS BARRELS FOR INJECTABLES AND STERILIZED SUBASSEMBLED SYRINGES READY FOR FILLING (ISO 11040-4:2015)
BS ISO 22413:2010 Transfer sets for pharmaceutical preparations. Requirements and test methods
03/113382 DC : DRAFT SEP 2003 BS EN ISO 21649 - NEEDLE-FREE INJECTORS FOR MEDICAL USE - REQUIREMENTS AND TEST METHODS
ISO 10555-1:2013 Intravascular catheters — Sterile and single-use catheters — Part 1: General requirements
EN ISO 80369-6 : 2016 COR 2016 SMALL BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 6: CONNECTORS FOR NEURAXIAL APPLICATIONS (ISO 80369-6:2016, CORRECTED VERSION 2016-11-15)
NF EN ISO 7886-4 : 2009 STERILE HYPODERMIC SYRINGES FOR SINGLE USE - PART 4: SYRINGES WITH RE-USE PREVENTION FEATURE
EN 13976-2:2011 Rescue systems - Transportation of incubators - Part 2: System requirements
DIN EN 13976-2:2016-03 (Draft) RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 2: SYSTEM REQUIREMENTS
ISO 22413:2010 Transfer sets for pharmaceutical preparations Requirements and test methods
DIN EN ISO 11608-3:2013-01 Needle-based injection systems for medical use - Requirements and test methods - Part 3: Finished containers (ISO 11608-3:2012)
UNI EN ISO 22413 : 2013 TRANSFER SETS FOR PHARMACEUTICAL PREPARATIONS - REQUIREMENTS AND TEST METHODS
DIN EN 13976-2:2011-08 RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 2: SYSTEM REQUIREMENTS
DIN ISO 11040-4:2017-07 PREFILLED SYRINGES - PART 4: GLASS BARRELS FOR INJECTABLES AND STERILIZED SUBASSEMBLED SYRINGES READY FOR FILLING (ISO 11040-4:2015)

ISO 11607-2:2006 Packaging for terminally sterilized medical devices Part 2: Validation requirements for forming, sealing and assembly processes
ISO 15223-2:2010 Medical devices — Symbols to be used with medical device labels, labelling, and information to be supplied — Part 2: Symbol development, selection and validation
ISO 8537:2016 Sterile single-use syringes, with or without needle, for insulin
ISO 80369-20:2015 Small-bore connectors for liquids and gases in healthcare applications Part 20: Common test methods
ISO 384:2015 Laboratory glass and plastics ware Principles of design and construction of volumetric instruments
ISO 8601:2004 Data elements and interchange formats Information interchange Representation of dates and times
ISO 7864:2016 Sterile hypodermic needles for single use — Requirements and test methods
ISO 10993-1:2009 Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process
ISO 80369-7:2016 Small-bore connectors for liquids and gases in healthcare applications Part 7: Connectors for intravascular or hypodermic applications
ISO 23908:2011 Sharps injury protection Requirements and test methods Sharps protection features for single-use hypodermic needles, introducers for catheters and needles used for blood sampling
ISO 14971:2007 Medical devices Application of risk management to medical devices
ISO 11607-1:2006 Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems
ISO 15223-1:2016 Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements

View more information
US$175.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.