• There are no items in your cart

ISO 9073-12:2002

Current
Current

The latest, up-to-date edition.

Textiles Test methods for nonwovens Part 12: Demand absorbency
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English, French

Published date

10-30-2002

ISO 9073-12 describes a method for the evaluation of the absorbency of fabrics when one side is in contact with a liquid and the fabric is under mechanical pressure.

This test is designed to allow comparison of absorbent materials such as nonwovens and is not intended to simulate in-use conditions of finished products.

Demand absorbency is also called demand wettability.

DevelopmentNote
Supersedes ISO/DIS 9073-12 (10/2002)
DocumentType
Standard
Pages
12
PublisherName
International Organization for Standardization
Status
Current

17/30358658 DC : 0 BS EN 13795-1 - SURGICAL CLOTHING AND DRAPES - REQUIREMENTS AND TEST METHODS - PART 1: SURGICAL DRAPES AND GOWNS
I.S. EN 13795:2011 SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - GENERAL REQUIREMENTS FOR MANUFACTURERS, PROCESSORS AND PRODUCTS, TEST METHODS, PERFORMANCE REQUIREMENTS AND PERFORMANCE LEVELS
DIN EN 13795-2:2009-12 SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - PART 2: TEST METHODS
DIN EN 13795:2013-10 SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - GENERAL REQUIREMENTS FOR MANUFACTURERS, PROCESSORS AND PRODUCTS, TEST METHODS, PERFORMANCE REQUIREMENTS AND PERFORMANCE LEVELS
PREN 13795-1 : DRAFT 2017 SURGICAL CLOTHING AND DRAPES - REQUIREMENTS AND TEST METHODS - PART 1: SURGICAL DRAPES AND GOWNS
BS EN 13795:2011+A1:2013 Surgical drapes, gowns and clean air suits, used as medical devices for patients, clinical staff and equipment. General requirements for manufacturers, processors and products, test methods, performance requirements and performance levels
UNI EN 13795 : 2013 SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - GENERAL REQUIREMENTS FOR MANUFACTURERS, PROCESSORS AND PRODUCTS, TEST METHODS, PERFORMANCE REQUIREMENTS AND PERFORMANCE LEVELS
UNI EN 13795-2 : 2009 SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - PART 2: TEST METHODS
UNE-EN 13795:2011 Surgical drapes, gowns and clean air suits, used as medical devices for patients, clinical staff and equipment - General requirements for manufacturers, processors and products, test methods, performance requirements and performance levels
BS EN 13795-2 : 2004 SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - PART 2: TEST METHODS
EN 13795:2011+A1:2013 Surgical drapes, gowns and clean air suits, used as medical devices for patients, clinical staff and equipment - General requirements for manufacturers, processors and products, test methods, performance requirements and performance levels
EN 13795-2:2004+A1:2009 Surgical drapes, gowns and clean air suits, used as medical devices for patients, clinical staff and equipment - Part 2: Test methods
DIN EN 13795-2 E : 2009 SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - PART 2: TEST METHODS
I.S. EN 13795-2:2005 SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - PART 2: TEST METHODS

ISO 3696:1987 Water for analytical laboratory use — Specification and test methods
ISO 139:2005 Textiles Standard atmospheres for conditioning and testing

View more information
US$73.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.