WC 3-1992

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
Superseded date

11-01-2000

Published date

01-12-2013

Foreword
PART 1 - GENERAL
  Scope
  General Information
  Information to Be Supplied to Purchaser
PART 2 - CONDUCTORS
  Wires, Physical and Electrical Properties
  Solid Conductors
  Stranded Conductors
  Conductor Size Units
  Conductor DC Resistance per Unit Length
  Conductor Diameter
  Stress Control Layer
PART 3 - INSULATION
  Material
  Insulation Thicknesses
  Additional Insulation Thickness for non-sheathed
    Submarine Cables
  Series Lighting Circuits
  Repairs
  Insulation Grades and Requirements
  Synthetic Rubber, Moisture Resisting, 60 deg C
  Natural Rubber, 60 deg C
  Synthetic Rubber, 75 deg C
  Synthetic Rubber, Heat Resisting, 75 deg C or Moisture
    Resisting 60 deg C
  Natural Rubber 75 deg C
  Synthetic Rubber, Heat and Moisture Resisting, 75 deg C
  Ozone-resisting Natural or Synthetic Rubber
  Ozone-resisting Butyl Rubber
  Synthetic Rubber, 90 deg C
  Ozone-resisting Silicone Rubber
  Chlorosulfonated Polyethylene
PART 4 - SHIELDING AND COVERINGS
  Shielding
  Tapes, Braids, Wraps, and Servings
  Jackets
PART 5 - ASSEMBLY, FILLERS, BINDERS, AND CONDUCTOR
         IDENTIFICATION
  Assembly of Multiple-conductor Cables
  Multiple-conductor Round Cables
  Flat Twin Cables
  Fillers
  Binder
  Conductor Identification
PART 6 - TESTING AND TEST METHODS
  Testing
  Tests on Samples
  Conductor Test Methods
  Test Samples and Specimens for Physical and Aging Tests
  Short-time Dielectric Strength Test on Insulation
    Conductors
  Cold Bending and Long-time Dielectric Strength Test
  Capacity and Power Factor Tests
  Ozone Resisting Tests
  Accelerated Water Absorption Tests
  Thickness of Tapes
  Measurements of Braids
  Determination of Yarn Size of Wraps
  Braided Cables for Indoor Installations
  Saturant for Fibrous Covering for Aerial Cables
  Braided Cables for Outdoor Installations
  Saturant for Fibrous Covering for Aerial Cables
  Braided Cables for Outdoor Installations
  Fibrous or Composite Jackets
  Thickness of Metallic Sheaths
  Thickness of Jute Beddings and Servings
  Tests for Thermoplastic Jackets
  Tests for Discharge-resisting Jackets
  Volume Resistivity
  Stripping Test
  Retests for Tests on Samples (Except Physical and Aging
    Tests)
  Voltage Tests
  Insulation Resistance
  Partial Discharge Test Procedure
  Method for Flexibility Test for Continuously Corrugated
    Armor
  Method for Determining Permittivity (SIC) and Dielectric
    Strength of Exuded Nonconducting Polymeric Stress
    Control Layers
PART 7 - CONSTRUCTIONS OF SPECIFIC TYPES
  Mine Power Cables
  Preassembled Aerial Cables
  Portable Arc-welding Cables
  Control Cables
  Primary Underground Residential Distribution Cables -
    Butyl Rubber Insulated
  Metal-clad Cables with Grounding Conductor
  Nonshielded Single-conductor Power Cable
PART 8 - APPENDICES
  Abbreviations and Symbols
  Representative Tensile Strength and Elongation of Non-
    magnetic Metals
  Definitions for Maximum Temperature of Conductors in
    Insulated Wire and Cable
  Emergency Overload Ratings for Rubber-Insulated Cables
  Referenced ICEA Publications and ASTM Standards
  Shielding
  Recommended Bending Radii for Cables
  Ampacities for Three-conductor Mine Power Cables 2001
    to 15000 Volts copper and Aluminium
  Conductor Identification for Control Cables
  Additional Conductor Information
  Ampacities for Preassembled Aerial Cables

These standards apply to materials, constructions and testing of rubber-insulated wires and cables which are used for the transmission and distribution of electrical energy for normal conditions of installation and service, either indoors, aerial, underground, or submarine.

DocumentType
Standard
PublisherName
National Electrical Manufacturers Association
Status
Superseded
SupersededBy

A-A-50304 Base Document:1987 DYNAMOMETER, ENGINE RUN-IN, 500 HORSEPOWER CAPACITY
EN 60947-1:2007/A2:2014 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014)
IEEE 241 : 1990 ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS
IEEE DRAFT 404 : D13 2006 EXTRUDED AND LAMINATED DIELECTRIC SHIELDED CABLE JOINTS RATED 2500 V - 500 000 V
IEEE 902-1998 IEEE Guide for Maintenance, Operation, and Safety of Industrial and Commercial Power Systems (Yellow Book)
IEEE 141 : 1993 IEEE Recommended Practice for Electric Power Distribution for Industrial Plants
IEEE 242-2001 IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book)
API 14F : 2008 : R2013 DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS
API 540:1999 ELECTRICAL INSTALLATIONS IN PETROLEUM PROCESSING PLANTS
TM 5-811-1 : V19950228 ARMY TECHNICAL MANUAL - ELECTRICAL POWER SUPPLY AND DISTRIBUTION
EN 61009-1:2012/A12:2016 RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES
EN 60898-1:2003/A13:2012 ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002, MODIFIED)
GGG-E-2814 Base Document:1993 ETCHERS, ELECTRIC, PORTABLE
API 540 : 1999 : R2006 ELECTRICAL INSTALLATIONS IN PETROLEUM PROCESSING PLANTS
MIL C 38359 : A CABLE, POWER, ELECTRICAL, AIRPORT LIGHTING, CROSS-LINKED, POLYETHYLENE XLP
MIL M 29212 : B NOTICE 1 MIXING PLANT, ASPHALT, DRUM TYPE, PORTABLE, ELECTRIC MOTOR DRIVEN, 120 TONS PER HOUR CAPACITY
MIL-L-741 Revision D:1984 LEAD, ELECTRICAL, ARC WELDING
MIL-C-82403 Base Document:1965 CABLE, SUBMARINE, POWER, CONTROL AND COMBINATION
EN 60999-2:2003 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm² up to 300 mm² (included)
API 14F:2008 DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS
EN 60999-1:2000 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included)
EN 60947-7-1:2009 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 7-1: ANCILLARY EQUIPMENT - TERMINAL BLOCKS FOR COPPER CONDUCTORS
MIL-C-11085 Revision D:1986 CONVEYOR, BELT; (FLAT, SKID-MOUNTED, ELECTRIC-MOTOR-DRIVEN, 24-INCH-WIDE BELT, 50-FOOT-LONG FRAME; CAPACITY, 25 POUNDS PER FOOT, 75 TONS PER HOUR)
EN 60998-2-1:2004 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units
BS EN 60947-1 : 2007 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES
BS EN 60947-7-1:2009 Low-voltage switchgear and controlgear Ancillary equipment. Terminal blocks for copper conductors
BS EN 60998-2-1:2004 Connecting devices for low-voltage circuits for household and similar purposes Particular requirements for connecting devices as separate entities with screw-type clamping units
CSA C22.2 No. 249 : 1996 : R2011 STANDARD TESTS FOR DETERMINING COMPATIBILITY OF CABLE-PULLING LUBRICANTS WITH WIRE AND CABLE
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
IEC 60999-1:1999 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included)
IEC 60947-7-1:2009 Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors
CAN/CSA-C22.2 NO. 60947-1-13 (R2018) Low-voltage switchgear and controlgear - Part 1: General rules (Tri-national standard, with UL 60947-1 and NMX-J-515-ANCE)
IEEE 1019-2013 REDLINE IEEE Recommended Practice for Specifying Electric Submersible Pump Cable—Polypropylene Insulation
EN 61008-1:2012/A12:2017 RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCBS) - PART 1: GENERAL RULES (IEC 61008-1:2010, MODIFIED)
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules
CSA C22.2 No. 249 : 1996 : R2015 STANDARD TESTS FOR DETERMINING COMPATIBILITY OF CABLE-PULLING LUBRICANTS WITH WIRE AND CABLE
BS EN 60898-1 : 2003 ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION
BS EN 61009-1 : 2012 RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES
IEC 60999-2:2003 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm2 up to 300 mm2 (included)
BS EN 60998-2-3:2004 Connecting devices for low-voltage circuits for household and similar purposes Particular requirements for connecting devices as separate entities with insulation-piercing clamping units
BS EN 61008-1 : 2012 RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCBS) - PART 1: GENERAL RULES (IEC 61008-1:2010, MODIFIED)
UNE-EN 61008-1:2013 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules
NEMA HP 100:1991(R2010) High-Temperature Instrumentation and Control Cables
API 14F REDLINE : 2008 DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS
I.S. EN 60947-1:2007 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES

ASTM D 3349 : 2017 : REDLINE Standard Test Method for Absorption Coefficient of Ethylene Polymer Material Pigmented with Carbon Black
ASTM B 174 : 2017 : REDLINE Standard Specification for Bunch-Stranded Copper Conductors for Electrical Conductors
ASTM B 29 : 2014 : REDLINE Standard Specification for Refined Lead
ASTM B 172 : 2017 : REDLINE Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors
ASTM B 496 : 2016 : REDLINE Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors
ASTM B 246 : 2015 : REDLINE Standard Specification for Tinned Hard-Drawn and Medium-Hard-Drawn Copper Wire for Electrical Purposes
ASTM D 257 : 2014 : REDLINE Standard Test Methods for DC Resistance or Conductance of Insulating Materials
ASTM E 8 : 2004 Standard Test Methods for Tension Testing of Metallic Materials
ASTM B 173 : 2017 : REDLINE Standard Specification for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members, for Electrical Conductors
ASTM D 471 : 2016-02 TEST METHOD FOR RUBBER PROPERTY - EFFECT OF LIQUIDS
ASTM D 746 : 2014 : REDLINE Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact
ASTM D 1693 : 2015 : REDLINE Standard Test Method for Environmental Stress-Cracking of Ethylene Plastics

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.