• There are no items in your cart

UTEC 93 533 : 2009

Current

Current

The latest, up-to-date edition.

CABLES WITH POLYVINYL CHLORIDE INSULATION AND POLYVINYL CHLORIDE SHEATH FOR CABLING AND INDOOR INSTALLATION OF TRANSMISSION EQUIPMENTS - GENERIC SPECIFICATION

Published date

01-12-2013

SECTION 1 - GENERALITES
1 INTRODUCTION
2 NORMES DE RÉFÉRENCE
3 ASSURANCE DE LA QUALITÉ
SECTION 2 - CONSTRUCTION DU CABLE
4 CONDUCTEUR
5 ENVELOPPE ISOLANTE
6 ÉLÉMENTS DE CABLAGE
7 MODE DE CABLAGE
8 PAIRES DE RÉSERVE
9 CODE DES COULEURS
10 REVETEMENT ET ÉCRAN DE L'AME
11 GAINE
12 FILIN DE DÉCHIREMENT
13 CABLE EN ÉTAT DE LIVRAISON
14 LIVRAISON
SECTION 3 - PRESCRIPTIONS MÉCANIQUES
15 CONDUCTEUR
16 ENVELOPPE ISOLANTE
17 GAINES
SECTION 4 - PRESCRIPTIONS THERMIQUES ET D'ENVIRONNEMENT
18 ENVELOPPE ISOLANTE
19 GAINE
20 COMPORTEMENT AU FEU
SECTION 5 - PRESCRIPTIONS ÉLECTRIQUES
21 RÉSISTANCE ÉLECTRIQUE DU CONDUCTEUR
22 RIGIDITÉ DIÉLECTRIQUE
23 RÉSISTANCE D'ISOLEMENT
ANNEXE A - CODE DES COULEURS PRÉFÉRENTIEL
ANNEXE B - CODE DES COULEURS DES ENVELOPPES ISOLANTES DES
           CABLES ASSEMBLÉS NE
DÉPASSANT PAS 60 ÉLÉMENTS
ANNEXE C - RIGIDITÉ SOUS CONTRAINTES MÉCANIQUES

Le présent document définit les conditions techniques auxquelles doivent répondre l'ensemble des câbles à isolation et gainage en polychlorure de vinyle destinés aux installations intérieures des équipements de transmission.

DevelopmentNote
Indice de classement: C93-533U. (02/2009) Supersedes NFC 93 533. (04/2009)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Current
Supersedes

UTEC 93 534-1 : 2009 CABLES WITH POLYVINYL CHLORIDE INSULATION AND POLYVINYL CHLORIDE SHEATH FOR CABLING AND INDOOR INSTALLATION OF TRANSMISSION EQUIPMENTS - DETAIL SPECIFICATION SERIES 282 FOR WIRES AND CABLES
UTEC 93 534-2 : 2009 CABLES WITH POLYVINYL CHLORIDE INSULATION AND POLYVINYL CHLORIDE SHEATH FOR CABLING AND INDOOR INSTALLATION OF TRANSMISSION EQUIPMENTS - DETAIL SPECIFICATION SERIES 281 FOR JUMPERS
UTEC 93 534-3 : 2009 CABLES WITH POLYVINYL CHLORIDE INSULATION AND POLYVINYL CHLORIDE SHEATH FOR CABLING AND INDOOR INSTALLATION OF TRANSMISSION EQUIPMENTS - DETAIL SPECIFICATION SERIES 282 FOR SCREENED ONE PAIR CABLES

NF EN 50289-3-8 : 2017 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 3-8: MECHANICAL TEST METHODS - ABRASION RESISTANCE OF CABLE SHEATH MARKINGS
IEC 60028:1925 International standard of resistance for copper
2006/95/EC : 2006 DIRECTIVE 2006/1995/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 12 DECEMBER 2006 ON THE HARMONISATION OF THE LAWS OF MEMBER STATES RELATING TO ELECTRICAL EQUIPMENT DESIGNED FOR USE WITHIN CERTAIN VOLTAGE LIMITS (CODIFIED VERSION) (TEXT WITH EEA RELEVANCE)
NFC 32 050 : 1990 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - METAL SHEATHED CABLES - RULES
IEC 60304:1982 Standard colours for insulation for low-frequency cables and wires
NF EN 50289-1-4 : 2001 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 1-4: ELECTRICAL TEST METHODS - INSULATION RESISTANCE
NF EN 50290-2-21 : 2002 AMD 1 2008 COMMUNICATION CABLES - PART 2-21: COMMON DESIGN RULES AND CONSTRUCTION - PVC INSULATION COMPOUNDS
NF EN 50289-3-4 : 2001 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 3-4: MECHANICAL TEST METHODS - TENSILE STRENGTH, ELONGATION AND SHRINKAGE OF INSULATION AND SHEATH
NF EN 50289-3-7 : 2001 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 3-7: MECHANICAL TEST METHODS - ABRASION RESISTANCE OF THE CABLE SHEATH
NF EN 50289-3-2 : 2001 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 3-2: MECHANICAL TEST METHODS - TENSILE STRENGTH AND ELONGATION FOR CONDUCTOR
NFX 08 002 : 1983 FD LIMITED COLLECTION OF COLOURS - DESIGNATION AND CATALOGUE OF CCR COLOURS - SECONDARY STANDARDS
NFC 31 111 : 1992 WIRES FOR ELECTRICAL MACHINERY AND APPARATUS - ROUND BARE ANNEALED COPPER WIRE - CHARACTERISTICS
NF EN 50290-4-1 : 2015 COMMUNICATION CABLES - PART 4-1: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - ENVIRONMENTAL CONDITIONS AND SAFETY ASPECTS
IEC TR 60344:2007 Calculation of d.c. resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide
NF EN 50289-3-9 : 2001 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 3-9: MECHANICAL TEST METHODS - BENDING TESTS
NF EN 60332-2-2 : 2005 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 2-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE SMALL INSULATED WIRE OR CABLE - PROCEDURE FOR DIFFUSION FLAME
NF EN 60811 1-1 : 96 AMD 1 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 1: MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING THE MECHANICAL PROPERTIES
NF EN 60332-2-1 : 2005 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 2-1: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE SMALL INSULATED WIRE OR CABLE - APPARATUS
NF EN 50289-1-2 : 2001 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 1-2: ELECTRICAL TEST METHOD - DC RESISTANCE
NF EN 50290-2-22 : 2002 AMD 1 2008 COMMUNICATION CABLES - PART 2-22: COMMON DESIGN RULES AND CONSTRUCTION - PVC SHEATHING COMPOUNDS
UTEC 32 063-3 : 2009 TOXICITY OF COMBUSTION GASES OF HALOGEN FREE MATERIALS FOR SHEATH USED IN COMMUNICATION CABLES WITH PARTICULAR FIRE RELATED PROPERTIES
NF EN 50289-1-3 : 2001 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 1-3: ELECTRICAL TEST METHOD - DIELECTRIC STRENGTH
NFC 32 062-1 : 1995 ELECTRONIC COMPONENTS - LOW CORROSIVE MATERIALS FOR INSULATION AND SHEATH USED IN COMMUNICATION CABLES WITH PARTICULAR FIRE RELATED PROPERTIES
NF EN 50290-2-1 : 2005 COMMUNICATION CABLES - PART 2-1: COMMON DESIGN RULES AND CONSTRUCTION

View more information
Sorry this product is not available in your region.