• There are no items in your cart

AAMI ES1 : 3ED 93

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

SAFE CURRENT LIMITS FOR ELECTROMEDICAL APPARATUS
Superseded date

03-09-2006

Published date

01-12-2013

Establishes risk-current limits and referee test procedures for electromedical apparatus intended for use in the vicinity of patient care. Limits for non-patient-contact electromedical apparatus are also set. Applicable to line- and battery-powered apparatus as well as to apparatus used singly or with properly connected accessory equipment.

Committee
ES
DevelopmentNote
Formerly it was SCL (05/2001)
DocumentType
Standard
PublisherName
Association for the Advancement of Medical Instrumentation
Status
Superseded
SupersededBy

Standards Relationship
IEC 60601-1:2005+AMD1:2012 CSV Corresponds

IEEE 1073.4.1 : 2000 STANDARD FOR MEDICAL DEVICE COMMUNICATIONS - PHYSICAL LAYER INTERFACE - CABLE CONNECTED
AAMI NS28 : 1988 : R2015 INTRACRANIAL PRESSURE MONITORING DEVICES
DKD-R 4-1:2018 BLOOD PRESSURE TRANSDUCERS
AAMI BP22 : 1994 : R2011 BLOOD PRESSURE TRANSDUCERS
EEE 602 : 2007 ELECTRIC SYSTEMS IN HEALTH CARE FACILITIES
AAMI NS28 : 1988 : R2010 INTRACRANIAL PRESSURE MONITORING DEVICES
IEEE DRAFT 1073.2 : SEP 95 MEDICAL DEVICES COMMUNICATIONS, APPLICATION PROFILES (MDAP) - FRAMEWORK AND OVERVIEW
AAMI EC13 : 2002 CARDIAC MONITORS, HEART RATE METERS AND ALARMS
ANSI/AAMI BP22:1994(2016) BLOOD PRESSURE TRANSDUCERS
ASTM F 1456 : 2001 Standard Specification for Minimum Performance and Safety Requirements for Capnometers
AAMI NS28 : 1988 : R2006 INTRACRANIAL PRESSURE MONITORING DEVICES
AAMI RD5 : 2003 HEMODIALYSIS SYSTEMS
AAMI EC11 : 1991 DIAGNOSTIC ELECTROCARDIOGRAPHIC DEVICES
AAMI DF2 : 3ED 96 CARDIAC DEFIBRILLATOR DEVICES
ANSI S3.39 : 1987 : R2007 SPECIFICATIONS FOR INSTRUMENTS TO MEASURE AURAL ACOUSTIC IMPEDANCE AND ADMITTANCE (AURAL ACOUSTIC IMMITTANCE)
ASTM F 1452 : 2001 Standard Specification for Minimum Performance and Safety Requirements for Anesthetic Gas Monitors
ANSI/ASA S3.39 : 1987(R2012) SPECIFICATIONS FOR INSTRUMENTS TO MEASURE AURAL ACOUSTIC IMPEDANCE AND ADMITTANCE (AURAL ACOUSTIC IMMITTANCE)

View more information
Sorry this product is not available in your region.