• There are no items in your cart

AAMI ISO TIR 10974 : 2012

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

ASSESSMENT OF THE SAFETY OF MAGNETIC RESONANCE IMAGING FOR PATIENTS WITH AN ACTIVE IMPLANTABLE MEDICAL DEVICE
Available format(s)

Hardcopy , PDF

Superseded date

05-27-2018

Language(s)

English

Published date

01-01-2012

Glossary of equivalent standards
Committee representation
Background of the AAMI adoption of ISO TS 10974:2018
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 General requirements for non-implantable parts
6 Requirements for particular AIMDs
7 General considerations for application of the
   tests of this document
8 Protection from harm to the patient caused by
   RF-induced heating
9 Protection from harm to the patient caused by
   gradient-induced device heating
10 Protection from harm to the patient caused by
   gradient-induced vibration
11 Protection from harm to the patient caused by
   B[0]-induced force
12 Protection from harm to the patient caused by
   B[0]-induced torque
13 Protection from harm to the patient caused by
   gradient-induced extrinsic electric potential
14 Protection from harm to the patient caused by
   B[0]-induced malfunction
15 Protection from harm to the patient caused by
   RF-induced malfunction and RF rectification
16 Protection from harm to the patient caused by
   gradient-induced malfunction
17 Combined fields test
18 Markings and accompanying documentation
Annex A (normative) - Pulsed gradient exposure
        for Clause 10, Clause 13, and Clause 16
Annex B (informative) - Derivation of lead length
        factor for injected voltage test levels for
        Clause 13 and Clause 16
Annex C (informative) - Tier 1 high tangential E-field
        trough line resonator
Annex D (informative) - Supporting information and
        rationale for gradient-induced device
        heating
Annex E (informative) - Example RF injection network
Annex F (informative) - Supporting information and
        rationale for MR-induced vibration
Annex G (informative) - Gradient vibration patent
        declaration form
Annex H (informative) - Assessment of dielectric and
        thermal parameters
Annex I (informative) - RF exposure system validation
        method
Annex J (informative) - MR scanner RF transmit coil
Annex K (informative) - Current distribution on the AIMD
        as a function of the phase distribution
        of the incident field
Annex L (informative) - Tissue simulating medium formulations
Annex M (informative) - Generation of incident fields
Annex N (informative) - Dielectric and thermal tissue properties
Annex O (informative) - Gradient field injected testing - AIMD
        electrode tissue impedance determination method
Annex P (informative) - Estimation of conservative B[1] and 10 g
        averaged E-field values for Tier 1 for
        RF-induced heating and RF malfunction
Annex Q (informative) - AIMD configuration
Annex R (informative) - Electrically excitable tissue stimulation,
        terms and definitions
Annex S (informative) - Combined fields test
Annex T (informative) - General methods for modelling dB/dt
        levels in MR gradient coils
Bibliography

Pertains to implantable parts of active implantable medical devices (AIMDs) intended to be used in patients who undergo a magnetic resonance scan in 1,5 T, cylindrical (circular or elliptical cross-section) bore, whole body MR scanners operating at approximately 64 MHz with whole body coil excitation.

DocumentType
Standard
Pages
224
PublisherName
Association for the Advancement of Medical Instrumentation
Status
Superseded
SupersededBy

Standards Relationship
ISO/TS 10974:2012 Identical

ASTM F 2503 : 2013 : REDLINE Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment
IEC 60601-2-33:2010+AMD1:2013+AMD2:2015 CSV Medical electrical equipment - Part 2-33: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis
IEEE C95.3-2002 IEEE Recommended Practice for Measurements and Computations of Radio Frequency Electromagnetic Fields With Respect to Human Exposure to Such Fields, 100 kHz-300 GHz
ASTM F 2052 : 2015 : REDLINE Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment
ISO 14708-1:2014 Implants for surgery — Active implantable medical devices — Part 1: General requirements for safety, marking and for information to be provided by the manufacturer
ASTM F 2213 : 2017 : REDLINE Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment
ISO 5841-3:2013 Implants for surgery — Cardiac pacemakers — Part 3: Low-profile connectors (IS-1) for implantable pacemakers
ISO 27186:2010 Active implantable medical devices Four-pole connector system for implantable cardiac rhythm management devices - Dimensional and test requirements
ISO 14971:2007 Medical devices Application of risk management to medical devices

View more information
US$293.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.