• There are no items in your cart

ACI 355.2 : 2007

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

QUALIFICATION OF POST-INSTALLED MECHANICAL ANCHORS IN CONCRETE AND COMMENTARY
Available format(s)

Hardcopy , PDF

Superseded date

07-06-2019

Language(s)

English

Published date

01-01-2007

STANDARD:
Chapter 1 - Scope
Chapter 2 - Definitions and notation
Chapter 3 - Significance and use
Chapter 4 - General requirements
Chapter 5 - Requirements for test specimens,
            installing anchors, and conducting
            tests
Chapter 6 - Requirements for anchor identification
Chapter 7 - Reference tests
Chapter 8 - Reliability tests
Chapter 9 - Service-condition tests
Chapter 10 - Establishing anchor categories
Chapter 11 - Presenting anchor data
Chapter 12 - Requirements for independent testing and
             evaluation agency
Chapter 13 - References
MANDATORY APPENDIXES:
Appendix A1 - Requirements for normalization of results
Appendix A2 - Requirements for establishing characteristic
              capacities
Appendix A3 - Requirements for test members
COMMENTARY:
Chapter R1 - Scope
Chapter R2 - Definitions and notation
Chapter R3 - Significance and use
Chapter R4 - General requirements
Chapter R5 - Requirements for test specimens, installing
             anchors, and conducting tests
Chapter R6 - Requirements for anchor identification
Chapter R7 - Reference tests
Chapter R8 - Reliability tests
Chapter R9 - Service-condition tests
Chapter R11 - Presenting anchor data
Chapter R13 - References
Appendix RA1 - Requirements for normalization of results
EXAMPLE EVALUATION OF A WEDGE-TYPE ANCHOR IN UNCRACKED
CONCRETE:
E1 - Anchor specifications
E2 - Test results
E3 - Evaluation
E4 - Establishing anchor category
E5 - Report of anchor data

Prescribes testing programs and evaluation requirements for post-installed mechanical anchors intended for use in concrete under the design provisions of ACI 318. Criteria are prescribed for determining whether anchors are acceptable for use in uncracked concrete only, or in cracked as well as uncracked concrete. Performance categories for anchors are established, as are the criteria for assigning anchors to each category.

Committee
355
DocumentType
Standard
Pages
39
PublisherName
American Concrete Institute
Status
Superseded
SupersededBy

CSA S832 : 2014 SEISMIC RISK REDUCTION OF OPERATIONAL AND FUNCTIONAL COMPONENTS (OFCS) OF BUILDINGS
ACI 551.2R : 2015 DESIGN GUIDE FOR TILT-UP CONCRETE PANELS
ACI 351.2R : 2010 REPORT ON FOUNDATIONS FOR STATIC EQUIPMENT
ASCE 7 05 : 2006 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
A23.3-14 Design of concrete structures
ASCE 7 10 : 2011 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
UFC 3-310-04 : Change 1 UNIFIED FACILITIES CRITERIA - SEISMIC DESIGN FOR BUILDINGS
ACI 369R : 2011 GUIDE FOR SEISMIC REHABILITATION OF EXISTING CONCRETE FRAME BUILDINGS AND COMMENTARY
ACI 318M : 2014 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318M-14) AND COMMENTARY (ACI 318RM-14)
ACI 350M : 2006 METRIC CODE REQUIREMENTS FOR ENVIRONMENTAL ENGINEERING CONCRETE STRUCTURES AND COMMENTARY
ACI 350 : 2006 CODE REQUIREMENTS FOR ENVIRONMENTAL ENGINEERING CONCRETE STRUCTURES AND COMMENTARY
ACI PRC-506 : 2016 GUIDE TO SHOTCRETE
FM 1951,52,53 : 2016 PIPE HANGER COMPONENTS FOR AUTOMATIC SPRINKLER SYSTEMS
ACI MNL 3 : 0 GUIDE TO THE CODE FOR ASSESSMENT, REPAIR, AND REHABILITATION OF EXISTING CONCRETE STRUCTURES
ACI 355.4 : 2011 QUALIFICATION OF POST-INSTALLED ADHESIVE ANCHORS IN CONCRETE AND COMMENTARY
ACI 369.1M : 2017 STANDARD REQUIREMENTS FOR SEISMIC EVALUATION AND RETROFIT OF EXISTING CONCRETE BUILDINGS (ACI 369.1M-17) AND COMMENTARY
ACI 562 : 2016 CODE REQUIREMENTS FOR ASSESSMENT, REPAIR, AND REHABILITATION OF EXISTING CONCRETE STRUCTURES AND COMMENTARY
ASCE/SEI 41 13 : 2014 SEISMIC EVALUATION AND RETROFIT OF EXISTING BUILDINGS
API 1615 : 2011 INSTALLATION OF UNDERGROUND PETROLEUM STORAGE SYSTEMS
ACI 355.3R : 2011 GUIDE FOR DESIGN OF ANCHORAGE TO CONCRETE: EXAMPLES USING ACI 318 APPENDIX D
ACI 355.4M : 2011 QUALIFICATION OF POST-INSTALLED ADHESIVE ANCHORS IN CONCRETE AND COMMENTARY (METRIC VERSION)
N287.2-17 Material requirements for concrete containment structures for nuclear power plants
ACI 318 : 2014 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY
API 1615 REDLINE : 2011 INSTALLATION OF UNDERGROUND PETROLEUM STORAGE SYSTEMS

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
ACI 318 : 2014 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY
ACI 318R : 1995 COMMENTARY ON BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE
ASTM C 42/C 42M : 2016-10 TEST METHOD FOR OBTAINING AND TESTING DRILLED CORES AND SAWED BEAMS OF CONCRETE
ISO/IEC 17011:2004 Conformity assessment General requirements for accreditation bodies accrediting conformity assessment bodies
ASTM E 488 : 1996 Standard Test Methods for Strength of Anchors in Concrete and Masonry Elements
ACI 224R : 2001 CONTROL OF CRACKING OF CONCRETE STRUCTURES
ANSI B212.15 : 1994(R2000) CUTTING TOOLS - CARBIDE-TIPPED MASONRY DRILLS AND BLANKS FOR CARBIDE-TIPPED MASONRY DRILLS

View more information
US$62.50
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.