AS 1807.6-1989

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Cleanrooms, workstations and safety cabinets - Methods of test Determination of integrity of terminally mounted HEPA filter installations
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

02-23-2023

Language(s)

English

Published date

01-01-1989

This Standard, together with the other Standards under AS 1807, sets out a series of methods. The specifications for all test equipment have been incorporated in the series and additional test methods for testing safety cabinets and determining the recovery times of cleanrooms have been included. The test method in AS 1807.7-1976 has been replaced by a method to test the installation integrity of not terminally mounted HEPA filters which is based on the test method in AS 1132.9-1973, and the test method in AS 1807.14-1976 has been incorporated in Methods 12 and 13 and withdrawn without replacement.

This Standard sets out the method for determining the overall integrity of a terminally mounted HEPA filter installation in a cleanroom, workstation, or safety cabinet.NOTE: A test method for determination of the overall integrity of HEPA filter installations which are not terminally mounted is specified in AS 1807.7.

Committee
ME-060
DocumentType
Standard
ISBN
0 7262 5707 9
Pages
2
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

Under Revision See DR 98145

AS/NZS 4273(INT):1995 Guidelines for the design, installation and use of pharmaceutical isolators
AS 2567-1994 Laminar flow cytotoxic drug safety cabinets
AS 4273-1999 Design, installation and use of pharmaceutical isolators
AS 4260.2(INT)-1994 High efficiency particulate air (HEPA) filters Methods of test
AS 2252.1-1994 Biological safety cabinets - Biological safety cabinets (Class I) for personnel and environment protection
AS/NZS 2982.1:1997 Laboratory design and construction General requirements
AS 2252.2-1994 Biological safety cabinets - Laminar flow biological safety cabinets (Class II) for personnel, environment and product protection
AS 4260.1(INT)-1994 High efficiency particulate air (HEPA) filters Performance and construction
AS 4260-1997 High efficiency particulate air (HEPA) filters - Classification, construction and performance (Reconfirmed 2018)
AS/NZS 2243.3:1995 Safety in laboratories Microbiology

View more information
US$15.94
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.