    Maintenance of fire protection equipment - Management procedures for maintaining the fire and smoke control features of air-handling systems

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  01-20-2020

    Language(s):  English

    Published date:  01-01-1997

    Publisher:  Standards Australia

    Add to Watchlist

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS 1851.6-1997 MAINTENANCE OF FIRE PROTECTION EQUIPMENT - MANAGEMENT PROCEDURES FOR MAINTAINING THE FIRE AND SMOKE CONTROL FEATU
    4 - PREFACE
    5 - CONTENTS
    6 - SECTION 1 SCOPE AND GENERAL
    6 - 1.1 SCOPE
    6 - 1.2 APPLICATION
    6 - 1.3 REFERENCED DOCUMENTS
    7 - 1.4 DEFINITIONS
    7 - 1.4.1 Automatic activation
    7 - 1.4.2 Competent person
    7 - 1.4.3 Maintenance
    7 - 1.4.4 Maintenance program
    7 - 1.4.5 Maintenance report
    7 - 1.4.6 Simulated activation
    7 - 1.4.7 Specified performance
    7 - 1.4.8 Testing
    8 - SECTION 2 MAINTENANCE PROGRAM
    8 - 2.1 GENERAL
    8 - 2.2 IMPLEMENTATION
    8 - 2.3 FOLLOW-UP ACTION
    8 - 2.3.1 General
    8 - 2.3.2 Programming
    8 - 2.3.3 Corrective action
    8 - 2.3.4 Recommissioning
    8 - 2.3.5 Updating of records
    9 - SECTION 3 MAINTENANCE ROUTINES
    9 - 3.1 GENERAL
    9 - 3.2 LEVELS OF MAINTENANCE
    9 - 3.3 FREQUENCY
    9 - 3.3.1 Level 1 routines
    9 - 3.3.2 Levels 2, 3 and 4 routines
    10 - 3.4 PERFORMANCE MEASUREMENTS
    11 - SECTION 4 MAINTENANCE DOCUMENTATION
    11 - 4.1 GENERAL
    11 - 4.2 OPERATING AND MAINTENANCE MANUALS
    11 - 4.3 MAINTENANCE SCHEDULE
    11 - 4.4 PLANT REGISTER
    11 - 4.5 PLANT HISTORY RECORD
    12 - 4.6 MAINTENANCE RECORDS
    12 - 4.7 AVAILABILITY OF MANUALS AND RECORDS
    12 - 4.8 EVIDENCE OF COMPLIANCE
    13 - APPENDIX A - RECOMMENDED FREQUENCIES OR CONDITIONS FOR LEVELS 2, 3 AND 4 ROUTINES
    14 - APPENDIX B - TYPICAL INSPECTION AND MAINTENANCE ROUTINES
    14 - B1 GENERAL
    14 - B2 FANS
    14 - B2.1 Level 1
    14 - B2.2 Level 2
    14 - B2.3 Level 3
    14 - B2.4 Level 4
    15 - B3 MOTORS, INDUCTION
    15 - B3.1 Level 1
    15 - B3.2 Level 2
    15 - B3.3 Level 3
    15 - B3.4 Level 4
    15 - B4 FIRE DAMPERS
    15 - B4.1 Level 1
    15 - B4.2 Level 2
    15 - B4.3 Level 3
    15 - B4.4 Level 4
    16 - B5 FIRE MODE AIR DAMPERS FOR SMOKE-SPILL, FRESH AIR AND RECYCLE AIR, COMPLETE WITH THEIR AUTOMATIC CONTROL GEAR
    16 - B5.1 Level
    16 - B5.2 Level 2
    16 - B5.3 Level 3
    16 - B6 AIR FILTERS
    16 - B6.1 Level 1
    16 - B6.2 Level 2
    16 - B6.3 Level 3
    16 - B6.4 Level 4
    16 - B7 ELECTRIC DUCT HEATERS
    16 - B7.1 Level 1
    17 - B7.2 Level 2
    17 - B7.3 Level 3
    17 - B7.4 Level 4
    17 - B8 KITCHEN EXHAUST SYSTEMS
    17 - B8.1 Level 1
    17 - B8.2 Level 2
    17 - B8.3 Level 3
    17 - B8.4 Level 4
    17 - B9 AIR-HANDLING CHANGE OVER UNDER FIRE/SMOKE CONDITIONS
    17 - B9.1 Level 1
    18 - B9.2 Level 2
    18 - B9.3 Level 3
    18 - B9.4 Level 4
    18 - B10 FIRE-ISOLATED ESCAPE ROUTES PROTECTED BY AIR- PRESSURIZATIONSYSTEMS
    18 - B10.1 Level 1
    19 - B10.2 Level 2
    19 - B10.3 Level 3
    20 - B10.4 Level 4
    20 - B11 OUTDOOR AIR INTAKES
    20 - B11.1 Level 1
    20 - B11.2 Level 2

    Abstract - (Show below) - (Hide below)

    Specifies management procedures for controlling the inspection and testing of required fire and smoke control features associated with air-handling systems in buildings, to ensure their effective availability. Mandatory requirements for the frequency of simple inspections are laid down as Level 1 routines. Informative recommendations for more complex and detailed inspections are laid down in Levels 2, 3 and 4.

    Scope - (Show below) - (Hide below)

    This Standard specifies management procedures for controlling the inspection and testing of required fire and smoke control features associated with air-handling systems in buildings, to ensure their effective availability.NOTES:1 The procedures set out in this Standard and all consequential corrective actions, preferably, should be carried out, or at least be supervised, by competent personnel.2 In the assessing of the need for corrective action, regard should be given to the various factors which may affect the precise performance from day to day. For this reason, critical limits of performance will need to be known. In this context a critical limit sets the level of a performance characteristic beyond which its effect could become detrimental to life safety.3 It is recommended that the management system developed for the maintenance of the fire-precaution features of the air-handling systems is integrated with the management systems developed for other associated building services such as lifts, smoke detection systems, fire suppression systems and emergency power systems to create an integrated maintenance management system.

    General Product Information - (Show below) - (Hide below)

    Committee ME-062
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    Under Revision see DR 03188 First published as AS 1851.6-1983.
    Second edition 1997. First published as AS 1851.6-1983. Second edition 1997.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 2676.2-1992 Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Sealed cells
    AS 1668.1-1991 The use of mechanical ventilation and air-conditioning in buildings - Fire and smoke control
    AS 1851.5-1981 Maintenance of fire protection equipment - Automatic smoke/heat venting systems
    AS 1851.3-1985 Maintenance of fire protection equipment - Automatic fire sprinkler systems
    AS 1851.7-1984 Maintenance of fire protection equipment - Fire-resistant doorsets
    AS 1851.10-1989 Maintenance of fire protection equipment - Emergency warning and intercommunication systems
    AS 1851.8-1987 Maintenance of fire protection equipment - Automatic fire detection and alarm systems
    AS 2676.1-1992 Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Vented cells

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 4429(INT)-1996 Methods of test and rating requirements for smoke-spill fans
    AS/NZS 3666.2:1995 Air-handling and water systems of buildings - Microbial control - Operation and maintenance
    AS 1470-1986 Health and safety at work - Principles and practices
    AS 60849-2004 Sound systems for emergency purposes (IEC 60849:1998 MOD)
    AS 1682.1-1990 Fire dampers Specification
    AS 1940-2004 The storage and handling of flammable and combustible liquids
    AS/NZS 1668.1:1998 The use of ventilation and airconditioning in buildings Fire and smoke control in multi-compartment buildings
    AS 4655-2005 Fire safety audits
    AS/NZS 3666.1:2002 Air-handling and water systems of buildings - Microbial control - Design, installation and commissioning
    AS 4429-1999 Methods of test and rating requirements for smoke-spill fans
    SAA/SNZ HB32:1995 Control of microbial growth in air-handling and water systems in buildings (Reconfirmed 2016)
    AS/NZS 3666.2:2002 Air-handling and water systems of buildings - Microbial control Operation and maintenance
    AS 1668.3-2001 The use of ventilation and airconditioning in buildings Smoke control systems for large single compartments or smoke reservoirs
    AS 3962-2001 Guidelines for design of marinas
    AS/NZS 3666.1:1995 Air-handling and water systems of buildings - Microbial control - Design, installation and commissioning
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective