• There are no items in your cart

AS 1851.8-1987

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Maintenance of fire protection equipment - Automatic fire detection and alarm systems

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

06-23-2021

Language(s)

English

Published date

01-01-1987

1 - AS 1851.8-1987 MAINTENANCE OF FIRE PROTECTION EQUIPMENT - AUTOMATIC FIRE DETECTION AND ALARM SYSTEMS
4 - PREFACE
4 - CONTENTS
5 - SECTION 1. SCOPE AND GENERAL
5 - 1.1 SCOPE.
5 - 1.2 REFERENCED DOCUMENTS.
5 - 1.3 DEFINITIONS.
6 - SECTION 2. GENERAL REQUIREMENTS
6 - 2.1 MAINTENANCE OF INSTALLATION.
6 - 2.2 RECORDS.
6 - 2.3 INSPECTION, TESTING , AND MAINTENANCE PRECAUTIONS.
7 - SECTION 3. MAINTENANCE PROCEDURES
7 - 3.1 WEEKLY.
7 - 3.2 MONTHLY.
7 - 3.3 YEARLY.
8 - SECTION 4. MAINTENANCE DOCUMENTATION
8 - 4.1 GENERAL.
8 - 4.2 LOGBOOK.
9 - APPENDIX A - LOGBOOK REPORT
10 - APPENDIX B - FIRE DETECTOR TESTERS
10 - B1 SCOPE.
10 - B2 REQUIREMENTS.
11 - APPENDIX C - DETECTOR TEST RECORD

Specifies requirements for the regular maintenance, including inspection and testing procedures, for fire detection and alarm systems designed and installed in accordance with AS 1670. Maintenance procedures are given for three levels of service, weekly, monthly, and yearly. Appendices set out requirements for fire detectors, and the formats required for logbook reports and detector test records.

This standard sets out requirements for the regular maintenance of automatic fire detection and alarm systems designed and installed in accordance with AS 1670. Regular maintenance includes inspection and testing procedures.Although this standard has direct relevance to systems designed and installed in accordance with AS 1670, the Standard may be used as a basis for maintenance of other automatic fire detection and alarm systems.

Committee
FP-001
DocumentType
Standard
ISBN
0 7262 4668 9
Pages
7
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Under Revision see DR 03188

AS 60849-2004 Sound systems for emergency purposes (IEC 60849:1998 MOD)
AS 1851.3-1997 Maintenance of fire protection equipment Automatic fire sprinkler systems
AS 1851.3-1997 Maintenance of fire protection equipment Automatic fire sprinkler systems
AS 1894-1997 The storage and handling of non-flammable cryogenic and refrigerated liquids (Reconfirmed 2021)
AS 1940-2004 The storage and handling of flammable and combustible liquids
AS 1670.1-1995 Fire detection, warning, control and intercom systems - System design, installation and commissioning Fire
AS 4655-2005 Fire safety audits
AS 1851.12-1995 Maintenance of fire protection equipment - Gaseous fire extinguishing systems
AS 1851.6-1997 Maintenance of fire protection equipment - Management procedures for maintaining the fire and smoke control features of air-handling systems
AS 1603.16-2002 Automatic fire detection and alarm systems - In situ testers
AS/NZS 1851.16:1997 Maintenance of fire protection equipment Pyrogen fire extinguishing aerosol systems
AS/NZS 2927:2001 The storage and handling of liquefied chlorine gas
AS 3962-2001 Guidelines for design of marinas
AS 1670.1-2004 Fire detection, warning, control and intercom systems - System design, installation and commissioning Fire

View more information
US$26.49
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.