• There are no items in your cart

AS 2567-1994

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Laminar flow cytotoxic drug safety cabinets
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

08-01-2017

Language(s)

English

Published date

01-01-1994

1 - AS 2567-1994 LAMINAR FLOW CYTOTOXIC DRUG SAFETY CABINETS
4 - PREFACE
4 - CONTENTS
5 - FOREWORD
6 - 1 SCOPE
6 - 2 REFERENCED DOCUMENTS
7 - 3 GENERAL REQUIREMENTS
7 - 4 CONSTRUCTION REQUIREMENTS
7 - 4.1 Outer shell
7 - 4.2 Work zone
12 - 4.3 Filters and filter installations
13 - 4.4 Blowers and alarm systems
13 - 4.5 Access panels
13 - 4.6 Electrical services
14 - 4.7 Germicidal ultraviolet lamps
14 - 4.8 Post-use overrun control
14 - 5 PERFORMANCE REQUIREMENTS
14 - 5.1 Critical for cabinet functions
15 - 5.2 Other requirements
15 - 6 MARKING

Specifies requirements for open-fronted laminar flow cytotoxic drug safety cabinets intended to provide protection for personnel, the environment and cytotoxic drug products, and possibly for other hazardous drugs and materials. These cabinets are not intended to provide complete protection against particles ejected during tablet crushing and grinding procedures.

This Standard specifies requirements for open-fronted laminar flow cytotoxic drug safety cabinets which are intended to provide protection for personnel, the environment, and cytotoxic drug products. These cabinets may also find wider application for handling other hazardous drugs and materials (see AS 2639). They are primarily designed to contain aerosols, and are not intended to provide complete protection against particles which may be ejected during procedures such as tablet crushing and grinding.This Standard should be read in conjunction with AS 2639 which describes recommended practices for installation and use of these cabinets.

Committee
ME-060
DocumentType
Standard
ISBN
0 7262 8821 7
Pages
10
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

Under Revision see DR 00214 First published as AS 2567-1982.Second edition 1994. First published as AS 2567-1982. Second edition 1994.

AS 1807.5-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of work zone integrity
AS 1807.2-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of performance of clean workstations and laminar flow safety cabinets under loaded filter conditions
AS 2107-1987 Acoustics - Recommended design sound levels and reverberation times for building interiors
AS 1807.22-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of air barrier containment of laminar flow safety cabinets
AS 1807.18-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of vibration in workstations and safety cabinets
AS 3100-1990 Approval and test specification - General requirements for electrical equipment
AS 1319-1994 Safety signs for the occupational environment (Reconfirmed 2018)
AS 1807.1-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of air velocity and uniformity of air velocity in clean workstations and laminar flow safety cabinets
AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)
AS 1132.4-1973 Methods of test for air filters for use in air conditioning and general ventilation Arrestance efficiency, average arrestance efficiency, dust-holding capacity, and dust-holding capacity per unit of effective face area for test dust No 4
AS 3000-1986 Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules)
AS 2647-1994 Biological safety cabinets - Installation and use
AS 2659.1-1988 Guide to the use of sound measuring equipment - Portable sound level meters
AS 2639-1994 Laminar flow cytotoxic drug safety cabinets - Installation and use
AS 1324-1973 Air filters for use in air conditioning and general ventilation
AS 1807.6-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of integrity of terminally mounted HEPA filter installations
AS 1807.15-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of illuminance

AS/NZS 2243.3:2002 Safety in laboratories Microbiological aspects and containment facilities
AS/NZS 4273(INT):1995 Guidelines for the design, installation and use of pharmaceutical isolators
AS 2647-1994 Biological safety cabinets - Installation and use
AS/NZS 2243.1:1997 Safety in laboratories - General
AS/NZS 4020:1999 Products for use in contact with drinking water
AS 4273-1999 Design, installation and use of pharmaceutical isolators
AS 2639-1994 Laminar flow cytotoxic drug safety cabinets - Installation and use
AS 2252.1-1994 Biological safety cabinets - Biological safety cabinets (Class I) for personnel and environment protection
AS/NZS 2647:2000 Biological safety cabinets - Installation and use
AS 2252.2-1994 Biological safety cabinets - Laminar flow biological safety cabinets (Class II) for personnel, environment and product protection
AS/NZS 2243.3:1995 Safety in laboratories Microbiology
AS 1807.22-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air barrier containment of laminar flow safety cabinets

View more information
US$34.90
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.