1 - AS 4085:1992 AUTOMATIC SLIDING DOOR ASSEMBLIES
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 - SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 APPLICATION
6 - 1.3 REFERENCED DOCUMENTS
6 - 1.4 DEFINITIONS
6 - 1.4.1 Actuator
6 - 1.4.2 Clear opening
6 - 1.4.3 Detector
6 - 1.4.4 Detection zone
7 - 1.4.5 Door
7 - 1.4.6 Door hardware
7 - 1.4.7 Door leaf
7 - 1.4.8 Door set
7 - 1.4.9 Emergency condition
7 - 1.4.10 Failsafe
7 - 1.4.11 Frame
7 - 1.4.12 Framed door
7 - 1.4.13 Fully open
7 - 1.4.14 Guides
7 - 1.4.15 Hangers
7 - 1.4.16 Leading edge
7 - 1.4.17 Lintel
7 - 1.4.18 Loading
7 - 1.4.19 Mullion
7 - 1.4.20 Operator
7 - 1.4.21 Operating cycle
7 - 1.4.22 Overall opening
7 - 1.4.23 Pelmet
7 - 1.4.24 Permanent frame
7 - 1.4.25 Transom assembly
7 - 1.4.26 Trailing edge
7 - 1.4.27 Unframed door
7 - 1.4.28 Velocity
8 - 1.5 DUTY RATING
9 - SECTION 2 - DOOR SETS
9 - 2.1 MATERIALS
9 - 2.1.1 General
9 - 2.1.2 Aluminium
9 - 2.1.3 Glass
9 - 2.1.4 Steel
9 - 2.1.5 Timber
9 - 2.2 LOADS
9 - 2.2.1 General
9 - 2.2.2 Vertical loads
9 - 2.2.3 Lateral loads
9 - 2.2.4 Racking loads
9 - 2.3 PERMANENT FRAME AND SUPPORT SYSTEMS
9 - 2.3.1 General
10 - 2.3.2 Fixings
10 - 2.3.3 Mullions
10 - 2.3.4 Lintels
10 - 2.3.5 Operators and transom assemblies
10 - 2.3.6 Fixed panels
10 - 2.4 DOORS AND DOOR HARDWARE
10 - 2.4.1 General
10 - 2.4.2 Door leaf frames
12 - 2.4.3 Hangers
12 - 2.4.4 Bottom guides
12 - 2.4.5 Door hardware
12 - 2.4.6 Indicator sign
13 - 2.5 OPERATION
13 - 2.5.1 General
13 - 2.5.2 Limits of travel
14 - SECTION 3 - ACTUATORS
14 - 3.1 PERFORMANCE CHARACTERISTICS
14 - 3.1.1 General
14 - 3.1.2 Kinetic energy limitation
14 - 3.1.3 Holding force
14 - 3.1.4 Ambient conditions
14 - 3.2 INSTALLATION
14 - 3.2.1 General
14 - 3.2.2 Electrical installation
15 - SECTION 4 - DETECTORS
15 - 4.1 DETECTOR FUNCTIONS
15 - 4.1.1 General
15 - 4.1.2 Detector types
15 - 4.1.3 Detection zone
15 - 4.2 PRESSURE MATS
15 - 4.2.1 Materials
15 - 4.2.2 Detection zone
15 - 4.2.3 Performance characteristics
15 - 4.2.4 Installation
15 - 4.3 PHOTO-ELECTRIC DETECTORS
15 - 4.3.1 General
15 - 4.3.2 Detection zone
16 - 4.3.3 Performance characteristics
16 - 4.3.4 Installation
16 - 4.4 RADIANT ENERGY DETECTORS
16 - 4.4.1 General
16 - 4.4.2 Detection zone
17 - 4.4.3 Performance characteristics
17 - 4.4.4 Installation
17 - 4.4.4.1 Physical
17 - 4.4.4.2 Electrical
17 - 4.5 SAFETY DETECTORS
18 - SECTION 5 - CONTROL SYSTEMS
18 - 5.1 GENERAL
18 - 5.2 OPERATING REQUIREMENTS
18 - 5.3 REQUIRED EXIT DOORS
18 - 5.3.1 Application
18 - 5.3.2 Operation
18 - 5.3.3 Low battery warning device
18 - 5.4 SECURITY CONTROL
19 - SECTION 6 - INSTALLATION AND COMMISSIONING
19 - 6.1 GENERAL
19 - 6.2 INSTALLATION OF COMPONENTS
19 - 6.2.1 Permanent frame
19 - 6.2.2 Operator
19 - 6.2.3 Fixed panels
19 - 6.2.4 Doors
19 - 6.2.5 Bottom guides
19 - 6.2.6 Other components
19 - 6.3 ELECTRICAL INSTALLATION
19 - 6.3.1 General
19 - 6.3.2 Wiring recommendations
19 - 6.3.3 Building emergency alarm system
19 - 6.4 COMMISSIONING
19 - 6.4.1 Adjustment of components
20 - 6.4.2 Commissioning operation
20 - 6.4.3 Commissioning report
20 - 6.4.4 System identification
21 - APPENDIX A - RECOMMENDED AUTOMATIC SLIDING DOOR INSPECTION AND MAINTENANCE PROCEDURES
21 - A1 INTRODUCTION
21 - A2 OPERATIONAL INSPECTION AND MAINTENANCE
21 - A2.1 General
21 - A2.2 Inspection and maintenance frequency
21 - A2.3 Inspection procedure
21 - A3 LOG BOOK
21 - A4 MAINTENANCE PERSONNEL
22 - A5 INSPECTION REPORT

Specifies minimum performance requirements for materials and components of automatic sliding doors and door assemblies. Information is provided on operational safety and durability for ingress and egress traffic when assembled, installed and commissioned. Doors are classified according to hourly operating cycles. Control systems are described for both normal and emergency conditions including positioning and operation of pressure mats, photo-electric and radiant energy detectors as well as detection zone dimensions. An Appendix introduces recommended operational inspection procedures and frequency.

This Standard sets out functional requirements for the materials and components of automatic sliding door assemblies and requirements for operational safety and durability when assembled, installed, and commissioned. The Standard also classifies sliding doors in accordance with a duty rating according to the expected average number of operational cycles.NOTE: Appendix A describes recommended automatic sliding door inspection and maintenance procedures.

Committee
BD-055
DocumentType
Standard
ISBN
0 7262 7891 2
Pages
17
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

First published as AS 4085-1992.

AS 2047-1999 Windows in buildings - Selection and installation
AS 1665-1992 Welding of aluminium structures
AS 1540-1974 Timber frames and sashes for windows
AS/NZS 3679.1:1996 Structural steel Hot-rolled bars and sections
AS 1170.2-1989 Minimum design loads on structures (known as the SAA Loading Code) Wind loads
AS 1288-2006 Glass in buildings - Selection and installation
AS 1735.2-2001 Lifts, escalators and moving walks Passenger and goods lifts - Electric
AS/NZS 1866:1997 Aluminium and aluminium alloys - Extruded rod, bar, solid and hollow shapes (Reconfirmed 2020)
AS 1538-1988 Cold-formed Steel Structures Code
AS 1866-1986 Aluminium and aluminium alloys - Extruded rod, bar, solid and hollow shapes
AS 3000-1986 Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules)
AS 2048-1977 Code of practice for installation and maintenance of aluminium windows in buildings
AS 1288-1994 Glass in buildings - Selection and installation
AS/NZS 3678:1996 Structural steel - Hot-rolled plates, floorplates and slabs
AS 3679.2-1991 Structural steel - Welded sections
AS/NZS 1170.2:2002 Structural design actions Wind actions
AS 3679.1-1990 Structural steel - Hot-rolled bars and sections
AS 3678-1990 Structural steel - Hot-rolled plates, floorplates and slabs
AS/NZS 3679.2:1996 Structural steel - Welded I sections
AS 2796-1985 Timber - Seasoned hardwood - Milled products
AS/NZS 1665:2004 Welding of aluminium structures (Reconfirmed 2016)
AS 1163-1991 Structural steel hollow sections

AS/NZS 1905.1:1997 Components for the protection of openings in fire-resistant walls Fire-resistant doorsets
AS 4290-2000 Design and installation of Revolving doors
AS 4290-2000 Design and installation of Revolving doors
AS 1905.1-2005 Components for the protection of openings in fire-resistant walls Fire-resistant doorsets

View more information
US$60.92
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.